User manual OMRON K3GN V1.03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON K3GN. We hope that this OMRON K3GN user guide will be useful to you.

Lastmanuals help download the user guide OMRON K3GN.


Mode d'emploi OMRON K3GN
Download

You may also download the following manuals related to this product:

   OMRON K3GN V1.04 (1968 ko)

Manual abstract: user guide OMRON K3GNV1.03

Detailed instructions for use are in the User's Guide.

[. . . ] 1/32 DIN Digital Panel Meter K3GN Compact and Intelligent Digital Panel Meter · A single Panel Meter covering a wide range of applications. 3 main applicable functions: · Process meter (DC voltage/current input). · RPM processor/tachometer (frequency input). · Digital data display for PC/PLC (RS-485 communications). [. . . ] When the remaining quantity of soup decreases to less than 20%, the K3GN lights the "Replenish" indicator. 24-VDC power supply* E4PA-LS50-M1 Ultrasonic Sensor OUT1 (Upper-limit alarm) K3GN OUT2 (Lower-limit alarm) 4 to 20 mA K3GN 100 % Volume of soup Replenish OUT 1 Large cup Medium cup K3FK CT Converter 20 % Small cup Note: *Power Supply: Recommended DC power supply: eg. OMRON S8VS. Monitoring Difference between Two Line Speeds The difference between the two line speeds is calculated by the PLC and the result is written via RS-485 to the K3GN where it is displayed. RS-485 communications output (calculation result) Monitoring Number of Motor Revolutions Power supply* Signal input 24-VDC power supply* Electromagnetic relay 4 to 20 mA K3GN (Set the input type to "Remote"). OUT1 (Upper limit) 0 to 1 A K3FK CT Converter K3GN-NDC OUT1 (Upper limit) E2E Proximity Sensor OUT2 (Lower limit) K3GN-NDC OUT2 (Lower limit) Position Indication on X-Y Table The position on the X-Y table is calculated by the PLC and the result is written via RS-485 to the K3GN where it is displayed. The scaling function can be used to display the result in millimeter units. PLC Note: *Power Supply: Recommended DC power supply: eg. OMRON S8VS. X RS-485 Communication output 135. 4 mm Y 00 mm K3GN (Set the input type to "Remote". ) X-Y Table K-18 1/32 DIN Digital Panel Meter K3GN Precautions !WARNING Do not touch any of the terminals while power is being supplied. Also, do not touch the terminals with a screwdriver while power is being supplied. Electrical shock may result via the screwdriver. Use a power supply meeting the power supply specifications of the K3GN. Be sure that the rated voltage is achieved within 2 s after turning ON the power. Use the K3GN within the specified temperature and humidity ranges. When installing the K3GN in a panel, be sure that the temperature around the K3GN (not the temperature around the panel) does not exceed 55°C. If the K3GN is subject to radiant heat, be sure that the temperature of the surface of the K3GN exposed to the radiant heat does not exceed 55°C by providing a fan or other heat removal method. Store the K3GN within the specified temperature and humidity ranges. Do not lay heavy objects on the product during use or storage. Doing so may deform or deteriorate the K3GN. after power is ON for correct measurement. !Caution Do not allow metal objects or conductive wire cuttings to enter the product. Doing so may result in electric shock, fire, or malfunction. !Caution Do not attempt to disassemble, repair, or alter the product. Doing so may result in electric shock, fire, or malfunction. !Caution Do not use the product where flammable or combustion gasses are present. Mounting Recommended panel thickness is 1 to 5 mm. Insert the K3GN in the square cutout, insert the adapter from the back, and push the K3GN into the cutout as far as possible. To make the K3GN waterproof, insert watertight packing in the K3GN. Install the watertight packing in the proper direction. Note that the packing is direction-sensitive. When gang-mounting two or more products in a cutout, be sure that the ambient temperature does not exceed the specifications. [. . . ] Bring the input value and display value within range. s. err (S. Err) (Flashes at 0. 5-s intervals) Not lit 99999 (Flashes at 0. 5-s intervals) -19999 (Flashes at 0. 5-s intervals) Not lit Not lit Greater than displayable range Less than displayable range 1/32 DIN Digital Panel Meter K3GN K-25 Panel indicators Additional Information Application as a Process Meter The initial settings required when using the K3GN a process meter are explained below using the following example. Setting Example Inputs in the range 1 to 5 V are scaled to the range 0 to 100. 0 kg and displayed. If the measurement value goes over 70. 0 kg, output 1 turns ON. If the measurement value goes below 50. 0 kg, output 2 turns ON. Initial Setting Procedure 1. If a measurement value is displayed (operation level), move to the initial setting level by holding down the Level Key for 3 s min. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K3GN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K3GN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag