User manual OMRON E5CS-X DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5CS-X. We hope that this OMRON E5CS-X user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5CS-X.


Mode d'emploi OMRON E5CS-X
Download
Manual abstract: user guide OMRON E5CS-XDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Temperature unit (selectable) Measurement unit Control mode Without a a ou alarm With a a alarm Relay output Voltage output Relay output Voltage output ON/OFF or PID E5CS-RGX E5CS-QGX E5CS-R1GX E5CS-Q1GX THE element interchangeable thermistor 600 . . . . . . . . . . . . ­50 ­50 Standard temperature ranges (switch selectable) 0 1 2 °C 3 4 1 5 6 7 °F 8 9 The functions can be factory-set for shipment as shown in the table below, depending on the suffix attached to the model number when you place your order. Two suffixes are selectable: "-DIN" or "-F". Example: E5CS-RKJX-DIN Suffix Suffix S a da d e pe a u e Standard temperature range K(CA)/J(IC) PT THE Temperature unit (selectable) Control mode Proportional pe od opo o a period Control output Input shift Temperature sensor standard Alarm mode Relay output Voltage output Reverse operation Cannot be set JIS (ISO) 2 (upper-limit) None 2 (0 to 400) 3 (0. 0 to 99. 9) 1 (­50 to 50) °C ON/OFF 20 s 0 -DIN 8 (0 to 400) 3 (0. 0 to 99. 9) 1 (­50 to 50) °C ON/OFF 20 s 2s Reverse operation Cannot be set DIN 2 (upper-limit) Reverse operation Cannot be set JIS (ISO) 2 (upper-limit) -F 2 (0 to 400) 3 (0. 0 to 99. 9) 1 (­50 to 50) °F ON/OFF 20 s 0 The functions can be factory-set in accordance with your needs. [. . . ] Platinum Resistance Thermometer Type Select the desired temperature range using the temperature range selector switch (rotary DIP type). Eight or nine temperature ranges can be selected depending on the model. The set temperature is automatically changed when the temperature range is changed. Be sure to confirm the set temperature. Temperature range selector switch Alarm mode selector switch Do not set the selector switch to "9. " Doing so will result in the error message "FFF" or "­ ­ ­" being displayed. The unit in which the temperature can be set is multiplied by 10 when the temperature range is changed from 0. 0 to 50. 0 or 0. 0 to 99. 9 to a range in which the temperature can be set in 1° units. 5 ON ON 6 P Function Protect X P ON OFF 1 X 2 1 3 2 4 3 5 4 6 5 6 7 8 --Control mode Proportional period Control output Input shift PID ON/OFF 2s 20 s Normal Reverse Setting enabled Setting disabled Temperature sensor standard Scale indicator (selectable) DIN JIS °F °C Not used ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Note: The selector switch is factory-set to "2. " The triangular mark Y indicates the set temperature. Y denotes the set value value within the temperature range. Operation of Standby Sequence Alarm output set with standby sequence will operate in the way shown below when the temperature rises above the upper-limit. Alarm output set with standby sequence will operate in the way shown below when the temperature drops below the upper-limit. 7 E5CS-X Control Mode Selection ON/OFF Control Pin 1 of the internal DIP switch is factory-set to OFF, so the Temperature Controller performs ON/OFF control. E5CS-X Set pin 3 to ON when the Temperature Controller is used to control a cooling device, such as a freezer. ON ON ON ON P X 1 2 3 4 5 6 P X ON 1 2 3 4 5 6 Pin 1 OFF: Temperature Controller performs ON/OFF. ON OFF Set temperature Control output OFF Set temperature Control output PID Control Set pin 1 of the internal DIP switch to ON to make the Temperature Controller perform PID control. Determining Control Output Operation If the Temperature Controller is used to control a heater, the control output can be set to perform reverse (inverted) operation. Set pin 3 of the control output mode selector switch to OFF. ON ON ON P X 1 2 3 4 5 6 Pin 1 ON: Temperature Controller performs PID control. ON P X ON 1 2 3 4 5 6 Determining Proportional Period Set pin 2 of the DIP switch to OFF to select a proportional period of 20 seconds. This is used when PID control is performed with the relay output of the Temperature Controller, or when using an external relay or contactor. Reverse output OFF Set temperature ON ON Conversely, if the Temperature Controller is used to control a cooling device such as a freezer, set pin 3 to ON. ON P Control output OFF 20 seconds ON X ON 1 2 3 4 5 6 P X ON Normal output OFF Set temperature 1 2 3 4 5 6 When a quick response is required, set pin 2 to ON to select a proportional period of 2 seconds. Even when a solid-state relay (SSR) is used, only set the 2-second proportional period where quick response is essential. With a relay control output, a proportional period of 2 seconds will greatly reduce the service life of the relay. ON ON P Control output ON OFF X 1 2 3 4 5 6 2 seconds When power is first turned ON, the proportional band is set to 3%. The optimum proportional band, however, is automatically calculated and set within the range 3% to 20%, according to the changes in the temperature of the controlled system. This automatic adjustment of the proportional band is possible regardless of whether the controlled system is a heating or cooling system. When the power is turned OFF once, and then ON again, the control starts with the previous proportional band. A new proportional band, however, is automatically calculated and set. The calculation of the proportional band is not carried out, however, if the temperature of the controlled system changes at a rate faster than 7. 5% of the full scale per 2 seconds (e. g. , faster than 3. 75°C per second with a full scale of 100°C). In this case, the previously calculated and set proportional band is used. The Temperature Controller is provided with an overshoot prevention function that suppresses the second overshoot and those that follow to a level less than the initial overshoot. 8 E5CS-X Input Shift Function This function is used to shift the value displayed in the main display from the value actual measured by a desired amount. This powerful feature can be used for "fine tuning" compensation, while leaving the set temperature unaffected. The input shift function is activated by setting pin 4 of the internal DIP switch to ON. [. . . ] Push the adapter as close as possible to the front panel of the Temperature Controller to eliminate the gap between them. Then, secure the adapter with screws as shown in the figure below. Solder-dipped Lead Wires Strip the lead wire 6 to 12 mm and carefully arrange the wire tip. Removal Loosen the screws on the adapter and push the hook open to remove the adapter. Do not tighten the terminal screw with excessive force. Input Sensor Connection Hook Screw The lead wires connecting the sensor to the Temperature Controller must be separated from power lines and load lines wherever possible, to prevent them from being induced by noise. Use the specified compensating conductors for the thermocouple type Temperature Controllers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5CS-X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5CS-X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag