User manual OMRON F3S-TGR-N R DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON F3S-TGR-N R. We hope that this OMRON F3S-TGR-N R user guide will be useful to you.

Lastmanuals help download the user guide OMRON F3S-TGR-N R.


Mode d'emploi OMRON F3S-TGR-N R
Download
Manual abstract: user guide OMRON F3S-TGR-N RDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Housing Material P: Plastic Housing M: Stainless Steel Housing 3: Contact configuration 20: 2 Normally Closed Contacts (NC) 21: 2 Normally Closed Contacts (NC) + 1 Normally Open Contact (NO) 4: Cable Length/connection for NLPR and NSMR 02: 2m Cable 05: 5m Cable 10: 10m Cable M1J8: M12 male connector, 8pin 4: Cable Length/connection for NMPR 02: 2m Cable, cable exit to the left 05: 5m Cable, cable exit to the left 10: 10m Cable, cable exit to the left M1J8: M12 male connector, 8-pin, cable exit to the left F3S-TGR-N@R 1 Ordering Information Elongated Sensors Type F3S-TGR-NLPR-20-02 F3S-TGR-NLPR-20-05 * F3S-TGR-NLPR-20-10 F3S-TGR-NLPR-20-M1J8 F3S-TGR-NLPR-21-02 F3S-TGR-NLPR-21-05 * F3S-TGR-NLPR-21-10 F3S-TGR-NLPR-21-M1J8 Cable Connection 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin Contact Configuration 2NC 2NC 2NC 2NC 2NC/1NO 2NC/1NO 2NC/1NO 2NC/1NO *. Preferred stock items. Small Sensor Type F3S-TGR-NSMR-20-02 F3S-TGR-NSMR-20-05 * F3S-TGR-NSMR-20-10 F3S-TGR-NSMR-20-M1J8 F3S-TGR-NSMR-21-02 F3S-TGR-NSMR-21-05 * F3S-TGR-NSMR-21-10 F3S-TGR-NSMR-21-M1J8 Cable Connection 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin Contact Configuration 2NC 2NC 2NC 2NC 2NC/1NO 2NC/1NO 2NC/1NO 2NC/1NO *. Preferred stock items. Miniature Sensor Type F3S-TGR-NMPR-20-02 F3S-TGR-NMPR-20-05 * F3S-TGR-NMPR-20-10 F3S-TGR-NMPR-20-M1J8 F3S-TGR-NMPR-21-02 F3S-TGR-NMPR-21-05 * F3S-TGR-NMPR-21-10 F3S-TGR-NMPR-21-M1J8 Cable Connection 2m pre-wired 5m pre-wired 10m pre-wired M12, 8pin 2m pre-wired 5m pre-wired 10m pre-wired M12, 8pin Contact Configuration 2NC 2NC 2NC 2NC 2NC/1NO 2NC/1NO 2NC/1NO 2NC/1NO *. [. . . ] EN954-1) Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact M +24V A1 GND A2 T31 Start KM1 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact G9SA-301 T22 T21 T12 T11 T32 Feedbackloop KM2 KM1 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue 13 NO contact 14 KM1 33 34 KM2 KM2 +Us GND M F3S-TGR-N@R 7 G9SB Single Sensor Application with G9SB-2002-C (up to Safety Category 4 acc. EN954-1) +24V A1 GND A2 T31 Start Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue Auxiliary output for indication (option) KM1 Feedbackloop G9SB-2002-C T22 T21 T12 T11 T32 KM2 KM1 13 14 KM1 23 24 KM2 KM2 +Us GND Series connection Application, up to 6 Sensors with G9SB-2002-C (up to safety Category 3 acc. EN954-1) Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact M +24V A1 GND A2 T31 Start KM1 Feedbackloop Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact G9SB-2002-C T22 T21 T12 T11 T32 KM2 KM1 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue 13 NO contact 14 KM1 23 24 KM2 KM2 +Us GND M 8 Safety Sensors / Components G9SX Single Sensor Application with G9SX-AD322-T15 (up to Safety Category 4 acc. EN954-1) +24V A1 T33 GND A2 T31 Start Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue Auxiliary output for indication (option) KM1 Feedbackloop G9SX-AD322 T22 T21 T12 T11 T32 KM2 KM1 S14 KM1 S24 KM2 KM2 M GND Series connection Application, up to 6 Sensors with G9SX-AD322-T15 (up to Safety Category 3 acc. EN954-1) Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact +24V A1 T33 GND A2 T31 Start KM1 Feedbackloop Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact G9SX-AD322 T22 T21 T12 T11 T32 KM2 KM1 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue S14 NO contact S24 KM2 KM2 KM1 M GND F3S-TGR-N@R 9 DeviceNet Safety NE1A and DST1-I/O-Terminals Single Sensor Application with NE1A and DST1-Safety-IO (up to safety Category 4 acc. EN954-1) +24V V0 GND G0 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue Auxiliary output for indication (option) Test 0 In 0 Test 1 In 1 NE1A-. . . DST1-MRD. . . Series connection Application, up to 6 Sensors with NE1A or DST1-Safety-IO (up to Safety Category 3 acc. EN954-1) Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact +24V V0 GND G0 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact Test 0 In 0 Test 1 In 1 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact NE1A-. . . DST1-MRD. . . Application with multiple Sensors with NE1A or DST1-Safety-IO (up to Safety Category 4 acc. EN954-1) Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact +24V V0 Test 0 Test 1 GND G0 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact Test 2 In 0 In 1 In 2 In 3 Switch 1: Test 0 In 0 Test 1 In 1 Switch 2: Test 0 In 2 Test 2 In 3 Switch 3: Test 1 In 4 Test 2 In 5 Magnetic Actuator F3S-TGR-NxxR Sensor yellow green black white red blue NO contact NE1A-. . . DST1-MRD. . . In 4 In 5 10 Safety Sensors / Components Safety Precautions !WARNING Be sure to turn OFF the power before performing wiring. Do not touch charge parts (e. g. , terminals) while power is ON. Do not allow the actuator to come close to the switch with the door open. Doing so may cause machinery to start operating and may result in injury. Keep actuators (magnets) away from magnetically sensitive equipment like PC harddisks, floppy disks etc. The magnetic field of the magnet will damage existing data. Mutual Interference If the switch and actuator are mounted in parallel, be sure to separate them by at least 25 mm, as shown below. 25 mm min. [. . . ] · Be sure to use the correct combination of switch and actuator. · Use a power supply of the specified voltage. Do not use power supplies with large ripples or power supplies that intermittently generate incorrect voltages. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3S-TGR-N R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3S-TGR-N R will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag