User manual OMRON E5CSV BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5CSV. We hope that this OMRON E5CSV user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5CSV.


Mode d'emploi OMRON E5CSV
Download

You may also download the following manuals related to this product:

   OMRON E5CSV DATASHEET (351 ko)

Manual abstract: user guide OMRON E5CSVBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Input type T: Thermocouple/platinum resistance thermometer (multi-input) 4. Power supply voltage Blank: 100 to 240 VAC D: 24 VAC/VDC 5. Terminal cover 500: Finger protection cover Ordering Information List of Models Size 1/16 DIN 48 x 48 x 78 mm (W x H x D) Power supply voltage 100 to 240 VAC 24 VAC/VDC Number of alarm points 1 1 Relay Voltage (for driving SSR) Relay Voltage (for driving SSR) Control output TC/Pt multi-input Incl. terminal cover E5CSV-R1T-500 E5CSV-Q1T-500 E5CSV-R1TD-500 E5CSV-Q1TD-500 Accessories (Order Separately) Protective Front Cover Type Hard Protective Cover Model Y92A-48B 4 Temperature Controllers E5CSV Temperature Controllers E5CSV 1 Specifications Ratings Supply voltage Operating voltage range Power consumption Sensor input Control output Relay output 100 to 240 VAC, 50/60 Hz 85% to 110% of rated supply voltage 5 VA SPST-NO, 250 VAC, 3A (resistive load) ON/OFF or 2-PID (with auto-tuning) SPST-NO, 250 VAC, 1A (resistive load) Digital setting using front panel keys (functionality set-up with DIP switch) 3. 5 digit, 7-segment digital display (character height: 13. 5 mm) and deviation indicators · · · · · · · Setting change prohibit (key protection) Input shift Temperature unit change (° C/° F) Direct/reverse operation Control period switching 8-mode alarm output Sensor error detection 3 VA/2 W Multi-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100 24 VAC/VDC, 50/60 Hz Voltage output (for driving the SSR) 12 VDC, 21 mA (with short-circuit protection circuit) Control method Alarm output Setting method Indication method Other functions Ambient temperature Ambient humidity Storage temperature -10 to 55° C (with no condensation or icing) 25% to 85% -25 to 65° C (with no condensation or icing) Characteristics Setting accuracy Indication accuracy (ambient temperature of 23° C) Influence of temperature Influence of voltage Hysteresis (for ON/OFF control) Proportional band (P) Integral time (I) Derivative time (D) Alarm output range Thermocouple (See note 1. ): (±0. 5% of indication value or ±1° C, whichever is greater) ±1 digit max. [. . . ] The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals 1 or 2 to ground. Otherwise, unwanted current paths will cause measurement errors. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity. 6 Temperature Controllers E5CSV Temperature Controllers E5CSV 3 Operation E5CSV Deviation indicators The indicator lights when the PV is greater than the SP and the indicator lights when the PV is less than the SP. The indicator (green) lights when the deviation is less than 1% FS (0. 25% FS for multi-input models). These indicators flash during ST (self-tuning)/AT (auto-tuning). PV, SP, Alarm Value, Input Shift Display The display switches each time the Key is pressed. Output indicator Lights when the control output is ON. Mode indicators The SP indicator lights when the setting temperature is being displayed. The ALM indicator lights when the alarm value 1 is being displayed. Alarm indicators ALM1 (Alarm 1): Lights when the alarm 1 output is ON. ALM2 (Alarm 2): For future use. Mode Key When the power is turned ON, normally the display will use the display items in the following order each time the Mode Key is pressed. Power ON Up Key Pressing the Up Key increases the SP/alarm value display. Keeping the Up Key pressed continues to increase the display value. When the internal protect switch is ON, press the Up Key while holding down the Lock Release Key. PV Press the SP Press the Alarm value 1 Press the Input shift value Key. Key. Down Key Lock Release Key When the protect switch is ON, the set value can be changed by pressing the Up and Down Keys while holding down the Lock Release Key. Pressing the Down Key decreases the SP/alarm value display. Keeping the Down Key pressed continues to decrease the display value. When the internal protect switch is ON, press the Down Key while holding down the Lock Release Key. Key. This item is not displayed when the Control Mode Switch 4 is OFF. Key. Press the Settings before Turning ON the Power E5CSV Remove the E5CSV from the case to make the settings. Insert the tool into the two tool insertion holes (one on the top and one on the bottom) and release the hooks. Tool insertion hole Flat-blade screwdriver (Unit: mm) 3. When inserting the E5CSV, check to make sure that the sealing rubber is in place and push the E5CSV toward the rear case until it snaps into position. While pushing the E5CSV into place, push down on the hooks on the top and bottom surfaces of the rear case so that the hooks are securely locked in place. The input indication range is the range that can be displayed for the control range (-99 to 1999). If the input is within the control range but exceeds the display range (-99 to 1999), values below -99 will be displayed as "[[[" and values above 1, 999 will be displayed as "]]]. " 2. If unit is changed to 1 degree when the SP and alarm value for the temperature range are displayed in 0. 1-units from 0. 0 to 199. 9 or 0. 0 to 99. 9, the values will be multiplied by 10 (e. g. , 0. 5 becomes 5). [. . . ] The previous name J-DIN has been changed to L in accordance with revisions to DIN standards. (3) Setting Input Shift Turn ON switch 4, and after turning ON the power, press the Mode Key until h0 (indicates input shift of 0) is displayed. Press the Up and Down Keys to set the shift value. ON Shift Example Input shift display h0 (no shift) h9 (+9° C shift) l9 (-9° C shift) Measured temperature 100° C 100° C 100° C Temperature display 100° C 109° C 91° C 1 2 3 4 5 6 Note: When control mode switch 4 is turned OFF (no input shift display), the input shift is not displayed but the shift value is enabled. To disable input shift, set the input shift value to h0. The shift range depends on the setting unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5CSV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5CSV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag