Unit Combinations
Non-lighted Pushbutton Switch
Lighted (without Voltage Reduction Unit)
Pushbutton
Lamp LED Incandescent
Switch (without Voltage Reduction Unit)
Lighted (with Voltage Reduction Unit)
Pushbutton
Lamp LED
Switch (with Voltage Reduction Unit)
G-304
Safety Sensors / Components
1. Pushbutton
Lighted/Non-lighted
1 2
A22E#-#
1 Lighted/Non-lighted Code Description 2 Head Size Code MP LP S M L SK MK Description 40 dia. Push-lock key reset Push-lock, turn-reset Push-pull
None Non-lighted L Lighted (see note)
Note: Lighted Emergency Stop Switches are available only for the 40-dia. Lamp
12
A22-##
1 Operating Voltage (Rated Voltage) Incandescent Code 6D 6A 12A 24A LED 6 VDC (6 VDC) 6 VAC (6 VAC) 12 VAC/VDC (12 VAC/VDC) 24 VAC/VDC (24 VAC/VDC) 2 Illumination Color Code R Description Red
3. [. . . ] Since this is not attached to the main body, order separately. "EMERGENCY STOP" is indicated on the plate.
25-dia. black letters on yellow back-ground 90-dia. black letters on yellow back-ground
A22Z-R25
Legend Plates for Emergency Stop
A22Z-3466-1 A22Z-3476-1
Lamp Extractor
A22Z-3901
Rubber tool used to replace Lamps easily Tool used to tighten nuts from the back of the panel
Use to fix the lever on the Switch.
Tightening Tool
---
A22Z-3905
A22Z-3380
Lock Plate
A22E
G-309
A22E
Specifications
Approved Standards
Recognized organization UL (See note. ) AZCO Standards UL508 EN60947-5-1 File No. E41515 C9805502
Note: UL-approved for CSA C22. 2 No. 14 and bears the cR mark.
Approved Standard Ratings
· UL, cUL (File No. E41515) 6 A at 220 V, 10 A at 110 VAC · EN60947-5-1 (Low Voltage Directive) Rated current: 10 A; Rated voltage: 220 VAC
LED Indicators without Voltage Reduction Unit
Rated voltage 6 VDC 6 VAC 12 VAC/VDC 24 VAC/VDC Rated current 60 mA 60 mA 30 mA 15 mA Operating voltage 6 VDC±5% 6 VAC/VDC±5% 12 VAC/VDC±5% 24 VAC/VDC±5%
Ratings
Contacts (Standard Load)
Rated carry current Rated voltage 24 VAC 110 VAC 220 VAC 380 VAC 440 VAC 24 VDC 110 VDC 220 VDC 380 VDC AC15 (inductive load) 10 5 3 2 1 Rated current (A) AC12 DC13 (resistive (inducload) tive load) 10 10 6 --3 2 1. 5 0. 5 --0. 2 0. 1 DC12 (resistive load)
Super-bright LED Indicator
Rated voltage 24 VAC/VDC Rated current 15 mA Operating voltage 24 VAC/VDC ±5%
---
Incandescent Lamp
10 2 0. 6 0. 2 Rated voltage 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC 130 VAC/VDC Rated current 200 mA 80 mA 40 mA 20 mA Operating voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC 100 VAC/VDC
10
---
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the following conditions. (1) Ambient temperature: 20×±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 20 operations/minute 2. Minimum applicable load: 10 mA at 5 VDC
Voltage-reduction Lighting
Rated voltage 110 VAC 220 VAC Operational voltage 95 to 115 VAC 190 to 230 VAC Applicable lamp (BA9S/13# gold) LED Lamp (A22-24A#)
Contacts (Microload)
Rated applicable load 50 mA at 5 VDC (Resistive load) Minimum applicable load 1 mA at 5 VDC
G-310
Safety Sensors / Components
Characteristics
Item Allowable operating frequency Insulation resistance Dielectric strength Vibration resistance Shock resistance Durability Mechanical Malfunction (See note 2. ) Mechanical Electrical Mechanical Electrical Emergency Stop Switches Non-lighted model: A22E Lighted model: A22EL 30 operations/minute max. (at 500 VDC) 2, 500 VAC, 50/60 Hz for 1 min between terminals of same polarity 2, 500 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and ground Malfunction (See note 2. ): 10 to 55 Hz, 1. 5-mm double amplitude 1, 000 m/s2 250 m/s2 max. Momentary operation: 300, 000 operations min. Operating: Operating: -20°C to 55°C -20°C to 70°C Storage: Storage: -40°C to 70°C -40°C to 70°C Operating: 35% to 85% IP65 IP65 (oil-resistant) Class II 175 3 (IEC947-5-1)
Ambient temperature (See note 1. ) Ambient humidity Degree of protection Electric shock protection class PTI (tracking characteristic) Degree of contamination
Note: 1. Malfunction within 1 ms.
Operating Characteristics (for SPST-NO/SPST-NC)
Item Total travel force (TTF) max. Total travel (TT) Releasing force (RF) min. Emergency Stop Switches Push-lock turn-reset system A22E, A22EL 44. 1 N 10±1 mm 0. 25 N·m max. (See note. )
Note: Rotation torque for Emergency Stop Pushbutton.
A22E
G-311
A22E
Nomenclature
Pushbutton Push-lock Turn-reset System Available Color: Red Non-lighted Lighted
Lamp Light source LED Lamp Incandescent Lamp
Switch Contact Ratings 10 A at 110 VAC (resistive load) 10 A at 24 VDC (resistive load) Lighting Method Non-lighted Lighted (without Voltage Reduction Unit) Lighted (with Voltage Reduction Unit)
(The above figures are examples of the lighted model. )
Safety Lock Mechanism to Prevent Misuse
Lock position
This Switch can be intentionally used to stop equipment in an emergency. Even if an object or person touches the Pushbutton by mistake, the contact will not be released unless the Pushbutton reaches the lock position.
This Switch uses a finger protection mechanism to prevent electrical shocks. Moreover, it is provided with a mechanism to prevent terminal screws from coming off and also allows connection to either round or forked crimp terminals.
Finger protection Mechanism for preventing terminal screws from coming off (loosening the screws do not cause them to come off)
G-312
Safety Sensors / Components
Dimensions
Note: All units are in millimeters unless otherwise indicated.
A22E-MP
Non-lighted models 40-dia. Push-pull
A22E-LP
Non-lighted models 60-dia. Push-pull
40 dia.
60 dia.
A22E-S
Non-lighted models 30-dia. [. . . ] Open a hole in the thin rubber section of the rubber ring. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the hexagonal nut to secure the cable.
Lock nut Rubber washer
Connector Tightening cap Cable
Inside
Outside
Box
Cable diameter 7 to 9 dia. 9 to 11 dia.
Connector A22Z-3500-1 A22Z-3500-2
G-318
Safety Sensors / Components
Installing/Removing the Switch Blocks
Installing the Switch Blocks
Hook the small protrusion on the Mounting Latch into the groove on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below.
Wiring
Wiring Round Crimp Terminals
Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direction indicated by the arrow to temporarily secure it. Now, a round crimp terminal can be connected. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON A22E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.