Manual abstract: user guide OMRON E2E-YDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] (at 500 VDC) between current carry parts and case 10 to 55 Hz, 1. 5 mm double amplitude for 2 hours each in X, Y, and Z directions Destruction: 1, 000 m/s2 for 10 times each in X, Y, and Z directions IEC IP68 *3 Pre-wired models (standard length 2 m) Approx. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing object and the sensing distance set is half of the maximum sensing distance. Short circuit protection types are available. OMRON test method Conditions: Less than 10 m natural state under water (1) It is not flooded underwater with two atmospheric pressure for 1 hour. [. . . ] Do not use the Proximity Sensor in an environment with chemical gas (e. g. , strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor. R VS/(10 ­ I) (k) P > VS2/R (mW) P:The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor. ) I:Load current (mA) The following resistors are recommended. 100 VAC (supply voltage): A resistor with a resistance of 10 k maximum and an allowable power of 3 W minimum 200 VAC (supply voltage): A resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum If these resistors generate excessive heat, use a resistor with a resistance of 10 k maximum and an allowable power of 5 W minimum at 100 VAC and a resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum at 200 VAC instead. E2E-@Y/E2F-@Y 9 Precautions for AC 2-wire Proximity Sensors in Operation Connection Model AC 2-wire Connection type AND (serial connection) Method Description If 100 or 200 VAC is imposed on the Proximity Sensors, VL (i. e. , the voltage imposed on the load) will be obtained from the following. of Proximity Sensors) (V) Incorrect Load Correct Load Therefore, if VL is lower than the load operating voltage, the load will not operate. A maximum of three Proximity Sensors can be connected in series provided that the supply voltage is 100 V minimum. Load Vs × 100 V OR (parallel connection) Incorrect A Load In principle, more than two Proximity Sensors cannot be connected in parallel. Provided that Proximity Sensor A does not operate with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel. In this case, however, due to the total leakage current of the Proximity Sensors, the load may not reset properly. VAC power supply VS B Correct A B Load It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason. When Proximity Sensor A is ON, the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the load current flows into Proximity Sensor A, and when one of the sensing objects is close to Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Proximity Sensor B is 10 V, which is too low. When Proximity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON. Then, Proximity Sensor A as well as Proximity Sensor B will be OFF for approximately 10 ms, which resets the load for an instant. To prevent the instantaneous resetting of the load, use a relay as shown on the left. 10 Cylindrical Inductive Sensor for AC Power Supply Dimensions E2F-X1R5Y CAD file E2F_03 E2F-X2Y CAD file E2F_05 15 dia. Indicator Two, tightening nuts Two, washers Note: Vinyl-insulated round cord, 3. 5 dia. , 3 cores (0. 12 dia. x 13); Standard length: 2 m Indicator Two, tightening nuts Note: Oil-and vibration-resistant, vinyl-insulated round cord, 6 dia. , 0. 5 dia. x 2 cores; Standard length: 2 m The cord can be extended up to 200 m in an independent metal conduit. E2F-X5Y CAD file E2F_06 E2F-X10Y CAD file E2F_01 47 (57) 40 (50) 29 (38) Indicator Two, tightening nuts Note: Oil-and vibration-resistant, vinyl-insulated round cord, 6 dia. , 0. 5 dia. x 2 cores; Standard length: 2 m The cord can be extended up to 200 m in an independent metal conduit. Indicator Two, tightening nuts Note: Oil-and vibration-resistant, vinyl-insulated round cord, 6 dia. , 0. 5 dia. x 2 cores; Standard length: 2 m The cord can be extended up to 200 m in an independent metal conduit. Mounting Hole Dimension F Model F (mm) E2F-X1R50 E2E-@Y/E2F-@Y 11 Pre-wired Models (Shielded) Fig. 13 3 40 36 8 7 Pre-wired Models (Unshielded) Fig. M8 × 1 Operation Indicator (red) Two clamping nuts Toothed washer M8 × 1 Operation indicator (red) Two clamping nuts Toothed washer 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0. 3 mm2, Insulator diameter: 1. 3 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0. 3 mm2, Insulator diameter: 1. 3 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). Fig. [. . . ] IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS CATALOG ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2E-Y

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E2E-Y will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag