User manual OMRON A165E DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON A165E. We hope that this OMRON A165E user guide will be useful to you.

Lastmanuals help download the user guide OMRON A165E.


Mode d'emploi OMRON A165E
Download
Manual abstract: user guide OMRON A165EDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] · Features separate construction that allows the Switch to be separated for easier wiring and one-piece-like construction that allows easier handling. · High reliability, IP65 · Short mounting depth, less than 28. 5 mm below panel · Quick and easy assembly, snap-in Switch. · A165E is identifiable, clearly visible and will stop a dangerous process, without creating additional hazards. Model Number Structure Model Number Legend A165E-##-#-# 12 3 4 4. [. . . ] Operating:-10°C to 55°C (with no icing or condensation) Storage:-25°C to 65°C (with no icing or condensation) Operating:35% to 85% Class II 175 3 Approx. 16 g (in case of DPDT Switches) Durability Ambient temperature Ambient humidity Electric shock protection class PTI (tracking characteristic) Degree of contamination Weight Note: LED not mounted. Test them with the LED removed. Operating Characteristics Features Operating force (OF) max. Pretravel (PT) Characteristics 14. 7 N 0. 1 N·m 3. 5±0. 5 mm (3±0. 5 mm In case of A165E#U series) A165E G-285 A165E Nomenclature \ Illumination Colors LED Illumination Red Non-lighted Red Protective Structure and Terminal Type Protective Structure Oil-resistant IP65 Terminal Type Solder terminals (tab terminals #110) Illumination Method LED Lamp LED lamp Switch Specifications Standard Loads 5 A at 125 VAC 3 A at 250 VAC 3 A at 30 VDC Note: A165E Emergency Stop Switch must be ordered as a set. No LED is installed for the non-lighted model. Push-lock, Turn-reset System Prevents Misuse Contact open Safety Lock Prevents Misuse Even if an object or person touches the pushbutton by mistake, the contact will not be released unless the pushbutton reaches the lock position. Contact closed Lock position G-286 Safety Sensors / Components Dimensions Note: All units are in millimeters unless otherwise indicated. A165E Non-lighted models 30 mm diameter 30 dia. Mounting ring 3+0. 1 dia. 0 Packing (T0. 5) Lock ring Lock Note: 1. When applying a coating such as paint to the panel, dimensions after the coating must satisfy the specified dimensions. Recommended panel thickness: 0. 5 to 3. 2 mm. Panel cutout dimensions 16+0. 2 dia. 0 22. 1±0. 8 A165E Lighted models 30 mm diameter 30 dia. Mounting ring Lock ring 7. 8+0. 3 dia. When applying a coating such as paint to the panel, dimensions after the coating must satisfy the specified dimensions. Recommended panel thickness: 0. 5 to 3. 2 mm. Panel cutout dimensions 16+0. 2 dia. 0 22. 1±0. 8 A165E#U One-body models 30 mm diameter 22. 7 30 dia. Mounting ring Note: 1. When applying a coating such as paint to the panel, dimensions after the coating must satisfy the specified dimensions. Recommended panel thickness: 0. 5 to 3. 2 mm. 16+0. 2 dia. 0 Packing (T0. 5) Lock ring Panel cutout dimensions Mounting ring A165E G-287 A165E A165E Non-lighted models 40 mm diameter 40 dia. Mounting ring M16¥1 Switch 0. 5 Packing (T0. 5) Lock ring Lock 7. 8+0. 3 dia. 0 2. 6 1. 4 12. 3 15. 8 18 Note: 1. When applying a coating such as paint to the panel, dimensions after the coating must satisfy the specified dimensions. [. . . ] Rectangular Square Round 15. 6 dia. Screw Fitting t=1 45 dia. A16Z-3004 Lock Ring Rough surface Rough surface 15. 8 ±0. 1 dia. -0. 1 Terminal Arrangement SPST Switches DPST Switches TPST Switches NC2 NC1 12 ¥ 12 Stopper NC3 Note: The L+ and L- terminals are not available with the non-lighted models. A165E G-289 A165E ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON A165E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON A165E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag