User manual OMRON HL-5000 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON HL-5000. We hope that this OMRON HL-5000 user guide will be useful to you.

Lastmanuals help download the user guide OMRON HL-5000.


Mode d'emploi OMRON HL-5000
Download
Manual abstract: user guide OMRON HL-5000DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Lamp load has an inrush current of 10 times the steady-state current. Motor load has an inrush current of 6 times the steady-state current. Characteristics Degree of protection Life expectancy (see note 3) Operating speed Operating frequency Insulation resistance Contact resistance Dielectric strength IP65 Mechanical: 10, 000, 000 operations min. (under rated conditions) Electrical: See the following Electrical Life Expectancy. 5 mm/s to 0. 5 m/s (HL-5000) Mechanical: 120 operations/min Electrical: 30 operations/min 100 M min. [. . . ] All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. Roller Lever HL-5000 17. 5 dia. × 6. 6 (See note 1) (See note 2) Three, M5 x 12 M3 cover Allen-head clamping bolt screws Note: 1. The resin roller can be mounted anywhere in 360°. The head can be mounted in any of the four directions. Two, 5. 2+0. 2 dia. 0 mounting holes Rubber connector Adjustable Roller Lever HL-5030 17. 5 dia. × 6. 6 resin roller Adjustable up to 30R to 75R (See note) 65. 7±0. 8 60. 3±0. 8 51. 3±0. 8 39. 5±0. 8 32 16. 5 15. 5 M5 × 16 Allen-head bolt M5 × 12 Allen-head bolt 21. 4 21. 8 (82. 4) 60. 6 50±0. 2 4. 1 Note: The head can be mounted in any of the four directions. Dimensions not shown are the same as HL-5000. (19) Adjustable Rod Lever HL-5050 5. 4 3 dia. × 160 stainless steel rod 62. 8±0. 3 53. 4±0. 8 39. 5±0. 8 145 max. (See note) 32 16. 5 15. 5 M5 × 16 Allen-head bolt M5 × 12 Allen-head bolt 21. 4 21. 8 (82. 4) 60. 6 Note: 50±0. 2 4. 1 The head can be mounted in any of the four directions. Dimensions not shown are the same as HL-5000. (19) Sealed Plunger HL-5100 PT 8 dia. Stainless steel plunger 16. 5 Two, M3 head clamping screws OP 20. 2 50±0. 2 60. 6 Note: Dimensions not shown are the same as HL-5000. 4. 1 (19) 4 HL-5000 Sealed Roller Plunger HL-5200 12. 7 dia. × 4. 8 stainless steel roller Two, M3 head clamping screws (See note) 16. 5 HL-5000 PT OP 20. 2 50±0. 2 Three, M3 head 60. 6 Note: (19) The head can be mounted in either of the two directions. Dimensions not shown are the same as HL-5000. 4. 1 Coil Spring HL-5300 PT 30 (see note 2) Resin rod (See note 1) 6. 6 dia. 38±0. 2 110±2. 5 Two, M3 head clamping screws 16. 5 42±0. 2 20. 2 Note: 60. 6 50±0. 2 1. The coil spring may be operated from any directions except axial directions (). Be sure to use the dog or cam within 30 mm from the top end of the spring. (Avoid use within 80 mm from the mounting hole. ) 3. Dimensions not shown are the same as HL-5000. 4. 1 (19) Operation of Limit Switch Actuator Position Change (HL-5000, HL-5030, HL-5050) To change the angle of the actuator, loosen the Allen-head bolt on the side of the actuator lever. Then the actuator can be set at any angle. Head Direction Change (HL-5000, HL-5030) (HL-5050, HL5200) To change the head direction, loosen the two mounting screws. Then the head can be changed at 90° increments in one of four directions. HL-5000 HL-5030 Head mounting screw (Small white screw that can be turned with either a Phillips-head or flat-blade screwdriver) Head mounting screw (Black non-removable torque screw) Loosen the Allenhead bold Head mounting screw (Black non-removable torque screw) Head mounting screw (Small white screw that can be turned with either a Phillips head or flat-blade screwdriver) HL-5050 5 HL-5000 The head of the HL-5200 can be mounted in two directions only. [. . . ] The tightening torque applied to each bolt is 4. 90 to 5. 88 N S m {or 50 to 60 kgf S cm}. To mount the Limit Switch more securely, use two M5 screw holes on the rear panel and rear holes for positioning if the model is the HL-5jjjG-Series Limit Switches. Mounting holes Two, 5. 2-dia. holes (located diagonally for securing the rear side) Two, M5 screws or 5. 2-dia. holes (located diagonally for securing the front side) Only the HL-5jjjG has M5 x 0. 8 screw holes on the rear side. 6 HL-5000 Others · Do not use the Limit Switch outdoors, otherwise the Limit Switch will become damaged by rust or ozone. HL-5000 Correct Tightening Torque A loose screw may result in a malfunction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON HL-5000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON HL-5000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag