User manual OMRON E5AR-T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5AR-T. We hope that this OMRON E5AR-T user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5AR-T.


OMRON E5AR-T : Download the complete user guide (6053 Ko)

You may also download the following manuals related to this product:

   OMRON E5AR-T BROCHURE (3150 ko)
   OMRON E5AR-T DATASHEET (1793 ko)

Manual abstract: user guide OMRON E5AR-T

Detailed instructions for use are in the User's Guide.

[. . . ] H201-E1-01 E5AR-T E5ER-T Programmable Digital Controller USER'S MANUAL Introduction OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. This manual describes the functions, performance, and application methods needed for optimum use of the E5AR-T/ER-T Programmable Digital Controllers. Please observe the following items when using the E5AR-T/ER-T Programmable Digital Controllers. · This product is designed for use by qualified personnel with a knowledge of electrical systems. [. . . ] This function is disabled, however, for channels 2 to 4 during coordinated operation. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Program SP Mode Fixed SP Mode Functions and Operations Program SP · When the event input is ON, the program SP (PSP) is used as the SP. The event input must be reset before this function can be activated again. · The Program SP function creates an operation command that applies to one specific channel. This function is disabled, however, for channels 2 to 4 during coordinated operation. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Program SP Mode Remote SP · When the event input is ON, the remote SP (RSP) is used as the SP. The event input must be reset before this function can be activated again. · The Remote SP function creates an operation command that applies to one specific channel. This function is disabled, however, for channels that do not support the remote SP function. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Remote SP Mode 5-44 5. 8 Using Event Inputs Fixed SP · When the event input is ON, the fixed SP (FSP) is used as the SP. The event input must be reset before this function can be activated again. · The Fixed SP function creates an operation command that applies to one specific channel. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Fixed SP Mode Hold (ON)/Clear Hold (OFF) · When the event input is ON, the program is on hold and this status is held until the event input changes to OFF. · The Hold (ON)/Clear Hold (OFF) function creates an operation command that applies to one specific channel. During coordinated operation, however, the operation command applies to all channels. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Clear Hold Mode Hold Mode Advance · When the event input is ON, the segment is advanced to the beginning of the next segment. The event input must be reset before this function can be activated again. · The advance function creates an operation command that applies to one specific channel. During coordinated operation, however, the operation command applies to all channels. · Operation is as follows based on the ON/OFF status of the event input: Event input Description Advance Mode 5-45 Functions and Operations Section 5 Functions and Operations Back · When the event input is ON, the program returns to the start of the current segment being executed. The event input must turn OFF once before this function can be used again. · The back function creates an operation command that applies to one specific channel. [. . . ] The data type is the same as the display value. Setting Lists A-43 Appendix Appendix A-44 Common Input Type 1 Input Type 2 Input Type 3 Input Type 4 SP Upper Limit SP Lower Limit Closed/Floating Control Mode (*1) Temperature Unit 1 Temperature Unit 2 Temperature Unit 3 Temperature Unit 4 Scaling Display Value 1 Scaling Display Value 2 Scaling Input Value 1 Scaling Input Value 2 Common CH CH CH Common CH Decimal Point Position No assignment Temperature input - - - - - O (*4) O (*4) O O O O (*5) O (*5) - - O - - - O - - - - - - - O - - - - - - - - - O - - - - - - - - - - - O O O O - O O (*9) O O O O - - - O (*8) - - - - - - - - - - - - O (*5) O (*5) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Temperature input O (*2) - · No assignment · Analog input - Position-proportional control - O (*3) O (Scaling display value 1) - - - O (*5) O (*5) - - O O - - O (*5) O O (*6) O (*3) O (*3) - - - O (*5) O (*5) - - O O - - O (*5) O O (*6) - - - - - - O - - - - - - - O (*6) O O (*5) - - O O - - O (*5) O (*5) - - - Changed parameter Appendix Related parameters Condition for not initializing parameters Scaling Input Values 1 and 2 SP Upper Limit O (Upper limit of sensor setting range or Scaling Display Value 2) O (Upper limit of sensor setting range) O (Scaling Display Value 2) SP Lower Limit O (Lower limit of sensor setting range or Scaling Display Value 1) O (Lower limit of sensor setting range) O (Scaling Display Value 1) Automatic Selection Range Upper Limit (PV/DV/SP) (PID 1 to 8) Remote SP Upper Limit O (Upper limit of input setting range or Scaling Display Value 2) O (Upper limit of input setting range) O (Scaling Display Value 2) Remote SP Lower Limit O (Lower limit of input setting range or Scaling Display Value 1) O (Lower limit of input setting range) Control/Transfer Output Assignment 1 to 4 Event Input Assignment 1 to 10 Auxiliary Output Assignment 1 to 4 Transfer Output to 1 to 4 Upper Limit Transfer Output to 1 to 4 Lower Limit Manual MV (Standard/Heating/Cooling) SP Mode Fixed SP Dead Band MV at Reset (Standard/Heating/Cooling) MV at PV Error (Standard/Heating/Cooling) Input Adjustment Values 1 and 2 Input Correction 1 and 2 Alarm Values 1 to 4 (Alarm Set 1 to 4) Alarm Upper Limit 1 to 4 (Alarm Set 1 to 4) Alarm Lower Limit 1 to 4 (Alarm Set 1 to 4) Integral Time Initialization Due to Changing Parameter Settings MV Upper Limit (PID 1 to 8) MV Lower Limit (PID 1 to 8) MV Display Selection Bar Graph Display Item Number of Enabled Channels PV Dead Band Parameters that are initialized when the settings of related parameters are changed are listed in the Related parameter column. Meaning of Symbols: O: Initialized, -: Not initialized, : Added channels initialized Manual MV Initial Value (Standard/Heating/Cooling) Common Input Type 1 Input Type 2 Input Type 3 Input Type 4 SP Upper Limit SP Lower Limit Control Mode (*1) Program Time Unit Temperature Unit 1 Temperature Unit 2 Temperature Unit 3 Temperature Unit 4 Number of Enabled Channels Number of Segments (*10) Scaling Display Value 1 Scaling Display Value 2 Scaling Input Value 1 Scaling Input Value 2 Common CH CH Common Common Common Common Common Common Changed parameter Independent Operation/ Coordinated Operation Step Time/Rate of Rise Programing (*10) Related parameters No assignment Temperature input - - O (*11) O (*11) - O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O O (*11) - - O (*11) O (*11) O (*11) O (*11) - - O (*11) - - O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) - - O (*11) - - O (*11) O (*11) O (*11) O (*11) O (*11) O (*11) - - - O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) - - O (*10) - - O (*11) O (*11) O (*10) O (*11) O (*11) O - - O - O (*13) - - - - O O - - - O - - - - - - - - - - - - - - - - - - O - - - - - - - - - - - - (*13) O - O (*13) - - - - O O - - - - O - - - - - - - - (*13) - - - - (*13) - - - - · No assignment · Analog input - Position proportional control - - - - - - - - - O (*12) - - - - - - - - - - - O (*15) - - Condition for not initializing parameters - O O O (*10) - O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) O (*10) - - O (*10) - - PV Start Program No. Number of Segments Used Segment Editing Segment Set Point Segment Time Segment Rate of Rise Wait Segment Output 1 to 10 PID Set Number Alarm Set Number Wait Band Upper Limit Wait Band Lower Limit Program Repetitions Program Link Destination SP Mode Set Point Offset Time Signal 1 to 6 Set Segment 1 to 3 Time Signal 1 to 6 ON Segment 1 to 3 Time Signal 1 to 6 OFF Segment 1 to 3 Operation at Power ON End Condition Setting Lists A-45 Appendix Appendix *1: When the control mode is changed, added channels are initialized in the same way as the related parameters for the Input Type parameter ( on the previous page). *3: If this is PV or SP based on the PID Set Automatic Selection Data parameter, then (setting upper limit + setting range × 0. 1); if it is DV, then (setting range × 1. 1). *4: Initialized only if the control mode is changed to proportional control (Temperature: Initializes to upper and lower limits of sensor setting range. Analog: Initializes to values set for Scaling Display Values 1 and 2 parameters). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5AR-T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5AR-T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag