User manual OMRON CIMR-V7AZ DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON CIMR-V7AZ. We hope that this OMRON CIMR-V7AZ user guide will be useful to you.

Lastmanuals help download the user guide OMRON CIMR-V7AZ.


Mode d'emploi OMRON CIMR-V7AZ
Download
Manual abstract: user guide OMRON CIMR-V7AZDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] output frequency Rated input voltage and frequency Allowable voltage fluctuation Allowable frequency fluctuation 1. 0. 37 0. 9 1. 2 40P2 40P4 40P405 0. 55 1. 4 1. 8 40P7 40P705 1. 1 2. 6 3. 4 41P5 41P505 1. 5 3. 7 4. 8 ~ 42P2 42P205 2. 2 4. 2 5. 5 43P0 43P005 3. 0 5. 5 7. 2 44P0 44P005 4. 0 7. 0 9. 2 45P5 5. 5 11. 0 14. 8 47P5 7. 5 14. 0 18. 0 Proportional to input voltage: 0. . 400 V 400 Hz 3-phase 380. . 460 VAC, 50/60 Hz -15%. . +10% +5% Power supply Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current 330 Frequency inverters Commom specifications Model number CIMR-V7AZ-@ CIMR-V7TZ-@ Control methods Output frequency range Frequency tolerance Control functions Resolution of frequency set value Resolution of output frequency Overload capability Frequency set value Specifications Sine wave PWM (V/f control, sensorless vector control) 0. 1. . 400 Hz Digital set value: ±0. 01% (-10. . +50 ºC) Analogue set value: ±0. 5% (25 ±10 ºC) Digital set value: 0. 01 Hz (<100 Hz), 0. 1 Hz (>100 Hz) Analogue set value: 1/1000 of maximum frequency 0. 01 Hz 150%/60 s 0. . 10 V (20 k), 4. . 20 mA (250 ), 0. . 20 mA (250 ) Pulse train input, frequency setting value (selectable) Up to 200 W 150% or more 550 W to 1. 1 kW 100% or more 1. 5 kW 50% or more >1. 5 kW 20% or more Continuous braking torque approx. 20% without, 150% with external braking resistor 7 freely programmable inputs 1 relay output, 2 freely programmable open collector outputs 1 programmable analogue output (0. . 10 V)/pulse output 2 analogue inputs, 0. . 10 V, 4. . 20 mA, 0. . 20 mA 0. 01. . 6000 s Optionally frequency, current or set value Error and status LED Electronic thermal overload relay Motor coasts to a stop at approx. [. . . ] 4. V7 IP65 types have digital operator without frequency adjuster. The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit. While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the parameter setting indicator is lit. For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF before using this function. 332 Frequency inverters Dimensions IP 20 type 0. 1 to 4 Kw 2 M4 4 M4 H1 H H2 W1 W 8. 5 (0. 34) D1 D H2 H1 H W1 W 8. 5 (0. 34) D1 D Figure 1 Voltage class Max. applicable motor output kW 0. 12 0. 25 0. 55 Three-phase 200 V 1. 1 1. 5 2. 2 4. 0 0. 12 0. 25 0. 55 Single-phase 200 V 1. 1 1. 5 2. 2 4. 0 0. 37 0. 55 1. 1 Three-phase 400 V 1. 5 2. 2 3. 0 4. 0 Inverter model CIMR V7AZ 20P1 20P2 20P4 20P7 21P5 22P2 24P0 B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B4P0 40P2 40P4 40P7 41P5 42P2 43P0 44P0 140 2 108 128 2 108 140 170 128 1 68 2 108 140 1 68 128 Figure Dimensions in mm W H D 76 108 128 131 140 143 76 76 131 140 156 163 180 92 110 140 156 143 128 96 96 96 128 158 56 96 128 56 W1 Figure 2 Weight kg 0. 6 0. 6 0. 9 1. 1 1. 4 1. 5 2. 1 0. 6 0. 7 1. 0 1. 5 1. 5 2. 2 2. 9 1. 0 1. 1 1. 5 118 5 64 1. 5 1. 5 71 2. 1 2. 1 Fan cooled Self cooled Fan cooled Self cooled Fan cooled Self cooled Cooling method H1 H2 D1 10 5 118 5 42 62 64 71 118 5 10 42 64 118 5 71 16 34 IP20 / NEMA1 type 5. 5/7. 5 Kw Figure 3 Voltage class Three-phase 200 V Three-phase 400 V Max. applicable motor output kW 5. 5 7. 5 5. 5 7. 5 Inverter model CIMR - V7AZ 25P5 27P5 45P5 47P5 3 180 260 170 164 244 8 65 Figure Dimensions in mm (inches) W 180 H 260 D 170 W1 164 H1 244 H2 8 D1 65 Weight kg 4. 6 4. 8 4. 8 4. 8 Fan cooled Cooling method Varispeed V7 333 IIP65 type 0. 55 to 4 Kw W2 H1 D D1 H W W1 6. 4 H2 H1 3x PG25 Figure 4 Voltage class Max. applicable motor output kW 0. 55 1. 1 1. 5 2. 2 0. 55 1. 1 Inverter model CIMR V7TZ B0P405 B0P705 B1P505 B2P205 40P405 40P705 41P505 42P205 43P005 44P005 Dimensions in mm Figure W H D W1 W2 H1 H2 H3 D1 Weight kg 3. 4 280 240 142 260 228 165 38 275 44 4. 3 3. 7 4. 2 4 280 240 142 260 228 165 38 275 44 4. 2 4. 3 3. 7 3. 7 4. 1 4. 1 Fan cooled Self cooled Fan cooled Cooling method Self cooled Single-phase 200 V Three-phase 400 V 1. 5 2. 2 3. 0 4. 0 334 Frequency inverters IP65 type 0. 55 to 4Kw (with option frame accessory attached) W2 H1 D2 D D1 H W W1 6. 4 H2 H1 2x PG12 3x PG25 Figure 5 Voltage class Max. weight kg 3. 0 4. 5 4. 5 5. 0 7. 5 8. 5 3. 0) 4. 5 4. 5 5. 0 7. 5 8. 5 200 V class 22P2 40P7 25P5 27P5 40P7 41P5 42P2 400 V class 43P0 43P7 45P5 47P5 Varispeed V7 339 Installation Standard connections Thermal overload relay (option) X DC reactor (option) U Short bar +2 R/L1 +1 Braking resistor (option) MCCB R S T ­ B1 B2 Line filter 1* S/L2 T/L3 NPN 24 V U/T1 V/T2 W/T3 Grounding IM Forward run/stop Reverse run/stop External fault (no contact) Multifunction input Fault reset Multi-step speed reference 1 Multi-step speed reference 2 JOG command S1 S2 S3 S4 S5 S6 S7 SC PHC PHC PHC PHC PHC PHC PHC PNP MA MB MC Fault Multi-function output 250 VAC 1 A or less 30 VDC 1 A or less P1 Running Pulse train input Frequency reference 2k P Frequency setter P Shield connection terminal Speed reference RP pulse train (33 kHz max. ) Frequency setting FS power supply (+12 V 20 mA) Speed frequency FR reference 0 to +10 V (20 k) OR FC 4 to 20 mA (250 ) 0V Digital operator frequency setting potentiometer min max CN2 P2 Speed agree PC Multi-function photocoupler output +48 VDC 50 mA or less Housing (type : ZHR-3) VIN IIN GND 0 to 10 V P 4 to 20 mA 0V Multi-function analog input 2* R+ AM R­ MEMOBUS communication RS-485/422 max 19. 2kBPS Terminal resistance (1/2 W. 120 ) AC S+ S­ Frequency meter adjusting potentiometer Analog monitor output P FM 0 TO +10 VDC (2 mA) Pulse monitor output Output (12 VDC frequency 20 mA max. 30 - 70% duty) 1* V7 IP65 types are built-in filter. 2* A housing is required when using the CN2 terminal on the back side of the digital operator. 3G3MV-PCN-CN2) is available for housing on request : shielded wire P : twisted pair shielded wire Shows the following two kinds of connections (factory setting) : · Input signals (S1 to S7) are non-voltage contacts · Sequence connection by NPN transistor (0V common) A +24 V power supply is required for sequence connection by PNP transistor (+24 V common) . 340 Frequency inverters Main circuit Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 B1, B2 +2, +1 +1, ­ Name AC power supply input Inverter output Braking resistor connection DC reactor connection DC power supply input Grounding Function (signal level) Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0. 75 kW for other usage, such as a junction terminal. ) For inverter output For braking resistor connection Remove the short bar between +2 and +1 when connecting DC reactor (option) For power supply input (+1: positive electrode; ­ : negative electrode)* For grounding (grounding should conform to the local grounding code. ) Control Circuit Type No. S1 S2 Digital input signals S3 S4 S5 S6 S7 SC RP Analog input signals FS FR FC 1 (CN2) 2 (CN2) 3 (CN2 Digital output signals MA NC MC P1 P2 PC Analog output signals AM AC R+ RS-485/422 R­ S+ S­ Signal name Multi-function input selection 1 Multi-function input selection 2 Multi-function input selection 3 Multi-function input selection 4 Multi-function input selection 5 Multi-function input selection 6 Multi-function input selection 7 Multi-function input selection Common Speed reference pulse train input Power supply terminal for frequency setting Speed frequency reference Frequency reference common Multi-function analog voltage input Multi-function analog current input Multi-function analog input common NO contact output Contact output Contact output common Photocoupler output 1 Photocoupler output 2 Photocoupler output common Analog monitor output Analog monitor common Communication input (+) Communication input (­) Communication output (+) Communication output (­) For MEMOBUS communication operation by RS-485 or RS-422 communication is available. RS-485/422 MEMOBUS protocol 19. 2 kBPS max. Factory setting: "running" Factory setting: "at frequency" 0V Factory setting: "output frequency" 0 to +10 V output (pulse monitor output available by setting constants. Duty: 30 to 70%) 0V 0 to 10 V 2 mA or less Resolution: 8 bits Photocoupler output: +48 VDC, 50 mA or less Factory setting: "fault" Contact capacity 250 VAC, 1 A or less 30 VDC, 1 A or less Function Factory setting: runs when CLOSED, stops when OPEN. Factory setting: runs when CLOSED, stops when OPEN. Factory setting: "fault reset" Factory setting: "external fault (NO contact)" Factory setting: "multi-step speed reference 1" Factory setting: "multi-step speed reference 2" Factory setting: "JOG command" Common for control signal 33 kHz max. +12V (allowable current: 20 mA max. ) 0 to +10 VDC (20 k) or 4 to 20 mA (250 ), 0 to 20 mA (250 ) (resolution 1/1000) 0V Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 k) Current input (between terminals 2 and 3): 4 to 20 mA (input impedance: 250 ) 24VDC, 8mA photocoupler insulation Signal level Varispeed V7 341 W= 30 mm min. [. . . ] applicable motor output kW Inverter model CIMR-V7AZ Inverter-mounted type (3 %ED, 10 sec max) Braking resistor unit Separately-installed type (10 %ED, 10 sec. max. ) Threephase 0. 12 0. 25 0. 55 200 V (single-/ three-phase) 1. 1 1. 5 2. 2 4. 0 5. 5 7. 5 0. 37 0. 55 1. 1 400 V (threephase) 1. 5 2. 2 3. 0 4. 0 5. 5 7. 5 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 27P5 40P2 40P4 40P7 41P5 42P2 43P0 44P0 45P5 47P5 Singlephase B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B4P0 ­ ­ ­ ­ ­ ­ ­ ­ ­ ­ ­ Model ERF150WJ_ 401 401 201 201 101 700 620 ­ ­ 751 751 751 401 301 401 ­ ­ Resistance 400 400 200 200 100 70 62 ­ ­ 750 750 750 400 300 400 ­ ­ No. of used 1 1 1 1 1 1 1 ­ ­ 1 1 1 1 1 2 ­ ­ Braking torque % 220 220 220 125 125 120 100 ­ ­ 230 230 130 125 115 105 ­ ­ Model LKEB# ­ ­ 20P7 20P7 21P5 22P2 23P7 25P5 27P5 ­ 40P7 40P7 41P5 42P2 43P7 45P5 47P5 Resistor spec. (per one unit) W ­ ­ 70 200 70 200 260 100 260 390 520 780 ­ 70 750 70 750 260 400 260 250 390 150 520 100 780 75 70 40 30 20 No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CIMR-V7AZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CIMR-V7AZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag