User manual OMRON CX-INTEGRATOR V2 12-2009

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON CX-INTEGRATOR V2. We hope that this OMRON CX-INTEGRATOR V2 user guide will be useful to you.

Lastmanuals help download the user guide OMRON CX-INTEGRATOR V2.


Mode d'emploi OMRON CX-INTEGRATOR V2
Download
Manual abstract: user guide OMRON CX-INTEGRATOR V212-2009

Detailed instructions for use are in the User's Guide.

[. . . ] W464-E1-06 SYSMAC CXONE-AL_C-V4/ CXONE-AL_D-V4 CS/CJ/CP/NSJ Series CX-Integrator Ver. 2. @ Operation Manual Revised December 2009 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. [. . . ] Click the Table View Tab and edit the local network table and relay network table. Transferring Edited Routing Tables 1. Specify each node (in the same network) and select Options ­ Transfer to PLC. The routing tables will be transferred to each PLC through the network. Saving the FINS Network Routing Table File 1. Select File ­ Save Network Routing Table File in the PLC Routing Table Window. Input the filename, specify the directory where the file will be saved, and click the Save Button. Note When transferring the routing tables to a PLC, all CPU Bus Units in that node will be reset except for SYSMAC BUS/2 Masters. Verify that there will be no adverse effects on the system's equipment before transferring the routing tables. 3-35 3-3 Maintenance after Network Configuration 3-3-2 Editing the FINS Local Network Tables 3-36 Communications Section 4 Data Links for Controller Link and SYSMAC LINK This section describes how to set data links for Controller Link and SYSMAC LINK networks. 4-1 4-1-1 Overview What Are Data Links? 4-1 4-1-1 Overview What Are Data Links? Data links automatically exchange data in preset areas between nodes (PLCs and/or computers) on a network. Settings can be made either manually or automatically. CX-Integrator operations can be used for all operations from setting up the PLC network to controlling data exchange. Manual Settings Manual settings enable more flexible allocations, including the send size for each node, the sequence of nodes for sending and receiving, and the setting of nodes for sending only or receiving only. Use manual settings to create flexible data links to meet the requirements of the individual system (e. g. , efficient utilization of memory, restrictions on allocated addresses, etc. ). Data link tables (i. e. , tables that define data link area allocations) are generated by CX-Integrator or network support software (such as Controller Link Support Software), and sent to all nodes for use. Automatic Settings Automatic settings can be used for simple data exchanges involving fixed allocations, when all nodes are set for the same send size and the same data is to be shared among all nodes in order of node address. Using a Programming Device (such as the CX-Programmer or a Programming Console), set the data exchange method in the DM parameter area of the startup node. 4-2 4-1 4-1-2 Overview Overview of Procedure by Data Link Setting Method 4-1-2 Overview of Procedure by Data Link Setting Method Step 1: Selecting the Data Link Setting Method Either of the following methods can be used. 1) Select either user-set data links or automatically set data links after selecting Online - Automatic Data Link Setup from the Data Link Component. 2) Directly set the software switches in the allocated DM Area words. Note: The settings in the DM Area can also be made from the Special I/O Unit settings in the I/O Table Window for CX-Programmer Ver. 6. 0 or higher. Right-click the Controller Link Unit or SYSMAC LINK Unit in the I/O Table Window, select Unit Setup from the popup menu, and then select Data Link mode from the Edit Parameters Dialog Box. Controller Link Unit: Select Manual setting, Automatic setting (equality layout), or Automatic setting (1:N allocation) SYSMAC LINK Unit: Manual setting, Automatic setting (CIO Area only), Automatic setting (DM Area only), or Automatic setting (CIO + DM Areas). Place the CX-Programmer online and transfer the parameters to the PLCs. (The Compare Button can be clicked to set the parameters which verifying against the setting data in the actual PLCs. Step 2: Data Link Allocation Area Settings Manual: Automatic: Select Table - Wizard from the Data Link Component online or select File - New, create the data link tables, and then go online and transfer the tables to all nodes in the network. 1) Select Online - Automatic Data Link Setup from the Data Link Component and set the parameters for automatically setting data links. 2) Directly set the parameter area for automatically allocating data links in the allocated DM Area words. Note: The Special I/O Unit settings in the I/O Table Window can also be used to set parameters for automatically allocating data links and then these parameters can be transferred to the startup node. Step 3: Starting the Data Links Automatic or manual: Use one of the following methods. 1) Select Online - Data Link Operation/Status from the Data Link Component, select the RUN Option under Operation and then click the Set Button. 2) Turn ON the Data Link Start Bit in the DM Area words allocated to the start node and then cycle the power to the PLC. [. . . ] The device will be deleted from the Hardware List together with the EDS file. A-2-4 Saving EDS Files Tools - EDS File - Save To save the EDS file, use the following procedure. Select the device from the Hardware List. The following window will be displayed to specify the name of the folder where the EDS file will be saved and the name of the EDS file. 3. Input the folder and file names and click the Save Button The EDS file will be saved. A-7 A-2 EDS File Management A-2-5 Searching EDS Files A-2-5 Searching EDS Files Tools - EDS File - Search To search the device (EDS file) displayed in the Hardware List, use the following procedure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CX-INTEGRATOR V2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CX-INTEGRATOR V2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag