User manual OMRON CIMR-L7Z DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON CIMR-L7Z. We hope that this OMRON CIMR-L7Z user guide will be useful to you.

Lastmanuals help download the user guide OMRON CIMR-L7Z.


Mode d'emploi OMRON CIMR-L7Z
Download

You may also download the following manuals related to this product:

   OMRON CIMR-L7Z QUICK GUIDE (6395 ko)

Manual abstract: user guide OMRON CIMR-L7ZDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] (proporzionale alla tensione di ingresso) 120 Hz max. Trifase; 380, 400, 415, 440, 460 o 480 Vc. a. , 50/60 Hz 13, 2 17 22 32 41 49 + 10%, - 15% 58 78 96 115 154 Alimentazione Corrente nominale di ingresso (A) Fluttuazione di tensione ammessa Fluttuazione di frequenza massima ±5% Opzionale Non previsto Integrata Consentito2 Riduzione delle armoniche 1. Doppio ponte di raddrizzamento La potenza di uscita motore massima applicabile è basata su un motore standard a 4 poli. Selezionare il modello di inverter in base alla corrente nominale di targa del motore. [. . . ] 10 V P +V Alimentazione analogica +15 V 20 mA A1 Ingresso analogico frequenza di riferimento AC 0 . . . 10 V 0V Schede di comunicazione e controllo (opzionali) M3 2CN M4 M5 M6 Inverter pronto (impostazione di fabbrica) Comando contattore (impostazione di fabbrica) MB MC M1 M2 Comando freno (impostazione di fabbrica) Uscite digitali multifunzione 250 Vc. a. , 1A o max. Uscita a contatto di errore 250 Vc. a. , 1A max. 30 Vc. c. , 1 A o max. Regolazione Ingresso analogico 2 K Tensione di ingresso 48/96 Vc. c. da batteria Convertitore c. c/c. c (opzionale) P0 P Alimentazione N0 scheda di controllo Nota 1. I terminali del circuito principale sono indicati da due cerchi e quelli del circuito di comando sono indicati da un solo cerchio. Cavi schermati Cavi schermati a doppini intrecciati Varispeed L7 241 Inverter PG Circuito principale Tensione Modello CIMR-L7Z Potenza di uscita motore massima applicabile R/L1 S/L2 T/L3 R1/L11 S1/L21 20P4 . . . 18, 5 kW 200 V 2022 e 2030 22 e 30 kW 2037 . . . 55 kW Alimentazione ingresso Alimentazione ingresso Alimentazione ingresso Alimentazione ingresso --T1/L31 U/T1 V/T2 W/T3 B1 B2 1 2 3 r / l1 R-R1, S-S1 e T-T1 sono stati collegati prima della consegna --- R-R1, S-S1 e TT1 sono stati collegati prima della consegna Uscita inverter Uscita inverter Resistenza di frenatura ·Reattanza c. c. ( 1- 2) -----·Circuito di frenatura ( 3- ) Resistenza di frenatura ·Reattanza c. c. ( 1- 2) -----·Circuito di frenatura ( 3- ) ------Alimentazione ventola di raffreddamento ----Ingresso alimentazione batteria Terminale di messa a terra (max. 10 ) s/l PO NO 2 Ingresso alimentazione batteria Terminale di messa a terra (max. 55 °C Dissipatore Inverter a telaio aperto Coperchio superiore 50 mm o più 120 mm o più Aria Dissipatore Coperchio inferiore Temperatura presa d'aria inverter ­10 . . . 45 °C 45 °C Temperatura periferica 40 °C 30 mm o più 50 mm o più 30 mm o più 120 mm o più Aria Coperchio inferiore Vite di montaggio del coperchio Spazi laterali Spazi sopra e sotto Dissipazione termica inverter Classe 200 V Modello CIMR-L7Z Capacità dell'inverter kVA A Corrente nominale Dissipazione Dissipatore Interna Totale W W W 23P7 5, 7 15 112 74 186 25P5 8, 8 23 164 84 248 27P5 12 31 219 113 332 2011 17 45 374 170 544 2015 22 58 429 183 612 2018 27 71 501 211 712 2022 32 85 586 274 860 2030 44 115 865 352 1217 2037 55 145 1015 411 1426 2045 69 180 1266 505 1771 2055 82 215 1588 619 2207 Tipo di raffreddamento Raffreddato a ventola Varispeed L7 243 Classe 400 V Modello CIMR-L7Z Capacità dell'inverter kVA A Corrente nominale Dissipazione Dissipatore Interna Totale W W W 44P0 5, 8 7, 6 91 70 161 45P5 9, 5 12, 5 127 82 209 47P5 13 17 193 114 307 4011 18 24 252 158 410 4015 24 31 326 172 498 4018 30 39 426 208 634 4022 34 45 466 259 725 4030 46 60 678 317 995 4037 57 75 784 360 1144 4045 69 91 901 415 1316 4055 85 112 1203 495 1698 Tipo di raffreddamento Raffreddato a ventola Accessori Accessorio di montaggio esterno dissipatore Gli inverter Varispeed L7 classe 200/400 V da 18, 5 kW o inferiore necessitano di questo accessorio per il montaggio esterno del dissipatore. Questo accessorio allarga le dimensioni esterne dell'inverter in larghezza e altezza (l'accessorio non è necessario per gli inverter da 22 kW o superiori). Pannello di montaggio Parete Modello CIMR-L7Z_ 23P7 25P5 27P5 2011 2015 2018 40P4 45P5 47P5 4011 4015 4018 Codice d'ordine accessorio EZZ08676A EZZ08676B EZZ08676C EZZ08676A EZZ08676B EZZ08676C W 155 210 250 155 210 250 H 302 330 392 302 330 392 Dimensioni in mm W1 H1 D1 D2 126 180 216 126 180 216 290 122, 6 57, 4 316 136, 1 63, 4 372 133, 6 76, 4 290 122, 6 57, 4 316 136, 1 63, 4 372 133, 6 76, 4 D3 60 70 85 60 70 85 W1 W H1 H D1 D2 D3 o più Dima di foratura per il montaggio esterno del dissipatore Modello DiseCIMR-L7Z_ gno 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 Dimensioni in mm (W2 (W3 H1 (H2) (H3) ) ) 6 8, 5 290 9, 5 6, 5 316 8, 5 250 392 216 250 400 195 24, 5 275 450 220 2 375 600 250 450 725 325 155 302 126 1 210 330 180 8, 5 250 392 216 275 450 220 2 325 550 260 24, 5 8 535 8, 5 372 9, 5 3 435 8 7, 5 309 519 10 233 353 269 419 M6 6 54, 5 8, 5 372 9, 5 3 8 385 435 575 8 15 10 7, 5 12, 5 6 7 233 353 M6 244 369 269 419 359 545 434 673 138 271 M5 197 298 M10 9 6 7 Foro 4-d a a (H3) W H W1 A B d a b a (H3) (H2) Foro 4-d Due fori Ø 5 155 302 126 1 210 330 180 138 271 M5 197 298 (H2) B B H1 H (W3) A (W3) H1 H (H2) (W3) (W2) A (W3) (W2) 700 13, 5 8, 5 290 9, 5 6, 5 316 9 (W2) (W2) (H2) W1 W (H3) a b a W1 W Figura 1 Figura 2 Intallazionezioni 244 (H3) a a Inverter Opzioni Configurazione del sistema Accessori speciali 7 Filtro di linea R S T 1 8 Varispeed CIMR-L7 Alimentazione Schede di monitor Schede encoder Schede di comunicazione JP3 T1 U6 C3 C33 U7 + + U9 U10 U8 C28 Y1 C1 R U10 JP1 R11 C26 R6 R5 C21 R3 R36 R35 R1 R2 R28 R113 R70 + R7 TR2 U1 11 R11 R110 R107 R120 R8 R55 R52 C2 R75 R114 PE C24 U11 R21 R5 R25 R15 R15 R15 C17 R14 C5 + 2 2 3 + C39 R99 R78 R54 R56 R57 R40 R39 TR1 R6 D6 C22 C16 R131 U14 R20 R30 C35 R95 U12 U15 C11 R102 C12 JP5 C13 JP6 R94 R97 C20 R96 R95 RT4 U13 4 R10 R10 R105 U17 N. codice SI-N 7360 C10 0-C0 210 Schede opzionali di riferimento Scheda opzionale PLC 5 6 A Filtri di linea Modello "foot print" Modello standard 200 V Modello di inverter Varispeed L7 CIMR-L7Z23P7 CIMR-L7Z25P5 CIMR-L7Z27P5 CIMR-L7Z2011 CIMR-L7Z2015 CIMR-L7Z2018 CIMR-L7Z2022 CIMR-L7Z2030 CIMR-L7Z2037 CIMR-L7Z2045 CIMR-L7Z2055 Filtri di linea Tipo 3G3RV-PFI2035-E Classe EN55011 B, 25 m A100 m Corrente (A) 35 Peso (kg) 1, 4 Dimensioni WxDxH 143x46x330 Installazione W1 x H1 x M vite 115x313xM5 Footoprint 3G3RV-PFI2060-E B, 25 m A100 m 60 3 213x60x355 175x336xM6 3G3RV-PFI2100-E B, 25 m A100 m 100 4, 9 238x80x408 205x390xM6 Standard 3G3RV-PFI2130-E A, 100 m 130 4, 3 90x180x310 65x295xM6 3G3RV-PFI2160-E 3G3RV-PFI2200-E 3G3RV-PFI2250-E A, 100 m A, 100 m A, 100 m 160 200 250 6, 0 11, 0 14, 0 120x170x380 130x240x518 130x240x518 102x365xM6 90x498xM8 90x498xM8 Varispeed L7 245 Inverter Accessori di frenatura 400 V Modello di inverter Varispeed L7 CIMR-L7Z44P0 CIMR-L7Z45P5 CIMR-L7Z47P5 CIMR-L7Z4011 CIMR-L7Z4015 CIMR-L7Z4018 CIMR-L7Z4022 CIMR-L7Z4030 CIMR-L7Z4037 CIMR-L7Z4045 CIMR-L7Z4055 Filtri di linea Tipo 3G3RV-PFI3018-E 3G3RV-PFI3035-E 3G3RV-PFI3060-E 3G3RV-PFI3070-E 3G3RV-PFI3100-E 3G3RV-PFI3130-E Classe EN55011 B, 25 m A100 m B, 25 m A100 m B, 25 m A100 m A, 100 m A, 100 m A, 100 m Corrente (A) 18 35 60 70 100 130 Peso (kg) 1, 3 2, 1 4, 0 3, 4 4, 0 4, 7 Dimensioni WxDxH 143x46x330 213x51x355 238x60x408 80x220x329 90x180x310 90x180x310 Installazione W1 x H1 x M vite 115x313xM5 175x336xM6 205x390x6 55x314xM6 65x296xM6 65x295xM6 Schede opzionali Tipo Modello AO-08 / 3G3IV-PAO08 Descrizione Funzione Segnali analogici di monitor uscita dell'inverter (frequenza di uscita, corrente di uscita, ecc. ). · Risoluzione: 8 bit (1/256) · Tensione di uscita: 0. . 10V. Canali di uscita: 2 Schede di monitor AO-12 / 3G3IV-PAO12 Schede analogiche di monitor Segnali analogici di monitor uscita dell'inverter (frequenza di uscita, corrente di uscita, ecc. ). · Risoluzione: 11 bit (1/2048) + codice · Tensione di uscita: 0. . 10V. Canali di uscita: 2 Segnali digitali isolati di monitor dell'inverter durante la marcia (allarme, rilevamento di velocità zero, ecc. ). Uscite: 6 fotoaccoppiate (48 V, 50 mA o inferiore) 2 relè (250 Vc. a, 1 A o inferiore; 30 Vc. c. , 1 A o inferiore) · 2 uscite a relè multifunzione aggiuntive · Ingresso encoder fasi A/B · Risposta in frequenza: 30 kHz max. (alimentazione scheda PG: +12 V, corrente max. 200 mA) · Uscita di monitor degli impulsi: open collector, +24V, corrente max. 30 mA Standard B Footprint DO-08 / 3G3IV-PDO08 DO-02C / 3G3IV-PDO02C PG-B2 / 3G3FV-PPGB2 Scheda digitale di m onitor Scheda di uscita 2 relè C Schede encoder PG-X2 / 3G3FV-PPGX2 Schede encoder PG di controllo della velocità (per modalità V/f con PG o vettoriale di flusso) · PG-F2 · Ingresso encoder fasi differenziali A/B/Z · Risposta in frequenza: 300 kHz max. [. . . ] MCCB Motore Varispeed L7 Esempio applicativo Potenza nominale alimentatore (kVA) Reattanza c. a. necessaria per controllo armoniche di alimentazione Reattanza c. a. non necessaria Capacità inverter (kVA) Potenza di uscita motore massima applicabile (kW) 3, 7 5, 5 7, 5 11 15 18, 5 22 30 37 45 55 Classe 200 V Valore di corrente (A) Induttanza (mH) 20 30 40 60 80 90 120 160 200 240 280 0, 53 0, 35 0, 265 0, 18 0, 13 0, 12 0, 09 0, 07 0, 05 0, 044 0, 038 Potenza di uscita motore massima applicabile (kW) 4, 0 5, 5 7, 5 11 15 18, 5 22 30 37 45 55 Classe 400 V Valore di corrente (A) Induttanza (mH) 10 15 20 30 40 50 60 80 90 120 150 2, 2 1, 42 1, 06 0, 7 0, 53 0, 42 0, 36 0, 26 0, 24 0, 18 0, 15 Reattanza c. c. Esempio di collegamento Reattanza c. c. MCCB Esempio applicativo Motore Potenza nominale alimentazione (kVA) Con reattanza per coordinamento alimentazione Senza reattanza Varispeed L7 Rimuovere il collegamento G1 e G2 e cablare come illustrato in figura. Capacità inverter (kVA) Classe 200 V Potenza di uscita motore massima applicabile (kW) 3, 7 5, 5 7, 5 11 15 18, 5 22 . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CIMR-L7Z

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CIMR-L7Z will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag