User manual OMRON F3SP-U3P-TGR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON F3SP-U3P-TGR. We hope that this OMRON F3SP-U3P-TGR user guide will be useful to you.

Lastmanuals help download the user guide OMRON F3SP-U3P-TGR.


Mode d'emploi OMRON F3SP-U3P-TGR
Download

You may also download the following manuals related to this product:

   OMRON F3SP-U3P-TGR DATASHEET (884 ko)

Manual abstract: user guide OMRON F3SP-U3P-TGR

Detailed instructions for use are in the User's Guide.

[. . . ] E04E-EN-01 F3SP-U3P-TGR Series Single Beam Safety Control Unit Safety Level 2 USER´S MANUAL F3SP-U3P-TGR Cat. E04E-EN-01 User's manual F3SP-U3P-TGR series Single beam safety control unit, safety level 2, from 1 to 2 pairs of photocells E3FS USER'S MANUAL 1 F3SP-U3P-TGR User's manual The device conforms with the EC requirements in compliance with the following standards: -Low Voltage Directive 73/23/EEC -EMC Directive 89/336/EEC -Machinery Directive 89/392/EEC -IEC 61496-1: 1997 -IEC 61496-2 ed. 2 IEC 2001 (CDV draft 8) -DIN V VDE 0801: 1990 and -amendment A1: 1994 -EN 61000-4-2, -3, -4, -5, -6 -EN 55022: 1994 -DIN EN 60204-1: 1993 -EN 50178: 1998 -IEC 664-1: 1997 MANUFACTURER: TECHNO-GR s. r. l. via Torino, 13/15 10046 Poirino (TO) - ITALY Tel. +39 011 9452041 FAX +39 011 9452090 USER MANUAL: Version 3. 0 of 12/06/2003 3 F3SP-U3P-TGR User's manual INDEX 1 BEFORE USING THE DEVICE. [. . . ] contact of the muting sensor (photocell, proximity switch, other). contact of the muting sensor (photocell, proximity switch, other). Connect the photocells test input of transmitters TX1. Connect to the PNP output of the receivers RX1. Connect the photocells test input of transmitters TX2. Connect to the PNP output of the receivers RX2. contact. 11 F3SP-U3P-TGR 5-2 PIN OVERVIEW User's manual 12 F3SP-U3P-TGR 5-3 WIRING EXAMPLE. User's manual Connection of 2 safety PES to the control unit. GND MAIN SUPPLY 24 V DC Muting A-B TOP VIEW T E S T N. Align the photocells by observing the LEDs on the control unit: If the alignment of the relevant pair of photocell is correct, the corresponding LED will turn on. After the alignment, turn off the power supplying the control unit, close the TEST pushbutton and re-power the control unit again. Wait for the control unit to carry out the initial tests. At the end of this operation, the unit indicates the right alignment with the guard led green on. Carry out all the checks described in the final checks and in the routine maintenance operations. During aligning operations or normal working, check that the photocells connected to the same or other units do not interfere which each other, modifying their mutual position, for instance by positioning some pairs of transmitters on the other receiver side. NOTICE The control unit can detect the mutual interference between safety PESs. The control unit forces the output contact to open, when it detects external disturbance light including mutual interference light. The safety PESs should be installed the following way to avoid mutual interference. - The safety PESs are installed with sufficient distance. - Emitters and receivers of safety PES are installed alternately as follows: TX RX RX TX 15 F3SP-U3P-TGR User's manual 7 OPERATING PROCEDURES. 7-1 DIP-SWITCHES CONFIGURATION. The configuration indicated in the table must be selected on the dip-switch available in the front. 4 X 3 Off On not used Function muting A-B act on the sensor couples 1 and 2. Function muting 60 s muting s * Function manual restoring automatic restoring ON Function SW 1 4 3 2 1 2 Off On 1 Off On The control-unit is manufactured from the factory with the following configuration: · Automatic reset, all 2 sensors in muting, the maximum duration of the muting is of sixty seconds. * infinite muting duration: this feature must be used carefully because it's against the norm. Using this, the user must know that it works under its sole responsibility. 7-2 CONFIGURATION OF THE NUMBER OF PHOTOCELLS. [. . . ] · GREEN LED GUARD: if switched on, in green, the barrier is working regularly and there are no detected obstacles; in this condition, the safety outputs are closed. The F3SP-U3P-TGR has inside an easy diagnosis with the four green leds to detect the most common errors or failure that can be presents: · One led flashing: Probable error in a photocells pair. · Two leds flashing: Probable incorrect setting of numbers of beams connected. · Tree leds flashing: Probable fail in muting lamp connection. · Four leds flashing: Probable internal error. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3SP-U3P-TGR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3SP-U3P-TGR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag