User manual OMRON G70A DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON G70A. We hope that this OMRON G70A user guide will be useful to you.

Lastmanuals help download the user guide OMRON G70A.


Mode d'emploi OMRON G70A
Download
Manual abstract: user guide OMRON G70ADATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] · I/O Block conforming to VDE 0160. Ordering Information List of Models Classification Output Input Internal I/O circuit common NPN (+ common) PNP (­ common) NPN/PNP 24 VDC 24 VDC 110 VDC max. , 240 VAC max. (See note) Rated voltage Model G70A-ZOC16-3 G70A-ZOC16-4 G70A-ZIM16-5 Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range. Suitable Relay/SSR Classification Output I/O Block Base NPN:G70A-ZOC16-3 PNP:G70A-ZOC16-4 G2R-1-S G2R-1-SN PCB Relay Solid State Relay G3R-OA202SZN G3R-OA202SLN G3R-ODX02SN G3R-OD201SN G3RZ-201SLN H3RN-1 H3RN-11 G3R-IAZR1SN G3R-IDZR1SN G3R-IDZR1SN-1 Input G70A-ZIM16-5 G2R-1A3-SN G2R-13-SN G2R-1A3-SND G2R-13-SND Note: G2R-13-SN has twin cross-bar contacts. Connecting Sockets for I/O Terminal Expansion Model P2RF-05-E P2RF-08-E Number of poles 1 pole (G2R: 1 pole usage) 2 poles (G2R: 2 poles usage) Accessories (Order Separately) G78-16-E Short Bar Applicable model G70A-ZOC16-3 G70A-ZOC16-4 G70A-ZIM16-5 Model G78-16-E I/O Block Base G70A 1 Specifications Ratings/Characteristics Item Contact resistance Permissible current Max. operating voltage Dielectric strength 10 A 380 VAC, 125 VDC 4, 000 VAC, 50/60 Hz for 1 min between connector and output terminals 2, 000 VAC, 50/60 Hz for 1 min between output terminals 250 VAC, 50/60 Hz for 1 min between connectors G70A-ZOC16-3 G70A-ZOC16-4 100 mA 30 VDC 4, 000 VAC, 50/60 Hz for 1 min between connector and input terminals 2, 000 VAC, 50/60 Hz for 1 min between coil terminals 250 VAC, 50/60 Hz for 1 min between connectors G70A-ZIM16-5 10 m (excluding the resistance of the relay to be used) Insulation resistance Vibration resistance Shock resistance Noise immunity Ambient temperature Ambient humidity Coil surge absorption element Protection diode for inverse connection Tightening torque Between connector and I/O terminals: 1, 000 M (at 500 V) Other: 100 M (at 500 V) Malfunction: 10 to 61. 2 to 10 Hz, 0. 1-mm single amplitude (0. 2-mm double amplitude); 61. 2 to 150 to 61. 2 Hz, 14. 7 m/s2 Malfunction: 200 m/s2 Noise level: 2. 0 kV; pulse width: 100 ns to 1 µs Operating: 0°C to 55°C (with no icing) Operating: 35% to 85% Diode: 1 A, 400 V Diode (2 A, withstand inverse voltage: 40 V) 0. 59 N·m Varistor (see note) Note: Use a DC relay with a built-in diode because a DC relay without a built-in diode does not absorb any coil surge. Relay (G2R-1-S, G2R-1-SN) Coil Ratings Rated voltage Rated current Coil resistance Coil inductance (H) (ref. [. . . ] LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be increased by approximately 1 mA; the VDC rated current, by approximately 4 mA. Operating characteristics are measured at a coil temperature of 23°C. Contact Ratings Refer to Ratings/Characteristics of G70A-ZIM16-5. SSR Ratings Input Module Input Model G3R-IAZR1SN G3R-IDZR1SN G3R-IDZR1SN-1 Rated voltage 100 to 240 VAC 5 VDC 12 to 24 VDC 5 VDC 12 to 24 VDC Operating voltage 60 to 264 VAC 4 to 6 VDC 6. 6 to 32 VDC 4 to 6 VDC 6. 6 to 32 VDC Input current 15 mA max. Must operate voltage Must release voltage 60 VAC max. 3. 6 VDC min. Output Model G3R-IAZR1SN G3R-IDZR1SN G3R-IDZR1SN-1 Logic level supply voltage 4 to 32 VDC Logic level supply current 0. 1 to 100 mA Output Module Input Model G3R-OA202SZN G3R-OA202SLN G3R-ODX02SN G3R-OD201SN Rated voltage 5 to 24 VDC Operating voltage 4 to 32 VDC Input current 15 mA max. Must operate voltage Must release voltage 4 VDC max. 1 VDC min. Output Model G3R-OA202SZN G3R-OA202SLN G3R-ODX02SN G3R-OD201SN 4 to 60 VDC 40 to 200 VDC 0. 01 to 2 A 0. 01 to 1. 5 A 8 A (10 ms) 8 A (10 ms) Load voltage 75 to 264 VAC Load current (see note) 0. 05 to 2 A Inrush current 30 A (60 Hz, 1 cycle) Note: The minimum current value is measured at 10°C min. I/O Block Base G70A 3 Characteristics Input Module Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards G3R-IAZR1SN 20 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0. 75-mm single amplitude (1. 5-mm double amplitude) 1, 000 m/s2 Operating: ­30°C to 80°C (with no icing) Storage: ­30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 10 Hz Ambient humidity Weight Output Module Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Approved standards G3R-OA202SZN G3R-OA202SLN G3R-ODX02SN G3R-OD201SN 1/2 of load power source 1 ms max. 1/2 of load power source cycle + 1 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0. 75-mm single amplitude (1. 5-mm double amplitude) 1, 000 m/s2 Operating: ­30°C to 80°C (with no icing) Storage: ­30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 100 Hz 2. 5 V max. Ambient humidity Weight Engineering Data When Mounted to a G2R Endurance Endurance (×104 operations) Switching current (A) 500 Maximum Switching Power G2R-1A-S (24 VDC) Note: AC resistive load 100 50 250 VAC resistive load 30 VDC resistive load 250 VAC inductive load (cos=0. 4) 10 5 DC resistive load DC inductive load (L/R=7ms) AC inductive load (cos=0. 4) The characteristics shown here are for 16-point mounting. [. . . ] OMRON S8VS Note: The above diagram shows the Unit mounted to a G2R-1-S. When mounting to a G3R-OA@ or G3RZ-201SLN, pins 11 to 14 are output terminals. When mounting to a G3R-OD@, pin 14 is a plus terminal and pin 11 is a minus terminal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G70A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G70A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag