User manual OMRON JX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON JX. We hope that this OMRON JX user guide will be useful to you.

Lastmanuals help download the user guide OMRON JX.


Mode d'emploi OMRON JX
Download

You may also download the following manuals related to this product:

   OMRON JX MANUAL 2 (2253 ko)
   OMRON JX DATASHEET (957 ko)
   OMRON JX DATASHEET 1 (817 ko)
   OMRON JX QUICK GUIDE V1.0 (369 ko)

Manual abstract: user guide OMRON JX

Detailed instructions for use are in the User's Guide.

[. . . ] I558-E2-02-X JX Compact and complete Model: JX 200 V Class Three-Phase Input 0. 2 to 7. 5 kW 200 V Class Single-Phase Input 0. 2 to 2. 2 kW 400 V Class Three-Phase Input 0. 4 to 7. 5 kW USER'S MANUAL Introduction Introduction Thank you for choosing the general-purpose Inverter JX. This User's Manual (hereinafter called "this manual") describes the parameter setting methods required for installation/wiring and operation of the JX model, as well as troubleshooting and inspection methods. This manual should be delivered to the actual end user of the product. After reading this manual, keep it handy for future reference. [. . . ] A081 Function name AVR selection AVR voltage selection Data 00: Always ON 01: Always OFF 02: OFF during deceleration 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 d004, A001, A005 Default setting 02 Unit A082 200/400 4 Related parameters Functions ·With A081 (AVR selection), set whether to enable or disable this function. ·Note that the Inverter cannot output voltage beyond that of the incoming voltage. ·To avoid a possible overcurrent trip during deceleration, set the AVR selection to "Always ON" (A081: 00). Parameter No. Data 00 01 Description Always ON Always OFF OFF during deceleration Note Enabled during acceleration, constant speed operation, and deceleration. Disabled during acceleration, constant speed operation, and deceleration. Disabled only during deceleration in order to reduce the energy regenerated to the Inverter by increasing the motor loss. This will avoid a possible trip due to regeneration during deceleration. A081 02 Automatic Energy-saving Operation Function This function automatically adjusts the Inverter output power to a minimum during constant speed operation. This is suitable for the load of reduced torque characteristics, such as a fan and pump. Parameter No. A085 A086 Function name RUN mode selection Data 00: Normal operation 01: Energy-saving operation Default setting 00 50 Unit % Energy-saving response/ 0 to 100% accuracy adjustment ·To operate with this function, set the RUN mode selection (A085) to 01. You can adjust the response and accuracy in the energy-saving response/accuracy adjustment (A086). ·Controls the output power at a comparatively slow rate. If rapid load fluctuation like impact load occur the motor may stall resulting in an overcurrent trip. Parameter No. Data 0 A086 100 Fast Low Large Response Slow Accuracy High Energy-saving effect Small 4-26 4-2 Function Mode 2-step Acceleration/Deceleration Function This function changes the acceleration/deceleration time during such operations. Parameter No. A092 * Function name Acceleration time 2 2nd acceleration time 2 Deceleration time 2 2nd deceleration time 2 2-step acceleration/ deceleration selection 0. 01 to 99. 99 100. 0 to 999. 9 1000. to 3000. Data Default setting 15. 0 15. 0 15. 0 15. 0 00 Unit s s s s A292 A093 * A293 A094 * A294 A095 * A295 A096 * A296 00: Switched via multi-function input 09 (2CH) 01: Switched by setting 00: Switched via multi-function input 09 2nd 2-step acceleration/ (2CH) deceleration selection 01: Switched by setting 2-step acceleration 0. 0 to 400 frequency 2nd 2-step acceleration 0. 0 to 400 frequency 2-step deceleration 0. 0 to 400 frequency *2nd 2-step deceleration 0. 0 to 400 frequency Related parameters 4 00 0. 0 0. 0 0. 0 0. 0 Functions Hz Hz Hz Hz F002, F003, F202, F203, C001 to C005 * To switch to the 2nd control, allocate 08 (SET) to the multi-function input terminal and then turn it on. ·The acceleration/deceleration time can be switched via the multi-function input terminal or automatically with an arbitrary frequency. ·To switch via the multi-function input terminal, allocate 09 (2CH) to it. it Data 09 Symbol 2CH Function name 2-step acceleration/deceleration OFF Status ON Description Enables the 2-step acceleration/ deceleration time. Disables the 2-step acceleration/ deceleration time. Related parameters Required settings (Example 1) When A094/A294 is set to 00 FW C001 to C005 A094 = 00 (Example 2) When A094/A294 is set to 01 FW 2CH Acceleration 2 Deceleration 2 Acceleration 2 A095/A295 Deceleration 1 Acceleration 1 Deceleration 1 A096/A296 Deceleration 2 Acceleration 1 Output frequency Output frequency F002/F202 A092/A292 A093/A293 F003/F203 F002/F202 A092/A292 A093/A293 F003/F203 4-27 4-2 Function Mode Acceleration/Deceleration Pattern This function is used when smooth acceleration/deceleration is needed. Parameter No. A097 A098 Function name Acceleration pattern selection Deceleration pattern selection Data 00: Line 01: S-shape curve 00: Line 01: S-shape curve Default setting 00 00 Unit ·Acceleration/deceleration pattern can be set according to each system. 4 Parameter No. 00 Line Set value 01 S-shape curve Functions A097 (Acceleration) Output frequency Output frequency Time Time A098 (Deceleration) Output frequency Time Output frequency Time Description Accelerates/Decelerates linearly before reaching the set output frequency value. Helps prevent the collapse of cargo on the elevating machine or conveyor. External Frequency Adjustment Function (OI) Parameter No. A101 A102 A103 A104 A105 Function name OI start frequency OI end frequency OI start ratio OI end ratio OI start selection Related parameters 0. 00 to 400. 0 0. 00 to 400. 0 0. 00: External start selection 01: 0 Hz Data Default setting 0. 0 0. 0 0. [. . . ] 0. 0 to 200. 0 1. No C074 00 No C075 1 No C076 Communication error selection 02 No C077 C078 Various adjustment C081 Communication error timeout Communication wait time O adjustment 0. 00 0. 100. 0 No No Yes s ms % C082 OI adjustment 0. 0 to 200. 0 100. 0 Yes % * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. App-16 Appendix-1 Parameter List Parameter No. C086 C091 C101 Function name AM offset adjustment Not used UP/DWN selection Monitor or data range (Digital Operator) 0. 0 to 10. 0 Use "00". 00: Do not store the frequency data 01: Store the frequency data 00: Trip reset at power-on 01: Trip reset when the power is OFF 02: Enabled only during trip (Reset when the power is ON. ) 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) 03: OL (overload warning) 04: OD (excessive PID deviation) 05: AL (alarm output) 06: Dc (disconnection detected) 07: FBV (PID FB status output) 08: NDc (network error) 10: ODc (Do not use. ) 43: LOC (light load detection signal) 00: AND 01: OR 02: XOR 0. 0 to 100. 0 0. 0 to 100. 0 0. 0 to 100. 0 0. 0 to 100. 0 Default setting 0. 0 00 00 Changes during operation Yes No Unit Set value V C102 Reset selection 00 No C141 Logic operation function A input 00 No Others C142 Logic operation function B input 01 No C143 Logic operator selection Output terminal 11 ON delay Output terminal 11 OFF delay Relay output ON delay Relay output OFF delay Motor capacity selection *2nd motor capacity selection Motor pole number selection *2nd motor pole number selection Stabilization parameter *2nd stabilization parameter 00 No C144 C145 C148 C149 0. 0 0. 0 0. 0 0. 0 Factory default No No No No s s s s H003 Control parameter H203 200-V class 0. 2/0. 4/0. 75/1. 5/2. 2/3. 7/5. 5/7. 5 400-V class 0. 4/0. 75/1. 5/2. 2/3. 7/5. 5/7. 5 2 4 6 8 No Factory default 4 No 4 100 Yes Yes kW H004 H204 H006 H206 Pole % % 0. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON JX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON JX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag