User manual OMRON E3ZM-B DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3ZM-B. We hope that this OMRON E3ZM-B user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3ZM-B.


OMRON E3ZM-B DATASHEET: Download the complete user guide (1945 Ko)

Manual abstract: user guide OMRON E3ZM-BDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] (15 mA at 30 VDC) For all transparent objects E3ZM-B_T 0 to 500 mm (Using E39-RP1); min distance to reflector: 100 mm 25 mA max. Load power supply voltage: 30 VDC max. , Load current: 100 mA max. (Residual voltage: 2 V max. ) Open-collector output (NPN/PNP output depending on model) Light-ON/Dark-ON selectable by wire Light-ON/Dark-ON switch selectable Reversed power supply polarity, load short-circuit protection, mutual interference prevention, reversed output polarity protection Operation or reset: 1 ms max. Teach button Operating: -40 to 60°C (*1), Storage: -40 to 70°C (with no icing or condensation) 20 M min. at 500 VDC 1, 000 VAC, 50/60 Hz for 1 min Destruction: 10 to 55 Hz, 1. 5-mm double amplitude for 2 hours each in X, Y, and Z directions Destruction: 500 m/s2 3 times each in X, Y, and Z directions IEC 60529: IP67, DIN 40050-9: IP69K (*2) Pre-wired cable (standard length: 2 m) or M8 4-pin connector Operating indicator (yellow), Stability indicator (green), and Teaching indicator (red) Pre-wired models: Approx. [. . . ] For ordering pigtail connectors contact your OMRON representative. Click! Highest protection 2. Using M8 connector models Connector models are often preferred to allow an easy exchange of the sensor. When using M8 connector models, observe the recommended mounting torque (see page 10). A too tight connection may damage the sealing ring and a loose connection may provide an opportunity for water to enter into the connection between sensor and connector. RECOMMENDATION: To obtain the correct mounting torque, a torque wrench may be used. Fast exchange E3ZM-B 9 Safety Precautions WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Low-temperature Environments Do not touch the metal surface with your bare hands when the temperature is low. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Otherwise, the optical properties and degree of protection may be degraded. Also, do not use high-pressure water with a level of pressure that exceeds the stipulated level. The Sensor surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Cable Bending Do not bend the cable in temperatures of -25°C or below. Otherwise, the cable may be damaged. CAUTION Do not use the product with voltage in excess of the rated voltage. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. When using an XS3F connector, be sure to tighten the connector lock by hand or preferably with a torque wrench; do not use other tools. If too much tightening torque is applied the degree of protection will not be maintained. If the tightening is insufficient, the degree of protection will not be maintained and the sensor may become loose due to vibration. When using another, commercially available connector, follow the usage and tightening torque instructions provided by the manufacturer. 10 Transparent object sensor Dimensions Note: All units are in millimeters unless otherwise indicated. Sensors Pre-wired models E3ZM-B61 E3ZM-B81 10. 8 Operation indicator (yellow) Optical axis 9 1. 2 Stability indicator (green) 21 13. 2 5. 7 3. 2 M12 Pre-wired Connector (E3ZM-vinyl-insulated round cable with 3 conductors, Standard length: 0. 3 m 1 4 Teaching button Teaching indicator (red) 3 M12 x 1 2 Terminal No. [. . . ] CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3ZM-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3ZM-B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag