User manual OMRON F250-UME

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON F250-UME. We hope that this OMRON F250-UME user guide will be useful to you.

Lastmanuals help download the user guide OMRON F250-UME.


Mode d'emploi OMRON F250-UME
Download
Manual abstract: user guide OMRON F250-UME

Detailed instructions for use are in the User's Guide.

[. . . ] 8hIa $"@ ! )80( $SSOLFDWLRQ 6RIWZDUH 23(5$7, 21 0$18$/ Front Matter Contents About this Manual Basic Operating Procedures Processing Items Setting Procedures Monitor Mode and Run Mode Other Functions System Settings Communicating with External Devices Appendices Revision History )80( $SSOLFDWLRQ 6RIWZDUH 2SHUDWLRQ 0DQXDO 5HYLVHG 'HFHPEHU iii Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. !DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. !WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. !Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. OMRON Product References All OMRON products are capitalized in this manual. [. . . ] There are two types of judgement conditions: Common judgement and individual judgement. In normal circumstances, adjust the common judgement conditions. Set the individual judgement conditions to perform strict or lenient judgement for a particular character. Common Judgement Conditions Use this function to set common judgement conditions for all models. Common judgement OK value (OK if at or above this value) Similarity level : [ 60] Differential level : [ 10] End Similarity level for 1st candidate (0 to 100 (60*)) Difference level between 1st and 2nd candidates (0 to 100 (10*)) 1. Select Judgement conditions. 1. QUEST OCV Measurement image Extract conditions Character conditions Measurement conditions 2 KB-6576 Select region Judgement conditions 7 0 1 . 0 Refer string The screen for selecting common or individual judgement will be displayed. Common judgement Individual judgement 2. Select Common judgement. The Common Judgement Settings Screen will be displayed. Common judgement Similarity level : [ 60] Differential level : [ 10] End 3. The settings will be registered and the screen in (1. ) will return. 2-21-(30) QUEST Character Verification Individual Judgement Conditions Use this function to set the similarity level for each model. Section 2-21 Use individual judgement to perform particularly strict or lenient inspections of a particular character. Individual judgement 0: [ -1] 1: [ -1] 2: [ -1] 3: [ -1] 4: [ -1] 5: [ -1] 6: [ -1] 7: [ -1] End Target character (0 to 9, A to Z, colon (:), forward slash (/)) Similarity level for OK result for 1st candidate (-1*, 0 to 100) -1: Judged based on common judgement conditions. 1. Select Judgement conditions. 1. QUEST OCV Measurement image Extract conditions Character conditions Measurement conditions 2 KB-6576 Select region Judgement conditions 7 0 1 . 0 Refer string The common and individual judgement selections will be displayed. Common judgement Individual judgement 2. Select Individual judgement. The Individual Judgement Settings Screen will be displayed. Individual judgement 0: [ -1] 1: [ -1] 2: [ -1] 3: [ -1] 4: [ -1] 5: [ -1] 6: [ -1] 7: [ -1] End 3. The settings will be registered and the screen in (1. ) will return. 2-21-(31) QUEST Character Verification Section 2-21 2-21-7 Checking Set Character Strings Use this function to check what characters have been set as the reference for verification. Select Refer string. 1. QUEST OCV Measurement image Extract conditions Character conditions Measurement conditions 2 KB-6576 Select region Judgement conditions 7 0 1 . 0 Refer string The characters strings set for each region will be displayed. Refer string Region0 : KB-65762 01. 11. 07 Region1: Region2 : Region3 : ESC:END 2. Press the ESC Key to close this screen. The screen in (1. ) will return. 2-21-(32) QUEST Character Verification Section 2-21 2-21-8 Measurement Screens Detailed measurement values can be displayed on the screen in Monitor and Run modes. These values are useful when adjusting measurement conditions. This section describes what kind of information can be displayed for QUEST character verification. SeeAlso CHECK Refer to 6(&7, 21 0RQLWRU 0RGH DQG 5XQ 0RGH for details on Monitor and Run modes. Press the SHIFT+ESC Keys on the Run Screen to access the following screen and change Display results to Details. 0. Scn 0 RUN NG 67ms Image status : Freeze(Before scroll) Display image :Image0 Image size : All Display results : Details End Image 0 Freeze Use the Up or Down Key to change to the unit for which QUEST character verification is set and the following detailed screens will be displayed. Use the SHIFT+Right or Left Keys to switch in order between the three screens. Measurement Regions The judgement result for this unit, the set regions, and the extraction frame for each character will be displayed. 0. Scn 0 RUN 1. QUEST OCV Judge : OK 0 OK 45ms 47 ms Judgement result for this unit KB - 6 5 7 6 2 0 1 . 0 7 Region The extraction frames will be displayed in dotted lines for automatic extraction mode. Region number 2-21-(33) QUEST Character Verification Section 2-21 Set Character Strings A list of character strings set as the reference for verification will be displayed. 0. Scn 0 RUN 1. QUEST OCV Region0: KB-65762 01. 11. 07 Region1: Region2: Region3: OK 45ms Characters displayed in OK color for OK result and displayed in NG color for NG result 2-21-(34) QUEST Character Verification Section 2-21 Measurement Values for Each Region The detailed measurement results for each region will be displayed. Press the SHIFT+ Right or Left Keys to display the following four screens in order: Similarity to set characters; similarity to 1st candidate; similarity to 2nd candidate; and density deviation. Similarity to set characters 1st line OK 45ms 0. Scn 0 RUN 1. QUEST OCV Region0 String KB-65???82 79 100 88 73 99 73 86 Set characters Similarity Set characters Similarity 2nd line . 11. 07 93 83 100 73 86 100 86 93 Similarity to 1st candidate OK 45ms 0. Scn 0 RUN 1. QUEST OCV Region0 1st candidate KB-65762 82 79 100 88 73 99 73 86 1st candidate Similarity 1st candidate Similarity . 11. 07 100 100 100 73 86 100 86 93 Similarity to 2nd candidate OK 45ms 0. Scn 0 RUN 1. QUEST OCV Region0 2nd candidate RD 02903 12 23 15 14 8 12 21 2nd candidate Similarity 2nd candidate Similarity . 0 0 77 11 12 . 61 13 23 2-21-(35) QUEST Character Verification Density deviation (Only sections with , _, and ?characters will be displayed. ) Section 2-21 OK 45ms 0. Scn 0 RUN 1. QUEST OCV Region0 Density deviation K B - 6 5? [. . . ] The higher the correlation value, the more similar the input image is to the model. Density images are the gray images of 256 gradations read by the Camera. Flow control is used to adjust the rate of data transfer. The receiving side notifies the sending side when it cannot keep up with the processing speed, causing the sending side to interrupt the transmission, and then the receiving side notifies the sending side when it wants the transmission to be restarted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F250-UME

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F250-UME will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag