User manual OMRON E5ZE-8

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5ZE-8. We hope that this OMRON E5ZE-8 user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5ZE-8.


Mode d'emploi OMRON E5ZE-8
Download
Manual abstract: user guide OMRON E5ZE-8

Detailed instructions for use are in the User's Guide.

[. . . ] E5ZE-8 Multipoint Temperature Controller Communications Manual Produced December 2000 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. !DANGER !WARNING !Caution Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. [. . . ] number of active connections Item Object interface 1 Section Interface type Production trigger Transport type Transport class Not supported Not supported 1 Information Explicit Message Cyclic Server 3 1 ------Max. number of interfaces 62 Multi-vendor Applications Item Object interface 1 Attributes 1 2 3 4 5 6 7 8 9 12 13 14 15 16 17 Item Object interface 1 Services 05 0E 10 Item Object interface 2 Section Interface type Production trigger Transport type Transport class Item Object interface 2 Attributes 1 2 3 4 5 6 7 8 9 12 13 14 15 16 17 Item Object interface 2 Services 05 0E 10 State Instance type Transport class trigger Produced connection ID Consumed connection ID Initial comm. characteristics Produced connection size Consumed connection size Expected packet rate Watchdog time­out action Produced connection path length Produced connection path Consumed connection path length Consumed connection path Production inhibit time DeviceNet service Reset Get_Attribute_Single Set_Attribute_Single No No No State Instance type Transport class trigger Produced connection ID Consumed connection ID Initial comm. characteristics Produced connection size Consumed connection size Expected packet rate Watchdog time-out action Produced connection path length Produced connection path Consumed connection path length Consumed connection path Production inhibit time DeviceNet service Reset Get_Attribute_Single Set_Attribute_Single Information Polled I/O Cyclic Server 2 ID Contents Get (read) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1 ------Set (write) No No No No No No No No Yes No No No No No No No No No ID Contents Get (read) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Set (write) No No No No No No No No Yes No No No No No No Appendix A Value --00 (hexadecimal) 83 (hexadecimal) ----21 (hexadecimal) FFFF (hexadecimal) FFFF (hexadecimal) --01 or 03 00 --00 ----Parameter option Max. number of interfaces Value --01 (hexadecimal) 82 (hexadecimal) ----01 (hexadecimal) 1C00 (hexadecimal) 1200 (hexadecimal) --00 00 --00 ----- Parameter option 63 Multi-vendor Applications Item Object interface 3 Section Interface type Production trigger Transport type Transport class Item Object interface 3 Attributes 1 2 3 4 5 6 7 8 9 12 13 14 15 16 17 Item Object interface 3 Services 05 0E 10 State Instance type Transport class trigger Produced connection ID Consumed connection ID Initial comm. characteristics Produced connection size Consumed connection size Expected packet rate Watchdog time-out action Produced connection path length Produced connection path Consumed connection path length Consumed connection path Production inhibit time DeviceNet service Reset Get_Attribute_Single Set_Attribute_Single No No No Information Bit strobed I/O Cyclic Server 2 ID Contents Get (read) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Appendix A Max. number of interfaces 1 ------Set (write) No No No No No No No No Yes No No No No No No Value --01 (hexadecimal) 82 (hexadecimal) ----01 (hexadecimal) 0800 (hexadecimal) 0800 (hexadecimal) --00 00 00_00_00_00_00_00 00 00_00_00_00_00_00 --Parameter option 64 Part 2 Serial Communications This part of the manual provides information required to use RS232C communications through the RS-232C auxiliary setting jack on the Temperature Controller RS-232C Auxiliary Setting Jack and Remote I/O Data written with the remote I/O function is updated in the E5ZE every 200 ms. If different settings are made with the RS-232C auxiliary setting jack and remote I/O communications, the settings made with the RS-232C auxiliary setting jack will last only until the next time the value is refreshed for remote I/O communications. RS-232C Auxiliary Setting Jack and FINS Messages Data written for the RS-232C auxiliary setting jack and FINS message are both achieved using commands If different settings are made with the RS-232C auxiliary setting jack and a FINS message, the last command that was executed will determine the value of the setting. Saving Set Values Any data sent with DeviceNet is automatically saved and will remain in memory even if the power supply is turned OFF. Data set from the RS-232C auxiliary setting jack, however, will not be saved unless the Memory Write Command (WE) is executed before power is turned OFF. 65 SECTION 1 Serial Communications Control This section provides general information on serial communications and communications checks. 1-1 1-2 1-3 1-4 1-5 Communications Control Procedure . . 68 69 69 70 70 67 Communications Control Procedure Section 1-1 1-1 Communications Control Procedure The communications procedure of the E5ZE is a special conversation type. In each E5ZE system, all communications are initiated by the host computer of the system by sending a character string called command block to an E5ZE of the system. The E5ZE then sends a character string called response block back to the host computer, i. e. , each time a block is transmitted, the transmission right is also transferred. Each block begins with a start character, @, and the unit number of the E5ZE and ends with an FCS and a terminator. The E5ZE sends a response block back to the host computer whenever the host computer sends a command block to the E5ZE. The response block is processed by the host computer. @ Unit no. Header code Host system Text FCS Terminator Command block @ Unit no. Header code Text FCS Terminator Command block 4 s max. Header code Text FCS Terminator Response block 20 ms min. Note Command Block: Response Block: A block sent from the host system. (Character string) A block sent from the E5ZE. (Character string) The host computer must be set up to read the responses sent by the E5ZE. [. . . ] The fuzzy scale 1 value of a control point will be automatically adjusted according to the PID constants. The fuzzy scale 1 value can be changed manually after PID constants are set for the bank. Function 157 Fuzzy Scale 1 Read: Rk Setting Data Range Setting unit °C or °F Default Setting data 0. 1 °C 9999 0002 to 9999 °F Section 7-4 Command Setting data @ Unit x161 x16 0 W k Bank Control point 0 0 x102 Fuzzy scale 1 x10 1 x10 0 x10 -1 FCS * s Header code Data code Decimal point Terminator Response @ x161 Unit x16 0 W k End code x16 1 x16 0 FCS * s Header code Terminator Communications Example In this example, the E5ZE is operated with Fuzzy Scale 1 Write (Wk) under the following conditions. Unit no. : 1 Memory bank no. : 2 Control point: 3 Fuzzy scale 1: 40. 0°C Command @ 0 1 W k 2 3 0 0 0 4 0 0 7 8 * s 40. 0°C Response @ 0 1 W k 0 0 7 D * s Normal end 7-4 Fuzzy Scale 1 Read: Rk This command is used to read the fuzzy scale 1 values that have been set at a control point. Function Command @ Unit x16 1 x160 Header code R k Bank Control point 0 0 FCS * s Data code Terminator 158 Fuzzy Scale 2 Write: Wl Response Read data Section 7-5 @ Unit x16 1 x160 R k End code x16 1 x16 0 x102 Fuzzy scale 1 x10 1 x10 0 x10 -1 FCS * s Header code Decimal point Terminator 1. The response block for Fuzzy Scale 1 Read (Rk) does not include read data if the end code of the response block is other than 00. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5ZE-8

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5ZE-8 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag