User manual OMRON E3S-C DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3S-C. We hope that this OMRON E3S-C user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3S-C.


OMRON E3S-C DATASHEET: Download the complete user guide (1061 Ko)

Manual abstract: user guide OMRON E3S-CDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] You need not worry about malfunctions due to noise, either. High shock resistance of 1, 000 m/s2 The industry's top-class photoelectric sensor features shock resistance of 1, 000 m/s sor at rated values, and vibration resistance of as high as 10 to 2, 000 Hz. 2, which is as high as that of a proximity sen- Mutual interference prevention enhanced (Retroreflective, diffuse reflective models) Fuzzy inference is introduced into the mutual interference prevention for the first time in the industry. This prevents a malfunction due to mutual interference, enabling two sensors to be mounted closely side by side. Lineup of M12 metal connector joint type models Lineup of water/oil/shock-resistant M12 metal connector joint type models are available. This series ensures ease of sensor replacement during maintenance. Easy optical axis alignment OMRON's original "automatic position compensation system" minimizes misalignment of mechanical and optical axes to merely ±2°. The optical axis is aligned perfectly by only installing the sensor. E3S-C A-101 Application Drill breakage detection Detection of engine block IP67 ensures a worry-free use in oil mist environment. Ordering Information Sensors Sensor type Shape Connection method Pre-wired Sensing distance Red light Infrared light Model E3S-CT11 E3S-CT11-M1J E3S-CT16 Horizontal Model Junction connector Plug-in connector Through-beam 30m Vertical Model Pre-wired Junction connector Plug-in connector Pre-wired E3S-CT61 E3S-CT61-M1J E3S-CT66 E3S-CR11 E3S-CR11-M1J E3S-CR16 Horizontal Model Junction connector Plug-in connector Retroreflective Models Vertical Model Pre-wired Junction connector Plug-in connector Pre-wired 3m E3S-CR61 E3S-CR61-M1J E3S-CR66 700mm 2m 700mm 2m 700mm 2m E3S-CD11 E3S-CD12 E3S-CD11-M1J E3S-CD12-M1J E3S-CD16 E3S-CD17 E3S-CD61 E3S-CD62 E3S-CD61-M1J E3S-CD62-M1J E3S-CD66 E3S-CD67 Horizontal Model Junction connector Plug-in connector Diffuse-reflective Pre-wired 700mm 2m Vertical Model Junction connector Plug-in connector 700mm 2m 700mm 2m Accessories (Order Separately) Slits Slit width Width 0. 5 mmx11 mm Width 1 mmx11 mm Width 2 mmx11 mm Width 4 mmx11 mm Sensing distance 1. 8 m 3. 5 m 7m 15 m Minimum sensing object (typical) 0. 5 mm dia. [. . . ] Pin 2 is open. E3S-C A-105 E3S-C Characteristic data (typical) Operating Range Through-beam E3S-CT#1(-M1J) 500 Retroreflective Models E3S-CR#1 (-M1J) + E39-R1 (supplied reflector) Excess gain ratio 500 Reflector: E39-R1 300 Diffuse-reflective E3S-CD##(-M1J) Excess gain ratio 500 Sensing object: White paper 300 E3S-CD#1 100 50 30 E3S-CD#2 Excess gain ratio 300 100 50 30 100 50 30 10 5 3 Operation 1 level 0 10 5 3 Operation 1 level 0 10 5 3 Operation 1 level 0 10 20 30 40 1 2 3 4 1 2 3 Distance (m) Distance (m) Distance (m) Nomenclature: (Horizontal type) Control unit cover Control unit cover (Vertical type) Stability indicator (green) Light indicator (red) S L Stability indicator (green) NPN and PNP output selector * 1 S PNP D ON L SENS Light indicator (red) Sensitivity adjuster NPN L ON Min Max Min Max Sensitivity adjuster L-ON and D-ON selector * 2 SENS PNP D·ON NPN and PNP output selector * 1 NPN L·ON L-ON and D-ON selector * 2 Model E3S-CD12 *1. The output transistor can be selected with the NPN/PNP output selector. Note: The through-beam and retroreflective models are different in sensitivity adjuster shape. Operation Sensitivity adjustment (diffuse reflective model, light-ON) Sequence Detection state Sensing object Photoelectric Sensor Sensitivity adjuster (A) Indicator state ONÆOFF OFFÆON Adjustment procedure Place a sensing object in the predetermined position, turn the sensitivity adjuster clockwise (increase sensitivity) until the incident indicator (red) is turned ON, and define this position as (A). Remove the sensing object, turn the sensitivity adjuster further clockwise until the incident indicator (red) is turned ON by a background object, and define this position as (B). Turn the sensitivity adjuster counterclockwise (decrease sensitivity) from (B) until the incident indicator (red) is turned OFF, and define this position as (C). When there is no background object, define the maximum adjuster position (Max) as (C). Set the adjuster in the middle of positions (A) and (C) (optimum sensitivity setting). Also make sure that the stability indicator (green) is turned ON when there is an object and when there is no object. · When the sensor cannot be set on the mechanical axis, move the E3S-C vertically and/or horizontally and set it in the center of the area where the incident indicator is turned ON. Make sure that the stability indicator is ON. Optical axis Mounting axis Four M4 optical axis lock holes E3S-C A-107 E3S-C Optical axis position of through-beam model Unlike the conventional product, the through-beam model has two lenses, but the one actually used is as shown below. When fitting the slit, use it after matching the slit hole with the used lens. Lens in use. Miscellaneous Oil resistance/chemical resistance · Though E3S-C has a high oil resistance, it may not be able to exhibit its performance depending on the oil type. · Regarding the oil resistance of E3S-C, it has passed tests on the oils given in the following table. Refer to the table for examining the oil to be used. Testing JIS classioil classification fication Product name Velocity No. 2ac Yushiroken EC50T-3 Yushiron Lubic HWC68 Gryton 1700D Yushiroken S50N --Dynamic viscosity (mm2/s) at 40°C 2. 02 Not less than 10 to less than 50 Less than 10 7 to 9. 5 7 to 9. 9 7 to 9. 2 7 to 9. 8 PH Lens not in use. Lens not in use. Lubricant Water-insoluble coolant --Class 2 No. 1 --- Water Resistance To ensure water resistance, tighten the operation panel cover screws to 0. 34 Nm to 0. 54 Nm torque. Watersoluble coolant Class W1 No. The E3S-C was immersed in the oils in the above table at 50°C for 240 hours, and passed the test of 100-M or more insulation resistance. [. . . ] (18 x 0. 12 dia. ); standard length: 0. 3 m M12 x 1 16 dia. 18. 5 50 Light indicator (red) M3 x 5 Vinyl-insulated round cable with three conductors, 4 dia. (18 x 0. 12 dia. ); standard length: 2 m * 3 20 20. 4 22. 2 Stability indicator (green) 9. 2 4. 2 Mounting holes 2-M4 20 25. 4 4. 2 8. 3 Stainless steel (SUS304) Lens (17 x 11) Receiver 2. 2 6. 2 38. 2 23 4 9 1 18 (A)*1 29. 5 17. 3 9. 3 Optical axis Emitter 2-M4 1. 5 20. 8 25. 4 * Note: Mounting bracket can be attached to side A. E3S-C A-109 E3S-C Vinyl-insulated round cable with three conductors, 4 dia. (18¥0. 12 dia. ); standard length: 0. 3 m M12¥1 Retro/diffuse reflective model (vertical model) E3S-CR61(-M1J) E3S-CD61(-M1J) E3S-CD62(-M1J) Vinyl-insulated round cable with three conductors, 4 dia. (18 x 0. 12 dia. ); standard length: 0. 3 m Junction connector models (-M1J) M12 x 1 With mounting bracket 16 dia. 57 Receiver 20. 8 5 9 2. 4 Emitter Vinyl-insulated round cable with three conductors, 4 dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3S-C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3S-C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag