User manual OMRON E3ZM DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3ZM. We hope that this OMRON E3ZM user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3ZM.


OMRON E3ZM DATASHEET: Download the complete user guide (453 Ko)

Manual abstract: user guide OMRON E3ZMDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] This does not apply to BGS Reflective Models, however, because they require 4 pins. Values in parentheses indicate the minimum required distance between the Sensor and Reflector. . Accessories Reflectors Name E3ZM-R Sensing distance (typical) *1 3 m [100 mm] (rated value) 4 m [100 mm] (rated value) 5 m [100 mm] 2. 5 m [100 mm] 3. 5 m [100 mm] 3 m [100 mm] 1. 5 m [50 mm] 700 mm [150 mm] 1. 1 m [150 mm] 1. 4 m [150 mm] Model E39-R1 E39-R1S E39-R2 E39-R9 E39-R10 E39-R1K E39-R3 E39-RS1 E39-RS2 E39-RS3 Quantity 1 1 1 1 1 1 1 1 1 1 Remarks Reflector Fog preventing Small reflector Tape Reflector Reflectors are not provided with Retro-reflective models. Values in parentheses indicate the minimum required distance between the Sensor and Reflector. When using a Reflector without a rated value, use 0. 7 times typical value as a guideline for the sensing distance. [. . . ] The appropriate tightening torque is 0. 3 to 0. 4 N·m. E3ZM A-11 Precautions for Safe Use Do not install the Sensor in the following locations. (1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The load shortcircuit protection will operate when the current flow reaches 1. 8 times the rated load current. When using an L load, use an inrush current of 1. 8 times the rated load current or higher. Connecting and Mounting (1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0. 3 mm2 and less than 100 m long. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6) Mount the Sensor either using the bracket (sold separately) or on a flat surface. (7) Be sure to turn OFF the power supply before inserting or removing the connector. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. When disposing of the Sensor, treat it as industrial waste. Mounting Diagram Mounting Bracket (sold separately) E39-L104 Use a mounting torque of 0. 5 N·m max. Resistance to Detergents, Disinfectants, and Chemicals · Performance is assured for typical detergents and disinfectants, but performance may not be maintained for some detergents and disinfectants. · The E3ZM passed testing for resistance to detergents and disinfectants performed using the items in the following table. Refer to this table when considering use of detergents and disinfectants. Category Product name Sodium hydroxide (NaOH) Phosphoric acid (H3PO4) Sodium hypochlorite (NaCIO) Hydrogen peroxide (H2O2) Alkaline foam detergent Acidic foam detergent P3-topax-66s (Manufactured by Ecolab) P3-topax-56 (Manufactured by Ecolab) P3-oxonia active 90 (Manufactured by Ecolab) Disinfectant Concentration 1. 5 % 2. 5 % 0. 3 % 6. 5 % 3. 0 % 5. 0 % 1. 0 % Temperature 70 °C 70 °C 70 °C 25 °C 25 °C 70 °C 70 °C 25 °C Time 240 h 240 h 240 h 240 h 240 h 240 h 240 h 240 h Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Power Supply Reset Time The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Potassium hydroxide (KOH) 1. 5 % Chemical Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. TEK121 (Manufactured by ABC 1. 1 % 25 °C 240 h Compounding) Note: The Sensor was immersed in the chemicals, detergents, and disinfectants listed above at the temperatures in the table for 240 hours and then passed an insulation resistance of 100 M min. A-12 Standard Photoelectric Sensors Dimensions Sensors Through-beam Models Pre-wired Models E3ZM-T61(-G0) E3ZM-T81(-G0) E3ZM-T63(-G0) E3ZM-T83(-G0) Emitter 10. 8 Power indicator (green) 21 7. 5 (Unit: mm) Optical axis *4-dia. vinyl-insulated round cable with 3 conductors, Standard length: 0. 3 m 1 4 20. 6 15. 5 32. 2 31 25. 4 M12 x 1 2 3 Two, M3 4-dia. vinyl-insulated round cable with 2 or 3 conductors (Conductor cross section: 0. 2 mm2, Insulator diameter: 1. 1 mm), Standard length: 2 m Terminal No. 1 2 3 4 Specifications +V Light emission stop input (-G0 only) 0V --- Receiver Mode selector switch Sensitivity adjuster 10. 8 Operation indicator (yellow) Stability indicator (green) M12 Pre-wired Connector (E3ZM- [. . . ] CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3ZM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3ZM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag