User manual OMRON D4GS-N DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON D4GS-N. We hope that this OMRON D4GS-N user guide will be useful to you.

Lastmanuals help download the user guide OMRON D4GS-N.


Mode d'emploi OMRON D4GS-N
Download
Manual abstract: user guide OMRON D4GS-NDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 14 is authorized by the UL mark. Standards and EC Directives Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN1088 EN60204-1 Approved Standard Ratings TÜV (EN60947-5-1) Item Rated operating current (Ie) Rated operating voltage (Ue) AC-15 0. 75 A 240 V DC-13 0. 27 A 250 V Note: Use a 10-A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. UL/CSA (UL508, CSA C22. 2 No. 14) C300 Rated voltage 120 VAC 240 VAC Carry current 2. 5 A Current (A) Make 15 7. 5 Break 1. 5 0. 75 Make 1, 800 Voltage (VA) Break 180 Q300 Rated voltage 125 VDC 250 VDC Carry current 2. 5 A Current (A) Make 0. 55 0. 27 Break 0. 55 0. 27 Make 69 Voltage (VA) Break 69 D4GS-N G-165 D4GS-N Characteristics Degree of protection (see note 1) Durability (see note 2) Operating speed Contact gap Operating frequency Direct opening force (see note 4) Direct opening travel (see note 4) Insulation resistance Minimum applicable load (see note 5) Contact resistance Dielectric strength Conditional short-circuit current Pollution degree (operating environment) Conventional free air thermal current (Ith) Protection against electric shock Vibration resistance Shock resistance Ambient temperature Ambient humidity Cable Weight Body: IP67 (EN60947-5-1) (Operation Key insertion face: IP00) Mechanical:1, 000, 000 times min. (1-A resistive load at 125 VAC) (see note 3) 0. 1 to 0. 5 m/s 2 x 2 mm min. (at 500 VDC) between terminals of the same polarities, between terminals of different polarities, and between each terminal and non-current carrying metal parts 4 mA at 24 VDC 300 m max. [. . . ] The terminals 11-12 and 31-32 can be used as unlike poles. Only NC contacts 11-12 and 2122 have an approved direct opening mechanism. The terminals 11-12, 21-22 and 33-34 can be used as unlike poles. NC contacts 11-12, 21-22 and 31-32 have an approved direct opening mechanism. The terminals 11-12, 21-22 and 31-32 can be used as unlike poles. Extraction completion position ON D4GS-N3#-# 2NC/1NO Stroke Operation Key insertion completion position Extraction completion position ON D4GS-N4#-# 3NC Stroke Operation Key insertion completion position Extraction completion position D4GS-N G-167 D4GS-N Dimensions Note: 1. All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. Switches D4GS-N#R-# Red Black 2. 15±0. 05R mounting hole: (Operation Key center position) Operating characteristics UL Style 2464 AWG22 Finishing O. D. : 7. 2 mm Model 15 N max. 10 mm min. Key insertion force Key extraction force Movement before being locked Direct opening force Direct opening stroke D4GS-N#T-# Red 8. 4 (Operation Key center position) Black 2. 15±0. 05R mounting hole: UL Style 2464 AWG22 Finishing O. D. : 7. 2 mm G-168 Safety Sensors / Components Operation Keys D4GS-NK1 Two, 4. 3 dia. rubber D4GS-NK2 Red 1. 4 (Operation Key center position) Mounting rubber Two, 4. 3 dia. 12. 6 (Operation Key center position) D4GS-NK4 Black Adjusting screw (Set screw with M4 hexagonal hole) Four, 8R Two, 8 dia. Two, 4. 2 dia. With Operation Key Inserted D4GS-N#R-# + D4GS-NK1 Red Key insertion radius (R 170) D4GS-N#R-# + D4GS-NK2 Red Key insertion radius (R 170) Black 13. 5 to 16 Key insertion position Black 5. 4 to 7. 9 Key insertion position Key insertion face Key insertion radius (R 160) Key insertion face (41±1) (See note. ) 13. 5 to 16 Key insertion position 13. 5 to 16 Key insertion position Key insertion face (27±1) (See note. ) 5. 4 to 7. 9 Key insertion position Key insertion face 5. 4 to 7. 9 Key insertion position Key insertion radius (R 160) (41±1) (See note. ) (27±1) (See note. ) Key insertion radius (R 160) Key insertion radius (R 160) Note: Mount with dimension of 26. 4 for 160 £ R £ 240. Note: Mount with dimension of 27. 7 for 160 £ R £ 240. Note: Mount with dimension of 40. 3 for 160 £ R £ 240. Note: Mount with dimension of 41. 6 for 160 £ R £ 240. D4GS-N G-169 D4GS-N Note: 1. All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. D4GS-N#T-# + D4GS-NK1 D4GS-N#T-# + D4GS-NK2 Red Red Key insertion radius (R 170) Black Black Key insertion radius (R 170) 13. 5 to 16 Key insertion position Key insertion face (12. 3±1) (See note. ) Key insertion radius (R 160) 13. 5 to 16 Key insertion position 13. 5 to 16 Key insertion position (12. 3±1) (See note. ) Key insertion face Key insertion radius (R 160) Key insertion radius (R 160) 5. 4 to 7. 9 Key insertion position Key insertion face (21±1) (See note. ) Key insertion face 5. 4 to 7. 9 Key insertion positio (21±1) (See note. ) Key insertion radius (R 160) Key insertion face 5. 4 to 7. 9 Key insertion position Note: Mount with dimension of 11. 6 for 160 £ R £ 240. Note: Mount with dimension of 13 for 160 £ R £ 240. Note: Mount with dimension of 20. 3 for 160 £ R £ 240. Note: Mount with dimension of 21. 7 for 160 £ R £ 240. D4GS-N#R-# + D4GS-NK4 Red Adjusting screw 21. 5 to 24 Key insertion position Key insertion radius (R 50) D4GS-N#T-# + D4GS-NK4 Key insertion radius (R 50) Red Black Black Adjusting screw 21. 5 to 24 Key insertion position Note 1: When determining the operation key insertion radius, adjust the adjusting screw so that the tip of the operation key is positioned to the center of the key insertion hole of the Switch. Note 2: The operation key cannot be inserted or adjusted in a direction different from the one shown above. Use the D4GS-NK1 or D4GS-NK2 if necessary. Note 1: When determining the operation key insertion radius, adjust the adjusting screw so that the tip of the operation key is positioned to the center of the key insertion hole of the Switch. Note 2: The operation key cannot be inserted or adjusted in a direction different from the one shown above. Use the D4GS-NK1 or D4GS-NK2 if necessary. Note: 1. All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. G-170 Safety Sensors / Components Precautions Do not insert the Operation Key to the switch with the door open. Machine may start operating and injury may be caused. Correct Use Operating Environment Do not use the D4GS-N in the following locations: · · · · Locations subject to severe temperature changes Locations subject to high temperatures or condensation Locations subject to severe vibration Locations subject to metal chips, oils, and chemicals inside a protective door NOTICE Do not use the D4GS-N# Switch or D4GS-NK# Operation Key (rubber color: red) in combination with the D4GS-# Switch or D4GS-K# Operation Key (rubber color: black). [. . . ] If the rubber becomes deformed or cracked, replace it as soon as possible. Force imposed Color of insulation Blue/white Brown/white Orange/white 4 5 6 No. Color of insulation Orange Brown Blue 1 2 3 Note: "Blue/white, brown/white, or orange/white" means that the cover is blue, brown, or orange with a white line. Terminal Numbers Identify terminal numbers based on the color of the insulation on the wire. The safety and auxiliary contacts of D4GS-N models of three-terminal contact construction and those of two-terminal contact construction are described below. The auxiliary contacts (orange) can be used as safety contacts. The safety contacts are direct opening contacts approved by EN and each of them is indicated with the mark . Drop <3NC> Securing the Door When the door is closed (with the Operation Key inserted), the door (or the Operation Key) may be pulled outside the set zone due to the door's weight or the door cushion rubber. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D4GS-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON D4GS-N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag