[. . . ] Cable length Model XS2F-A421-C90-A XS2F-A421-D90-A XS2F-A421-G90-A XS2F-A421-J90-A XS2F-D421-C80-A XS2F-D421-D80-A XS2F-D421-G80-A XS2F-D421-J80-A 2 Miniature Limit Switch D4CC Special Mounting Plate It is possible to replace an WL Limit Switch with a D4CC Limit Switch mounted on this plate without changing the position of the dog or cam. The following is the conversion table: WL Top plunger: WLD Top roller plunger: WLD2 Roller lever: WLG2 D4C Plunger: D4CC-@001 Roller plunger: D4CC-@002 Roller lever: D4CC-@024 Plate model D4C-P001 D4C-P002 D4C-P020 Remarks There is no difference in mounting pitch between the Mounting Plate and the WL. The mounting depth of the D4CC with the Mounting Plate attached is, however, shorter than that of the panel-mounted WL. Plate Example Dog Dog Mounting plate Specifications Approved Standards Agency UL CSA Standard UL508 CSA C22. 2 No. E76675 LR45746 Approved Standard Ratings UL-CSA D4CC-1, D4CC-2 D150 Rated voltage 120 VAC Carry current 1. 0 A Current Make 3. 6 A Break 0. 6 A Volt-amperes Make 432 VA Break 72 VA Ratings Rated voltage NC 125 VAC 30 VDC Note: 1. [. . . ] "Lights when not in operation" means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes into contact with the NO side, the indicator turns OFF. Plugs AC Type Pin No. Black DC Type Pin No. Plug Cable 1. Black Miniature Limit Switch D4CC 5 Nomenclature Roller s Center lever Spacer (prevents the Switch from biting cut chips. ) O ring (NBR) O ring (NBR) Nitrile rubber diaphragm Protective nitrile rubber cap (NBR) Open space (to reduce a change in internal pneumatic pressure and to prevent the respiratory movement of the Switch. ) LED indicator Connector receptacle Ground terminal Molded resin Built-in switch 6 Miniature Limit Switch D4CC Dimensions Note: 1. All units are in millimeters unless otherwise indicated. The @ in each model number is replaced with the code expressing the rated load of the model. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. Limit Switches Pin Plunger D4CC-@001 PT 10 dia. stainless steel plunger +0. 2 Two, 5. 1 0 dia. holes 25±0. 1 16 (counter-sunk 10. 2 dia. ; depth: 6) 4. 5 7. 5 8 2 23 Roller Plunger D4CC-@002 Correct setting position 2. 8 OP PT 12 dia. 0 holes (counter-sunk 10. 2 dia. ; depth: 6) 7 7. 5 8 59. 5 max. 2 23 16 Correct setting position 2. 8 OP 62. 2 max. 75 max. 10. 5 (2) 2 34 Indicator M12 x 1 34 1. 4 1. 5 10. 5 (2) 2 1. 4 1. 5 Indicator M12 x 1 Crossroller Plunger D4CC-@003 PT 12 dia. 16 0 holes (counter-sunk 10. 2 dia. ; depth: 6) 7 7. 5 8 2 23 Bevel Plunger D4CC-@010 10 dia. stainless steel plunger Correct setting position 2. 8 OP 40 max. 25±0. 1 16 Correct setting position 2. 8 PT OP Two, 5. 1+0. 2 dia. 0 holes (counter-sunk 10. 2 dia. ; depth: 6) 7 7. 5 8 75 max. 2 23 10. 5 (2) 2 Indicator M12 x 1 34 17. 5 dia. 44±0. 8 1. 4 1. 5 10. 5 (2) Indicator 34 M12 x 1 2 1. 4 1. 5 Roller Lever D4CC-@024 Sealed Pin Plunger D4CC-@031 PT 40 max. stainless steel plunger Rubber seal Two, 5. 1+0. 2 dia. 16 0 holes (counter-sunk 10. 2 dia. ; depth: 6) 4 7. 5 8 57 max. 2 23 38R 31. 5±0. 8 16 OP 110. 7 max. 7 11. 4 7. 5 M5 Allen8 head bolt (length: 12) 2 23 10. 5 (2) Indicator 34 M12 x 1 1. 5 2 1. 4 1. 5 (2) 10. 5 Indicator M12 x 1 34 Two, 5. 1+0. 2 dia. 0 holes (counter-sunk 10. 2 dia. ; depth: 6) 2 1. 4 Miniature Limit Switch D4CC 7 Sealed Roller Plunger D4CC-@032 PT 12 dia. 25±0. 1 16 Sealed Crossroller Plunger 12 dia. [. . . ] Make sure, however, that the plug connector is tightened securely, otherwise the rated degree of protection of the D4CC may not be maintained. Furthermore, the plug connector may be loosened by vibration. Properly Tightened Connector (B) D4CC (A) Miniature Limit Switch D4CC 11 Operation Operation method, shapes of cam and dog, operating frequency, and overtravel have a significant effect on the service life and precision of a Limit Switch. For this reason, the dog angle must be 30° max. , the surface roughness of the dog must be 6. 3S min. To allow the plunger-type actuator to travel properly, adjust the dog and cam to the proper setting positions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D4CC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON D4CC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag