User manual OMRON DRT2-D16S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON DRT2-D16S. We hope that this OMRON DRT2-D16S user guide will be useful to you.

Lastmanuals help download the user guide OMRON DRT2-D16S.


Mode d'emploi OMRON DRT2-D16S
Download
Manual abstract: user guide OMRON DRT2-D16S

Detailed instructions for use are in the User's Guide.

[. . . ] General Specifications Item Communications power supply voltage I/O power supply voltage Communications power supply current consumption Dielectric strength Noise immunity Vibration resistance Shock resistance Mounting methods Tightening torque Ambient operating temperature Ambient operating humidity Storage temperature Weight 90 g max DRT2-ID16S (-1) DRT2-MD16S (-1) 11 to 25 VDC (Supplied from communications connector. ) Supplied from communications connector; output supplied from external source. 135 mA max. Input Specifications 16 Inputs Item Model number Internal I/O common processing Number of I/O points ON voltage OFF voltage OFF current Input current ON delay time OFF delay time Number of circuits DRT2-ID16S NPN 16 inputs 15 VDC min. [. . . ] or M4 holes Residual voltage and current Leakage current ON delay time OFF delay time Number of circuits Load short-circuit detection current 2 V max. at 0. 3 ADC, between each output terminal and V output terminal and G 0. 1 mA max. per common 88±0. 2 Mounting hole dimensions Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product. The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. Note: Do not use this document to operate the Unit. OMRON Corporation FA Systems Division H. Q. 66 Matsumoto Mishima-city, Shizuoka 411-8511 Japan Tel: (81)55-977-9181 Fax: (81)55-977-9045 Regional Headquarters OMRON EUROPE B. V. [. . . ] This allows stable and continuous operation of the system. Internal Circuit Diagrams Appropriate wire size 28 to 24 AWG (0. 08 to 0. 2 mm2); Outer diameter including insulation: 0. 9 to 1. 0 mm 24 to 22 AWG (0. 2 to 0. 3 mm2); Outer diameter including insulation: 1. 0 to 1. 15 mm 22 to 20 AWG (0. 3 to 0. 5 mm2); Outer diameter including insulation: 1. 15 to 1. 35 mm Maintain stable communications. Input and output device short-circuit deteced and notification provided. Detect and protect against power supply short-circuits. Simple Crimping OMRON Connectors Model number XN2A-1430 Specifications Spring clamp Appropriate wire size 28 to 20 AWG (0. 08 to 0. 5 mm2); Outer diameter including insulation: 1. 5 mm max. Input shortcircuit Output shortcircuit Tyco Electronics AMP Connectors Model number 1-1473562-4 1473562-4 2-1473562-4 Specifications/Housing color Red Yellow Blue DRT2-ID16S (NPN) V+ CAN H DRAIN CAN L V­ Physical layer V NC G1 IN0 DRT2-ID16S-1 (PNP) Short-circuit protection element Short-circuit detection circuit Internal circuits Sumitomo 3M Connectors Model number 37104-3101-000FL Specifications/Housing color Red Yellow Orange Green Blue Gray Appropriate wire size 26 to 24 AWG (0. 14 to 0. 2 mm2); Outer diameter including insulation: 0. 8 to 1. 0 mm 26 to 24 AWG (0. 14 to 0. 2 mm2); Outer diameter including insulation: 1. 0 to 1. 2 mm 26 to 24 AWG (0. 14 to 0. 2 mm2); Outer diameter including insulation: 1. 2 to 1. 6 mm 22 to 20 AWG (0. 3 to 0. 5 mm2); Outer diameter including insulation: 1. 0 to 1. 2 mm 22 to 20 AWG (0. 3 to 0. 5 mm2); Outer diameter including insulation: 1. 2 to 1. 6 mm 22 to 20 AWG (0. 3 to 0. 5 mm2); Outer diameter including insulation: 1. 6 to 2. 0 mm Internal circuits V+ CAN H DRAIN CAN L V­ V1 NC G IN0 Physical layer V1 NC G IN1 All I/O points have a common terminal, so an intermediate terminal is not needed! 37104-3122-000FL 37104-3163-000FL 37104-2124-000FL 37104-2165-000FL 37104-2206-000FL DC static converter (non-isolated) V NC G1 IN1 DC static converter (non-isolated) Short-circuit detection circuit Short-circuit protection element Compatible Sensors (With Industry-standard Sensor Connectors (Male)) Photoelectric Sensors with Built-in Amplifier E3Z-ECON E3T-ECON Photomicrosensors EE-SX77 -ECON EE-SX87 -ECON Extension Cables E39-ECON M (Female E-CON connector on one end. ) E39-ECONW M (Female E-CON connector on one end, male E-CON connector on the other end. ) Pin number 1 2 3 4 1 2 3 4 Signal name (color) 12 to 24 VDC (brown) Open 0 V (blue) Control output (black) Sensor model E3Z series E3T series EE-SX series Cable lengths 0. 3 m, 0. 5 m, or 2 m 0. 3 m or 2 m DRT2-MD16S (NPN) Short-circuit protection element Short-circuit detection circuit DRT2-MD16S-1 (PNP) Short-circuit protection element Short-circuit detection circuit Pin number 1 2 3 4 1 2 3 4 Extension Cable color Brown White Blue Black Sensor model E39-ECON M E39-ECONW M Cable lengths 2 m or 5 m 0. 5 to 2 m (in 0. 1-m increments) Example model numbers E3Z-T61-ECON 0. 3m E3T-FT11-ECON 2m E39-ECON2M E39-ECONW0. 5M V+ CAN H DRAIN CAN L V­ Physical layer V NC G1 IN0 V+ CAN H DRAIN CAN L V­ Physical layer V1 NC G IN0 Internal circuits V0 V0 G0 G0 NC NC G2 OUT0 Voltage step-down Internal circuits Voltage step-down V2 NC NC OUT0 DC static converter (non-isolated) Detection circuit Smart Functions The Terminals provide smart functions that improve remote maintenance. A variety of information can be collected for maintenance systems without influencing control systems and productivity. Wiring Diagrams Control System Maintenance System DC static converter (non-isolated) Detection circuit V0 V0 G0 G0 List of Functions : Supported; ­: Not supported. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON DRT2-D16S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON DRT2-D16S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag