User manual OMRON A DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON A. We hope that this OMRON A user guide will be useful to you.

Lastmanuals help download the user guide OMRON A.


Mode d'emploi OMRON A
Download

You may also download the following manuals related to this product:

   OMRON A DATASHEET 2 (486 ko)

Manual abstract: user guide OMRON ADATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] E41515 LR21642 Approved Standard Ratings UL508 (File No. LR21642) Rated voltage 125 VAC 250 VAC 480 VAC 125 VDC 250 VDC 2 HP 20 A 0. 5 A 0. 25 A A-20G 1 HP 10 A "L" F-132 General-purpose Basic Switch A Ratings Rated voltage NC 125 VAC 250 VAC 500 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Note: 1. 20 A 20 A 15 A 20 A 20 A 6A 0. 5 A 0. 25 A Non-inductive load Resistive load NO 7. 5 A 7. 5 A 4A 3A 3A 3A 0. 5 A 0. 25 A 1. 5 A 1. 5 A 1. 5 A NC Lamp load NO 20 A 20 A 10 A 20 A 15 A 5A 0. 05 A 0. 03 A NC Inductive load Inductive load NO NC 12. 5 A 8. 3 A 2A 12. 5 A 12. 5 A 5A 0. 05 A 0. 03 A Motor load NO The above values are for steady-state current. Inductive load has a power factor of 0. 4 min. [. . . ] 2. 3SR (stainless-steel plunger) OP 24. 2 4. 2+0. 075 -0. 025 4. 36+0. 1 dia. -0. 05 11. 9 25. 4±0. 1 49. 2 17. 45+0. 2 9. 2 RF min. OP 3. 92 to 6. 13 N {400 to 625 gf} 2. 79 N {285 gf} 1. 3 mm 0. 25 mm 0. 2 mm 16. 3±0. 4 mm NTLP: Anchored Frames in table above. Short Spring Plunger A-20GD-B PT 19. 05±0. 25 15 dia. 11. 2 dia. 7. 15 dia. OF 11. 9SR (stainlesssteel plunger) OP 7. 5 RF min. OP 3. 92 to 6. 13 N {400 to 625 gf} 2. 79 N {285 gf} 1. 3 mm 3 mm 0. 2 mm 26. 2±0. 5 mm 24. 2 F-134 General-purpose Basic Switch A Panel Mount Plunger A-20GQ-B PT OF 19. 05±0. 25 8. 35 dia. 11. 9SR (stainless-steel plunger) M12 × 1 mounting screw (see note 1) OP (See note 2) 13. 1 Two hexagon nuts (2 t × 14 width across flats) 16 dia. RF min. OP 3. 92 to 6. 13 N {400 to 625 gf} 2. 79 N (285 gf) 1. 3 mm 5. 6 mm 0. 2 mm 21. 8±0. 8 mm 16. 3 Two lock nuts (2 t × 15. 6 width across flats) Note: 1. Do not use both M12 mounting screw and mounting holes at the same time. Imperfect screw part with a maximum length of 1. 5 mm. Panel Mount Roller Plunger A-20GQ22-B PT 19. 05±0. 25 12. 7 dia. × 4. 8 (stainless-steel roller) Two hexagon nuts (3 t × 17 width across flats) OP (See 15. 5 note 2) OF RF min. 2. 75 N {280 gf} 1. 3 mm 3. 58 mm 0. 35 mm 33. 4±1. 2 mm M12 × 1 mounting screw (see note 1) 16 dia. 16. 3 Note: 1. Do not use both M12 mounting screw and mounting holes at the same time. Imperfect screw part with a maximum length of 1. 5 mm. Panel Mount Cross Roller Plunger A-20GQ21-B PT 19. 05±0. 25 12. 7 dia. × 4. 8 (stainlesssteel roller) Two hexagon nuts (3 t × 17 width across flats) OF RF min. OP M12 × 1 mounting screw (see note 1) (See OP 15. 5 note 2) 6. 18 N {630 gf} max. 2. 75 N {280 gf} 1. 3 mm 3. 58 mm 0. 35 mm 33. 4±1. 2 mm 16. 3 16 dia. Note: 1. Do not use both M12 mounting screw and mounting holes at the same time. Imperfect screw part with a maximum length of 1. 5 mm. Short Hinge Lever A-20GV21-B OF 24. 56±0. 25 28. 3R PT 20. 2 17. 9 14. 7 OP t=1 (stainlesssteel lever) 4. 9 RF min. 0. 41 N {42 gf} 6. 5 mm 1. 2 mm 1. 2 mm 19±0. 8 mm General-purpose Basic Switch A F-135 Limit Switches Hinge Lever A-20GV-B 24. 56±0. 25 63. 5R t = 1 (stainless-steel lever) 4. 9 OF RF min. OP 20. 2 17. 9 14. 7 0. 69 N {70 gf} max. [. . . ] If a Switch is side-mounted and secured with screws, make sure that the angle or speed of the actuating object is not excessively large or too high, otherwise the Switch may be damaged. If a Switch is panel-mounted, pay utmost attention to make sure that the actuating speed or OT distance is not excessively high or large. Not doing so may damage the Switch. Accessories (Order Separately) Refer to Z/A/X/DZ Common Accessories for details about Terminal Covers, Separators, and Actuators. General-purpose Basic Switch A F-137 Limit Switches Panel-mounting (A-20GQ@) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag