User manual NEWPOL XS 251CO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NEWPOL XS 251CO. We hope that this NEWPOL XS 251CO user guide will be useful to you.

Lastmanuals help download the user guide NEWPOL XS 251CO.


Mode d'emploi NEWPOL XS 251CO
Download
Manual abstract: user guide NEWPOL XS 251CO

Detailed instructions for use are in the User's Guide.

[. . . ] Use the appliance only for its intended purpose. , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Use this appliance only in the manner intended by the manufacturer. appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. properly installed and grounded by a qualified technician. [. . . ] The charcoal filter timer is not preset. Before using the hood in recirculation mode, the charcoal filter timer must be programmed. The indicator for the charcoal filter and one of the "­/+" indicators will flash. The lit indicator shows the programmed time: 1st indicator from the left = 120 hours 2nd indicator from the left = 180 hours 3rd indicator from the left = 240 hours 4th indicator from the left = deactivated ^ Use the "­/+" button to select the desired time. ^ Turn off the fan using the On/Off button. ^ Press the Delayed Shut Down and Charcoal Filter buttons at the same time. ^ Store the selection by pressing the charcoal filter button. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. 16 Cleaning and Care , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Avoid: ­ cleaning agents containing soda, acids, solvents or chlorides, ­ abrasive cleaning agents e. g. powder or cream cleansers, ­ abrasive sponges, e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. ­ limescale removers Cleaning the casing Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ All external surfaces and controls can be cleaned with a mild solution of warm water and liquid dish soap applied with a soft sponge. Do not use too much water when cleaning the controls. Water could penetrate into the electronics and cause damage. ^ Glass surfaces can be cleaned using glass cleaner. These will damage the surface. ^ Once the front edge of the filter is in place, push up the rear of the filter so that both sides click into place. Inserting the decor cover ^ After returning the grease filter, press the grease filter button for 3 seconds to reset the timer. The indicator light will go out. ^ Hook the decor cover on to the latches on the rear panel of the chimney. Push the cover up at the front so that it clicks in place. 19 Cleaning and Care Active charcoal filters In recirculation mode an active charcoal filter must be used in addition to the grease filter. The charcoal filter is designed to absorb cooking odors. Replacement active charcoal filters can be ordered from Miele. ^ The decor cover must be removed to access the active charcoal filter. See "Cleaning and Care". ^ To remove the active charcoal filter pull down on the tab at the back of the filter. ^ Before inserting an active charcoal filter for the first time remove the connector for use in air extraction mode. Loosen the screw in the connector and remove. ^ Insert the new charcoal filter on an angle toward the front of the hood and then firmly press the rear in place. ^ Return the grease filter and decor cover. ^ When the active charcoal filter is installed for the first time, program the charcoal filter timer. [. . . ] ­ If flat ducting is used, the cross section must not be smaller than the cross section of the ventilation exhaust. ­ The ducting should be as short and straight as possible. ­ The exhaust duct must not be bent or compressed. ­ Make sure all connections are secure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEWPOL XS 251CO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NEWPOL XS 251CO will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag