User manual OMRON H3DS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H3DS. We hope that this OMRON H3DS user guide will be useful to you.

Lastmanuals help download the user guide OMRON H3DS.


Mode d'emploi OMRON H3DS
Download
Manual abstract: user guide OMRON H3DS

Detailed instructions for use are in the User's Guide.

[. . . ] Solid-state Timer Timers H3DS DIN Track Mounted, Standard 17. 5-mm Width Timer Range · A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC with H3DS-XL@) · Smart Dial/Selector-locking Mechanism: Prevents the dials and selectors on the Timer's front panel from being inadvertently operated or being operated without authorization. The lock can only be unlocked and locked with an optional pen-type Lock Key. · Screw-Less Clamp type available. [. . . ] The minimum applicable load is 10 mA at 5 VDC (failure level: P). Solid-state Twin Timer H3DS-F B-25 Connections Block Diagram ON indicator (Orange) OFF indicator (Green) ON/OFF start selector AC (DC) input Indicator circuit ROM RAM Clock Time scale selector Power supply circuit One-chip microcomputer Output circuit I/O Function Inputs Outputs Control output Flicker-ON start operation begins when inputs are turned ON. Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial. Terminal Arrangement H3DS-FLC A1 15 B1 A1 15 B1 H3DS-FL L 15 15 18 16 18 18 16 16 A2 18 16 A2 (See note 2. ) Note: 1. If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to flicker-ON start mode. If these terminals are disconnected, the mode switches to flicker-OFF start mode. DC supply voltage does not require the designation of polarity. B-26 Solid-state Twin Timer H3DS-F Operation Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time scale, or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting. Time Setting Use the ON/OFF-time setting dials to set the ON/OFF time. Locking/Unlocking of Selectors and Time Setting Dial The ON/OFF-time setting dials and time scale selectors can be locked using the Y92S-38 Lock Key, a special pen type tool that is sold separately. To lock the dials or selectors, insert the Lock Key in the keyhole to the lower right of the dial or selector and turn it clockwise until the dial or selector is completely covered with the red cover. To unlock, turn the Lock Key in the opposite direction. Settings for ON/OFF Start If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to flicker-ON start mode. If these terminals are disconnected, the mode switches to flicker-OFF start mode. The operating mode will not change if the state of the applied voltage changes during timer operation. Selection of Time Scale The time scale is selected by turning the ON-time scale selector and OFF-time scale selector. The time scales will appear in the following order in each time scale display window on the left of the selector: 0. 1 s, 1 h, 0. 1 h, 1 m, 1 s, 0. 1 h, 0. 1 m, 1 s. Note: The time scales "1 s" and "0. 1 h" appear twice. Both instances indicate exactly the same time scale. Key hole ON-time scale display window and selector OFF-time scale display window and selector Timing Charts Operating mode Flicker-OFF start (See note 1. ) Power (A1 and A2) Output relay: NO 15 and 18 (ON indicator) Output relay: NC 15 and 16 OFF indicator ON OFF ON OFF ON OFF ON OFF 0. 1 s min. Power (A1 and A2) Signal (B1 and A2) Output relay: NO 15 and 18 (ON indicator) Output relay: NC 15 and 16 OFF indicator ON OFF ON OFF ON OFF ON OFF ON OFF tON: ON set time tOFF: OFF set time Timing chart 0. 1 s min. Flicker-ON start (See note 1. ) tON: ON set time tOFF: OFF set time Note: 1. If voltage is applied to terminal B1, or if terminals A1 and B1 are shorted, the operating mode is switched to flicker-ON start mode. If these terminals are disconnected, the mode switches to flicker-OFF start mode. The reset time requires a minimum of 0. 1 s. When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Solid-state Twin Timer H3DS-F B-27 Timers Basic Operation Nomenclature H3DS-FL@ H3DS-FLC Wire connection holes Output ON/OFF indicator When the output is ON: Orange When the output is OFF: Green ON-time display window ON-time scale display window and selector (select one from 0. 1 s, 1 s, 0. 1 m, 1 m, 0. 1 h, and 1 h) OFF-time display window OFF-time scale display window and selector (select one from 0. 1 s, 1 s, 0. 1 m, 1 m, 0. 1 h, and 1 h) ON-time setting dial Lock for ON-time setting dial Lock for ON-time scale selector OFF-time setting dial Lock for OFF-time setting dial Lock for OFF-time scale selector Release holes 18 16 A2 (Front View) (Front View) Wire connection holes Attach the enclosed label here as a nameplate. (The label is attached to the Timer's DIN Track hook section at the time of shipment. ) B-28 Solid-state Twin Timer H3DS-F Dimensions H3DS-FL Surface color: Light gray 5Y7/1 (OMRON) 17. 5 73 45 80 44 68 H3DS-FLC Surface color: Light gray 5Y7/1 (OMRON) 17. 5 73 45 80 44 68 Solid-state Twin Timer H3DS-F B-29 Timers B-30 Solid-state Twin Timer H3DS-F Solid-state Star-delta Timer Timers Supply voltage Screw terminal type Star-delta operation 24 to 230 VAC (50/60 Hz)/24 to 48 VDC H3DS-GL Model Screw-Less Clamp type H3DS-GLC Y92S-38 50 cm (l) x 7. 3 mm (t) 1 m (l) x 7. 3 mm (t) 1 m (l) x 16 mm (t) End Plate Spacer PFP-50N PFP-100N PFP-100N2 PFP-M PEP-S H3DS-G · A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 1 second) Model Number Structure Model Number Legend H3DS -G L 123 1. [. . . ] Make sure that the voltage is applied within the specified range, otherwise the internal elements of the Timer may be damaged. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once or the Timer may not be reset or a timer error could result. Be sure that the capacity of the power supply is large enough, otherwise the Timer may not start due to inrush current (approx. 3 A) that may flow for an instant when the Timer is turned on. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3DS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3DS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag