User manual OMRON F3UV DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON F3UV. We hope that this OMRON F3UV user guide will be useful to you.

Lastmanuals help download the user guide OMRON F3UV.


Mode d'emploi OMRON F3UV
Download
Manual abstract: user guide OMRON F3UVDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Ultraviolet power monitor/illumination monitor F3UV F3UV Monitoring output state of UV (ultraviolet light)/illumination light source Features Optical Fiber Type Can be used as ultraviolet power monitor/illumination monitor During projection monitoring Fiber Units UV Power Monitor Heat resistance applications Head can resist heat up to 300°C (using F3UV-HM) Converts harmful ultraviolet light into visible light Case is made of ozone-proof and heatproof stainless steel (SUS303). UV light Visible light Light receiving element in the Amplifier does not deteriorates. Monitors projected light through fiber unit. Illumination light Illumination light F32-300, F32-70 F3UV-XW11/41, F3UV-XA F32-300, F32-70 F3UV-XW11/41, F3UV-XA F3UV A-215 Waterproof applications Head can resist heat up to 150°C (using F3UV-HM) Converts harmful ultraviolet light into visible light UV light Visible light Light receiving element in the Amplifier does not deteriorates. (Fiber unit not required) F3UV-XW11/41, F3UV-XA Application UV Cleaning: Detect liquid-crystal glass inside a UV cleaning chamber. Cleaning chamber UV lamp or UV spot light source Precision Parts Resin Hardening Process F3UV-HM F3UV-HM UV lamp UV Print Drying UV lamp UV resin F3UV-HM Liquid-crystal board F3UV-HM Fiber head F32-300 Fiber Spindle motor bearing F3UV-HM Roller Sheet F3UV-XW11 Dry Cleaning of Liquid Crystal Glass UV lamp Dicing process Adhesive tape UV lamp Chip Checking UV Light Deterioration in Food Processing UV Light UV Light Filling machine F3UV-A30 UV lamp Film Ring Roller F3UV-A30 Liquid crystal glass F3UV-A30 F3UV-A30 A-216 Standard Photoelectric Sensors Features Optical Fiber Type Built-in Amplifier Type (Cannot be used as illumination monitor) F3UV Amplifier Units F3UV-XW Series About 1/10th the cost The price is about 1/10th the price of a dedicated measuring instrument Digital % display for easy visualization of measured values 7-segment digital % display Easy teaching scheme Button teaching is possible for zero-point setting and sensitivity setting. Protective Structure to Prevent UV Deterioration. A zinc die-cast case and synthetic quartz glass for the light receiving window. Protective tubes and covers available as options. (Option) Quartz glass Wavelength conversion element Total reflection 1-5V UV light Visible light Photodiode Main circuit Output form can be selected. Two outputs: current/voltage output + decision output F3UV-XA Sensitivity control scheme Fine adjustment possible with 8-revolution dial. Aperture Verify output form with operation indicator lamp Illuminates at approximate range of 4 to 5 V Monitor UV Light Output Status with an Operation Indicator. (Lit at approx. 4 to 5 V. ) With control for sensitivity adjustment Filter Cover (reduced by 1/6. 5) Available. F3UV A-217 Ordering Information Built-in Amplifier Type Sensors Shape Intensity range of incident light 1 to 30 mW/cm 2 Output Analog voltage output (1 to 5 V) Model F3UV-A30 F3UV-A03 0. 2 to 3 mW/cm2 Accessories (Sold Separately) Shape Name Protective Tube (Protects the cord. ) Protective Cover (Protects the display. ) 1/6. 5 Filtering Cover Mounting Brackets Model F39-CU1M F39-HU2 F39-HU1 F39-L9 Optical Fiber Type Sensors Amplifier Unit Shape Connection method Output Evaluation output Answer-back output Current/voltage analog output Analog voltage output * A model with 5 times higher sensitivity is also available. Output form NPN output PNP output Model F3UV-XW11 * F3UV-XW41 Pre-wired --- F3UV-XA Head Unit (can only be used as UV power monitor) Shape *1 Wavelength range of incident light Max. [. . . ] (Perform the sensitivity setting after the temperature has stabilized. ) · Light Intensity Integral Mode Use the start setting at the start of illumination and the stop setting when completed. Teaching can be performed by pressing the buttons or with codes. (7) When changing the threshold value in light intensity monitor mode, set the processing mode switch to ADJ and adjust the threshold value. The judgement output will go ON if the light intensity is below the threshold value. The threshold value is set to 50 at the factory. (8) Set the processing mode switch to RUN to start measurement. In light intensity integral mode, start integration with the Reset input. For detailed operation procedures, see the product manual. F3UV-XA Sensitivity adjustment method During initial setup or when UV light source is replaced, adjust the control output to any value between 4 and 5 V using the sensitivity control. After that, you can monitor weakening of the UV light source intensity by monitoring the control output value. (Sensitivity adjustment) After installing and securing the sensor, adjust the sensitivity with the sensitivity control. When the control output value is within the range of 4 to 5 V, the orange operation indicator lamp illuminates. (The sensor output goes up to approximately 6 V, and thus the operation indicator lamp does not illuminate if the sensitivity is too high. ) Adjustment is easier if you verify that the operation indicator lamp is illuminated and then fine-adjust the sensitivity to the desired value while viewing the voltmeter display. (If the UV light intensity is too high) If the analog output is 5. 0 V or higher when the sensitivity control is set to MIN (all the way to the left), or if the analog output does not decrease when the sensor is moved away from the UV lamp, the UV light intensity exceeds the sensor specification. Move the sensor further away from the UV lamp (If the UV light intensity is too low) If the analog output is 5. 0 V or lower when the sensitivity control is set to MAX (all the way to the right), the UV light intensity is lower than the sensor specification. Move the sensor closer to the UV lamp. F3UV F3UV A-225 Precautions Important Be sure to observe the precautions listed here. These precautions are essential for safe operation. (1) Do not disassemble, repair, or modify this product. (3) Do not install the amplifier unit in a location where it will be (2) Do not short-circuit the two ends of the load. exposed to ultraviolet light. Correct Use F3UV general Wiring Considerations Connection (1) Ensure that the power supply voltage is below the maximum voltage before turning the power ON. (2) Ensure that the terminal polarity and wiring are correct. (3) Use a cable with 0. 3 mm2 or greater wires and which is no more than 5 m in length, and test operation before using. [. . . ] 2 3 cores conductor cross-sectional area: 0. 2mm ; insulation diameter: 1. 2mmStandard length: 2 m" Operation indicator (red) 9 Stability indicator (green) 12 Two, 2. 2 dia. 0. 5 59 4 8. 5 Mounting Holes 30 25 16. 4 0. 4 12. 5 2-M3 6 22. 5 13 16 37 6 3. 9 16 Two, 3. 2 dia. Mounting brackets (detachable) Stainless steel (SUS304) 3. 4 22. 5 2 16 Two, mounting holes Head Unit F3UV-HM dia. Toothed washer Two clamping nut Detection surface * M8 x 1 15 dia. 13. 2 17 39 15. 2 13 * Material: Stainless steel (SUS303) F3UV A-229 Head Unit F3UV-HT 5m ( 10 dia. ) Detecting element (perimeter) Fluoride resin Fluoride resin 2. 8-dia. flexible tube (stainless steel) 5 dia. 16. 8 17 68 2 32. 2 * C 7. 5 dia. (100 max. ) 5, 000 B 13 28 2. 2 dia. A * When using mounting bracket, please use within this dimensions. Note 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3UV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3UV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag