User manual OMRON E5EK-DRT DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5EK-DRT. We hope that this OMRON E5EK-DRT user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5EK-DRT.


Mode d'emploi OMRON E5EK-DRT
Download
Manual abstract: user guide OMRON E5EK-DRTDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The heater burnout alarm function can be used only when an ON/OFF Output Unit is used for the control outputs (heat). Be sure to specify the Current Transformer and Output Unit when ordering. Description Output Unit (order separately) E53-R E53-S E53-Q E53-Q3 E53-Q4 E53-C3 E53-C3D E53-V34 E53-V35 Note: Model Relay SSR Pulse (NPN) 12 VDC Pulse (NPN) 24 VDC Pulse (PNP) 24 VDC Linear (4 to 20 mA) Linear (0 to 20 mA) Linear (0 to 10 V) Linear (0 to 5 V) Specification The Digital Controller uses a dedicated, high-resolution Output Unit. The E53-C Current Output Unit for the E5jX cannot be used with the Digital Controller. Inspection Report The Digital Controller can be provided together with an Inspection Report. [. . . ] 20G), 3 times each in 6 directions (100 m/s2 (approx. 10G) applied to the relay) Destruction: 300 m/s2 min. 30G), 3 times each in 6 directions Operating: Storage: ­10°C to 55°C (with no icing)/3-year warranty period: ­10°C to 50°C ­25°C to 65°C (with no icing) Ambient temperature Ambient humidity Enclosure ratings Operating: 35% to 85% Front panel: NEMA4 for indoor use (equivalent to IP66) Rear case: IEC standard IP20 Terminals: IEC standard IP00 Non-volatile memory (number of writings: 100, 000 operations) Approx. 65 g Emission Enclosure: Emission AC Mains: Immunity ESD: Immunity RF-interference: Immunity Conducted Disturbance: Immunity Burst: EN55011 Group 1 class A EN55011 Group 1 class A EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) ENV50140: 10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse modulated, 900 MHz) ENV50141: 10 V (0. 15 to 80 MHz) (level 3) EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Memory protection Weight EMC Approved standards UL1092, CSA22. 2 No. 1010-1 Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC61010-1) Conforms to VDE0106/part 100 (Finger Protection), when the separately-ordered terminal cover is mounted. Note: 1. The indication accuracy of the K, T, and N thermocouples at a temperature of -100°C or less is ±2°C ±1 digit maximum. The indication accuracy of the B thermocouple at a temperature of 400°C or less is unrestricted. The indication accuracy of the R and S thermocouples at a temperature of 200°C or less is ±3°C ±1 digit maximum. The indication accuracy of the W thermocouple at any temperature is (±0. 3% of the indicated value or ±3°C, whichever is greater) ±1 digit maximum. The indication accuracy of the PLII thermocouple at any temperature is (±0. 3% or ±2°C, whichever is greater) ±1 digit maximum. The indication accuracy of the Pt at ­100. 0°C to 100. 0°C is ±0. 1% FS ±1 digit maximum. The sampling period of the standard model with CT and remote SP inputs is 250 ms. 4 E5EK-DRT Communication Characteristics Conforms to DeviceNet communications protocol. E5EK-DRT For details, refer to the CompoBus/D Operation Manual (W267) and E5EK CompoBus/D-type Digital Controller Operation Manual (H99). Connection forms Communications baud rate Communications media Communications distance 500 kbps Combination of multi-drop and T-branch connections (see note 1) 500 kbps, 250 kbps, or 125 kbps (set using the front panel keys) Special 5-wire cables (2 signal lines, 2 power lines, 1 shield line) Network length (see note 2): 100 m max. 64 nodes (including Master) 63 Slaves CRC error check, duplicate node address check 250 kbps 125 kbps Max. number of Slaves Error control checks Note: 1. External Terminating Resistor is required. 2. Indicates the maximum distance between nodes. The distance is less than 100 m when thin cables are used for the trunk lines. Output Unit Ratings and Characteristics Relay output SSR output Voltage output 5 A at 250 VAC (resistive load) 1 A at 75 to 250 VAC (resistive load) NPN: 40 mA at 12 VDC NPN: 20 mA at 24 VDC PNP: 20 mA at 24 VDC (with short-circuit protection) (with short-circuit protection) (with short-circuit protection) Linear current output Linear voltage output 4 to 20 mA, permissible load impedance: 600 max. , resolution: approx. [. . . ] No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less than 190 ms. This product has been tested by ODVA's authorized Independent Test Lab and found to comply with ODVA Conformance Test Software Version 2. 0-1. 00. 5 E5EK-DRT E5EK-DRT Dimensions Note: All units are in millimeters unless otherwise indicated. E5EK-DRT Panel Cutouts 60 min. 120 min. Note: Rear case width is 44 mm. Recommended panel thickness is 1 to 8 mm. Maintain the specified vertical and horizontal mounting space between each Unit. Units must not be closely mounted vertically or horizontally. Installation External Connection Relay output (E53-R) ON/OFF voltage output (E53-Q) Current output (E53-C3) Linear voltage output SSR output (E53-V34) (E53-S) 100 to 240 VAC, 50/60 Hz 0 to 10 V 4 to 20 mA 40 mA at 12 VDC Control output 1 Remote SP input 0 to 10 V 4 to 20 mA 40 mA at 12 VDC Control output 2 CT input 4 to 20 mA Auxiliary output 1 1 to 5 V, 0 to 5 V, 0 to 10 V Thermocouple Platinum resistance thermometer (B) Auxiliary output 2 4 to 20 mA, 0 to 20 mA Precautions For application precautions, refer to the CompoBus/D Operation Manual (W267) and E5EK CompoBus/D-type Digital Controller Operation Manual (H99). 6 E5EK-DRT E5EK-DRT 7 E5EK-DRT E5EK-DRT ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5EK-DRT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5EK-DRT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag