User manual OKI B4600NPS SETUP GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OKI B4600NPS. We hope that this OKI B4600NPS user guide will be useful to you.

Lastmanuals help download the user guide OKI B4600NPS.


Mode d'emploi OKI B4600NPS
Download

You may also download the following manuals related to this product:

   OKI B4600NPS (2475 ko)
   OKI B4600NPS UTILITIES GUIDE (5857 ko)

Manual abstract: user guide OKI B4600NPSSETUP GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Hewlett-Packard, HP and PCL are registered trademarks, and HP LaserJet 4+, HP LaserJet Plus, HP LaserJet II, HP LaserJet IID, HP LaserJet IIID, HP-GL, HPGL/2, and Bi-Tronics are trademarks of Hewlett-Packard Company. IBM, Proprinter XL, Proprinter, and IBM/PC are registered trademarks of International Business Machines Corporation. Intellifont is a registered trademark of AGFA Corporation, a division of Miles, Inc. Microsoft and MS-DOS are registered trademarks of Microsoft Corporation. [. . . ] (Factory setting =ttttt) After you change the input buffer capacity (make sure you press SET switch), be sure to turn off the printer and then turn it on again. The setting takes effect the next time you turn on the printer. Notes · The set capacity is not changed even if the emulation mode is changed. · The actual capacity of the input buffer varies according to the installed RAM. If the RAM capacity is small, the input buffer capacity may not be increased. · When you select duplex printing, it requires more memory to run duplex printing. If you set a large input buffer and the remaining memory is not enough to run duplex printing, the print speed may decrease in duplex printing, the 600dpi resolution may decrease to 300dpi, or the printer may automatically change duplex printing to simplex printing. In such a case, you need to install optional SIMM memory or set a smaller input buffer size in this mode. 4­46 CHAPTER 4 CONTROL PANEL INPUT BUFFER SIZE 14M 15 SQUARES 5 SQUARES 100K 51K 30K 7M 14M 4M 1 SQUARE 30K 26M RAM SIZE Fig. 4-7 Input buffer size SAVE SETTINGS Suppose you share this printer with others who want different panel switch settings or you use the printer with different settings. Since you can save the current settings in the printer's memory, you can easily reset the printer to your necessary settings after they are changed. For resetting the printer, see "RESET Switch" in Chapter 4. Exit To select the font and symbol set in the HP LaserJet 4+ mode, follow these steps: 1. Press the SEL switch to set the printer off-line. The display shows the following menu. PRIMARY FONT 3. Press the v or w switch to select the primary or secondary font setting menu. PRIMARY FONT SECONDARY FONT For this session, select the primary font setting menu. The display shows the font setting menu. You can skip the font setting menu and advance to the symbol set setting menu with the v or w switch. For this session, go to the next step. SELECT FONT p Note The last lowercase letter "p" or "s" indicates the primary or secondary font setting mode. If you select the secondary font setting mode, the display shows "s" in the following messages. 4­50 CHAPTER 4 CONTROL PANEL 5. When you enter the "SELECT FONT" menu, you can select the internal font, optional slot font, or permanent download font. The display shows the following message. INTERNAL FONT p* Press the v or w switch until the desired font source appears on the display. Display Message Font Source Internal font of the printer Optional card font in the upper slot A Optional cartridge font in the lower slot B Permanent download font defined in the HP emulation mode INTERNAL FONT SLOTFONT A SLOTFONT B PERMANENT FONT Since these steps instruct you to select the standard font, select the "INTERNAL FONT" message. [. . . ] Uppercase and lowercase alphabet characters can be accepted. · When Post Net (US-Post Net) is selected with the parameter "t4" or "T4": Characters "0" to "9" can be data and it must be terminated by a check digit. "?" can be used in place of the check digit. Upright (default) Rotated 90 degrees Upside down, rotated 180 degrees Rotated 270 degrees Appendix­70 APPENDICES · When EAN 8, EAN 13, or UPC A is selected with the parameter "t5" or "T5": Ten numerical characters "0" to "9" can be accepted as bar code data. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OKI B4600NPS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OKI B4600NPS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag