User manual OMRON F3S-TGR-SB DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON F3S-TGR-SB. We hope that this OMRON F3S-TGR-SB user guide will be useful to you.

Lastmanuals help download the user guide OMRON F3S-TGR-SB.


Mode d'emploi OMRON F3S-TGR-SB
Download
Manual abstract: user guide OMRON F3S-TGR-SBDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Safety sensor for Palletisers F3S-TGR-SB@C series Features For Palletiser F3S-TGR-SB@C series has been developed especially for Palletisers and wrapping machine access protection applications. 3 Different types available We provide 3 different Types as following: · 2 beam Type (beam pitch 500 mm) · 3 beam Type (beam pitch 400 mm) · 4 beam Type (beam pitch 300 mm) Active - Passive system and Plug and play By using a mirror system we can achieve an active - passive multi beam system. This active passive system will improve installation time and reduce costs. 500 mm 800 mm 900 mm Muting functions are integrated Following Muting functions are integrated: · Muting sensor inputs · Muting Lamp output · Override input (120 second max) · Test / Reset input · Interlock function and Test Reset input F3S-TGR-SB@C series G-49 F3S-TGR Decentralized Muting connection Box Furthermore, using a F39-TGR-SB-CMB1, it's possible to reduce the wiring time and wiring material for the muting Sensors and Muting Lamp etc. In the conventional solution all wires from the light curtain, mute sensors, lamp, reset are wired back to the mute controller in the control cabinet (See Ex. [. . . ] The Muting function may not work correctly because of this gap. To avoid the mutual interruption, we recommend to Use E3GT has ON delay timer internally (0 to 5 seconds) SOLUTION 2: Misalignment of pallets When using a CROSS MUTING system, It may cause that unexpected behavior when the pallets get out of alignment then E3GT also solves the problem by OFF delay timer (0 to 5 seconds). Object Gaps G-50 Safety Sensors / Components List of Models Safety Multi beam Sensors F3S-TGR-SB2-K@C Mirror Reflection Type (Type 2) Shape Number of optical axes 2 3 4 Sensing Distance Beam Pitch Model F3S-TGR-SB2-K2C-500(MTL)* F3S-TGR-SB2-K3C-800(MTL)* F3S-TGR-SB2-K4C-900(MTL)* 0. 5 to 6 m 500 0. 5 to 5 m 400 300 *. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. F3S-TGR-SB4-K2C-500MTL F3S-TGR-SB4-K@C Mirror Reflection Type (Type 4) Shape Number of optical axes 2 3 4 Sensing Distance Beam Pitch Model F3S-TGR-SB4-K2C-500(MTL)* F3S-TGR-SB4-K3C-800(MTL)* F3S-TGR-SB4-K4C-900(MTL)* 0. 5 to 6 m 500 0. 5 to 5 m 400 300 *. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. F3S-TGR-SB4-K2C-500MTL Muting Connecting Box (Order Separately) Flexible Connecting Box Appearance SLC Connection Type Other connection Model M12 8pin connector without cable 4 x Muting sensor connection (4pin) 1 x Muting Lamp M12 (4pin) 1 x Override/Test input M12 (4pin) 1 x cabinet connection M12 (8pin) M12 8pin connector with 100 mm cable F39-TGR-SB-CMB1 F39-TGR-SB-CMB2 Accessories (Order Separately) Connector Cable Appearance Cable length 2m 5m 10 m Specification Model F3S-TGR F39-TGR-SB4-CVLB2R M12 connector (8pin Socket) For cabinet connection F39-TGR-SB4-CVLB5R (From F3S-TGR-SB@-K@C or F3S-TGRSB-CMB@) F39-TGR-SB4-CVLB10R 2m M12 connector (4pin Plug) For Muting sensor, Muting Lamp connec- F39-TGR-SB4-CVLB2MC tion and Override/Test connection F3S-TGR-SB@C series G-51 Connector Plug Assemblies, Screw-on Type Appearance Cable connection direction Straight DC only 4pin Plug Right angle Screw-on 3 dia. (3 to 4 dia. ) XS2G-D4S6 Specification Connection method Applicable cable diameter Model XS2G-D4S5 Muting Lamp Appearance Specification Model 24 V DC F39-A11 Bulb for Maintenance Appearance Specification 24 V DC 3 W E14 Model F39-A11MB Laser alignment Kit Appearance F39-LKK2-SB Model G-52 Safety Sensors / Components Rating and Performance Safety sensors F3S-TGR-SB@-K@C Item Sensor type Applicable safety category Operating range Beam pitch and Number of beam Model F3S-TGR-SB4-K@C-@(MTL)* Type 4 Type 2 4, 3, 2, 1, B 2, 1, B F3S-TGR-SB@-K2C 0. 5 - 6 m F3S-TGR-SB@-K3C/K4C 0. 5 - 6 m F3S-TGR-SB@-K2C 500 mm 2 beam with mirror F3S-TGR-SB@-K3C 400 mm 3 beam with mirror F3S-TGR-SB@-K4C 300 mm 4 beam with mirror F3S-TGR-SB@-K2C 500 mm F3S-TGR-SB@-K3C 800 mm F3S-TGR-SB@-K4C 900 mm Within ±2. 5° Within ±5° Infrared LED (880 nm) 24 VDC ± 20% 420 mA Two PNP transistor outputs, 250 mA each. (500 mA sum) Light - ON Self-test (after power ON and during operation, one cycle during response time) Output short-circuit protection, Reverse Polarity protection ON to OFF 16ms max OFF to ON 300 ms (Maximum Power-ON time is 900 ms) Operating: -10 to +55 °C (with no dew condensation) 15% to 95% (non condensing) Yellow (RAL 1303 F14) IP65 M6 T-Bolt x 8, M6 Nut x 8 Mounting fixture x 4 EN61496-1; 1997 prEN61496-2; 1997 Outermost beam gap Effective aperture angle (EAA) Light source Power supply Current Consumption OSSD Output operation mode Test functions Protection Response time Ambient temperature Ambient humidity Metal housing (Al) painted Degree of protection Accessories Applicable standards *. If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. F3S-TGR-SB4-K2C-500MTL Muting Connecting Box F3S-TGR-SB-CMB@ Item Model F39-TGR-SB-CMB@ Power supply 24 VDC ± 20% Consumption 10 W max Ambient temperature During operation: -10 to +55 °C (with no dex condensation) Ambient humidity 15% to 95% (non condensing) RX connector M12 8 pins female Cabinet connector M12 8 pins male Sensor connector 4 x M12 4 pins female Muting indicator M12 4 pins female Test / Override connectors M12 4 pins female Metal housing (Al) painted Yellow (RAL 1303 F14) Degree of protection IP65 Material Case Aluminium Connector Brass with nickel plate Front Cover Aluminium Weight 0. 5 kg Accessories M6 T-Bolt x 4, M6 Nut x 4 Mounting fixture x 2, Connector cover x 2 F3S-TGR-SB@C series G-53 F3S-TGR Item Applicable standards Model F39-TGR-SB-CMB@ 93/68/EEC DIN V VDE 0801:1990 and am. A1:1994 EN 50081-2:1993 EN 55022:1998 Dimensions F3S-TGR-SB-K@C-@ with Mounting Brackets 47. 5 37. 7 A C, E 35 Model F3S-TGR-SB@-K2C500 F3S-TGR-SB@-K3C800 F3S-TGR-SB@-K4C900 13 73 A 614 mm 914 mm 1, 014 mm C 500 mm 800 mm 900 mm E 500 mm 400 mm 300 mm G-54 Safety Sensors / Components F39-TGR-SB-CMB1 Muting connection box Mounting bracket (Common bracket for F3S-TGR-SB@-K@C and F39-TGR-SB-CMB@ Connector Plug Assemblies, Screw-on Type XS2G-D4S5 M12 x 1 58. 7 20 dia. [. . . ] To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527. E19E-EN-01 In the interest of product improvement, specifications are subject to change without notice. G-58 Safety Sensors / Components [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3S-TGR-SB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3S-TGR-SB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag