User manual OMRON K3HB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON K3HB. We hope that this OMRON K3HB user guide will be useful to you.

Lastmanuals help download the user guide OMRON K3HB.


Mode d'emploi OMRON K3HB
Download

You may also download the following manuals related to this product:

   OMRON K3HB MANUAL 2 (2426 ko)
   OMRON K3HB DATASHEET (1331 ko)

Manual abstract: user guide OMRON K3HB

Detailed instructions for use are in the User's Guide.

[. . . ] Digital Indicators K3HB Series Distinct by Design, Distinguished in Performance K3HB-H K3HB-S K3HB-X K3HB-V Features Red-Green Display Allows Easy Recognition of Judgment Results · The measurement value display can be set to switch between red and green in accordance with the status of comparative outputs. This means that the status can be ascertained at a distance. Short Body with Depth of Only 95 mm (from Behind the Front Panel) · A short body of only 95 mm (see note) contributes to the development of slimmer and smaller control panels and installations. Position Meter Enables Easy Monitoring of Operating Status Trends · The present value with respect to the measurement or display range (full scale) can be viewed on a bar display. The operating status can be grasped intuitively, allowing easy judgement of levels and threshold values. HH H P L LL 27% shorter than earlier models Depth: 95 mm (See note. ) (The depth is 100 mm when mounted to the terminal cover. ) Note: Depth of DeviceNet models is 97 mm. Max Min B L T-ZR CMW Zero Hold TG T HH LL H L Position meter Select a Comparative Output Pattern to Suit the Discrimination or Control Application · The output pattern for comparative outputs can be selected. In addition to high/low comparison with set values, output based on level changes is also possible. [. . . ] 10, 000, Output error: ±0. 5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10, 000, Output error: ±0. 5% FS (1 V or less: ±0. 15 V; not output for 0 V or less) Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14. 2 mm (green/red); SV: 4. 9 mm (green) Scaling function, 2-input calculation function, measurement operation selection, averaging, previous average value comparison, forced-zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Display method Main functions Ambient operating temperature Ambient operating humidity Storage temperature Altitude Accessories -10 to 55°C (with no icing or condensation) 25% to 85% -25 to 65°C (with no icing or condensation) 2, 000 m max. Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5. 08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3. ) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. Linear Sensor Indicator K3HB-S 17 Characteristics Display range Sampling period Comparative out- One input put response times (transistor Two inputs outputs) Linear output re- One input sponse time Two inputs Insulation resistance Dielectric strength Noise immunity -19, 999 to 99, 999 One input: 0. 5 ms; Two inputs: 1. 0 ms OFF to ON: 1 ms max. , ON to OFF: 1. 5 ms max. OFF to ON: 2 ms max. , ON to OFF: 2. 5 ms max. (at 500 VDC) 2, 300 VAC for 1 min between external terminals and case 100 to 240 VAC models: ±1, 500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 µs/100 ns) 24 VAC/VDC models: ±1, 500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 µs/100 ns) Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions Approx. 300 g (Base Unit only) Conforms to NEMA 4X for indoor use (equivalent to IP66) IP20 IP00 + finger protection (VDE0106/100) EEPROM (non-volatile memory) Number of rewrites: 100, 000 UL61010C-1, CSA C22. 2 No. 1010. 1(evaluated by UL) EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II EN61326: 1997, A1: 1998, A2: 2001 EMI: EN61326+A1 industrial applications Electromagnetic radiation interference CISPR 11 Group 1, Class A: CISPRL16-1/-2 Terminal interference voltage CISPR 11 Group 1, Class A: CISPRL16-1/-2 EMS: EN61326+A1 industrial applications Electrostatic Discharge Immunity EN61000-4-2: 4 kV (contact), 8 kV (in air) Radiated Electromagnetic Field Immunity EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz) Electrical Fast Transient/Burst Immunity EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line) Surge Immunity EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted Disturbance Immunity EN61000-4-6: 3 V (0. 15 to 80 MHz) Voltage Dips and Interruptions Immunity EN61000-4-11: 0. 5 cycle, 0°/180°, 100% (rated voltage) Vibration resistance Shock resistance Weight Degree of protec- Front panel tion Rear case Terminals Memory protection Applicable standards EMC Input Ranges (Measurement Ranges and Accuracy) Input Input type Measurement range Indication range Input impedance 120 max. Accuracy (at 23±5°C) One input: ±0. 1% F. S. Maximum absolute rated input ±31 mA ±10 V K3HB-SSD DC voltage/current input 0 to 20 mA 4 to 20 mA 0 to 5 V 1 to 5 V ±5 V ±10 V 0. 000 to 20. 000 mA 4. 000 to 20. 000 mA 0. 000 to 5. 000 V 1. 000 to 5. 000 V ±5. 000 V ±10. 000 V -2. 000 to 22. 000 mA 2. 000 to 22. 000 mA -0. 500 to 5. 500 mA 0. 500 to 5. 500 V ± 5. 500 V ± 11. 000 V ±1 digit max. ±1 digit max. ±14. 5 V Note: The accuracy is for an ambient temperature of 23±5°C. 18 Linear Sensor Indicator K3HB-S Input type Connected terminals Input A Input B DC current range (mA) in-ta in-tb 24. 000 20. 000 16. 000 12. 000 8. 000 4. 000 0. 000 DC current input 0-20 E2 E1 E3 E3 Input type Connected terminals Input A Input B in-ta in-tb 0-5 DC voltage input 1-5 E4 E5 E3 E3 4-20 5 10 22. 000 22. 000 DC voltage range (V) 10. 000 5. 000 0. 000 5. 500 5. 500 0. 500 5. 500 11. 000 -5. 000 2. 000 -0. 500 -10. 000 -5. 500 -11. 000 -4. 000 -2. 000 The range shown in dark shading indicates the factory setting. Sampling and Comparative Output Response Times The K3HB-S sampling and comparative output response times depend on the calculation methods, timing hold type, and, for simple averaging, the averaging times. Refer to the following description for details. Output Refresh Period The K3HB-S repeats input reads, calculation, and judgement output processing. The output refresh period differs depending on whether there are one or two inputs, as outlined below. Output Response Time The comparative output response time is the sum of the data processing time and the output (relay or transistor) response time. One Input 0. 5 ms Input 0. 5 ms Input Output Input read Output refresh One Input 0. 5 ms 0. 5 ms Data processing time Input Output Input Output Input Output Input Output 0. 5 ms 0. 5 ms Input A or Input B R R R R Output response time (See note. ) Every 0. 5 ms Every 0. 5 ms Two Inputs 0. 5 ms 0. 5 ms 0. 5 ms 0. 5 ms Data processing time Two inputs 0. 5 ms Input 0. 5 ms Input 0. 5 ms Input Input Input Input Input R R R R R Output response time (See note. ) Input A or Input B Output Input read Output refresh Output Output Output Output Output Input A: Every 1 ms Input B: Every 1 ms Every 0. 5 ms Note: For transistor outputs: For one input: OFF to ON 1 ms and ON to OFF 1. 5 ms For two inputs: OFF to ON 2 ms and ON to OFF 2. 5 ms For relay outputs: The relay operation time of 15 ms is added to the transistor output response times. Linear Sensor Indicator K3HB-S 19 Common Specifications Event Input Ratings Input type Contact No-contact S-TMR, HOLD, RESET, ZERO, BANK1, BANK2, BANK4 ON: 1 k max. , OFF: 100 k min. TIMING Output Ratings Contact Output Item Resistive loads (250 VAC, cos=1; 30 VDC, L/R=0 ms) 5 A at 250 VAC 5 A at 30 VDC 5A Inductive loads (250 VAC, closed circuit, cos=0. 4; 30 VDC, L/R=7 ms) 1 A at 250 VAC 1 A at 30 VDC Transistor Output Maximum load voltage Maximum load current Leakage current 24 VDC 50 mA 100 µA max. Rated load Rated through current Mechanical life 5, 000, 000 operations expectancy Electrical life expectancy 100, 000 operations Linear Output Item Allowable load impedance Resolution Output error 0 to 20 mA 500 max. 10, 000 ±0. 5%FS 4 to 20 mA 0 to 5 V 5 k min. 1 to 5 V 0 to 10 V Serial Communications Output Item Synchronization method Baud rate Transmission code Data length Stop bit length Error detection Parity check RS-232C, RS-485 Start-stop synchronization 9, 600, 19, 200, or 38, 400 bps ASCII 7 bits or 8 bits 2 bits or 1 bit Vertical parity and FCS Odd, even Communications method Half duplex BCD Output I/O Ratings (Input Signal Logic: Negative) I/O signal name Inputs REQUEST HOLD MAX MIN RESET Item Input signal Input current for no-voltage input Rating No-voltage contact input 10 mA Signal ON voltage 1. 5 V max. Maximum load voltage Maximum load current Leakage current Maximum load voltage Maximum load current Leakage current 24 VDC 10 mA 100 µA max. 24 VDC 50 mA 100 µA max. Note: For details on serial and DeviceNet communications, refer to the Digital Indicator K3HB Communications User's Manual (Cat. No. [. . . ] Other measures for reducing noise include running lines along separate ducts and using shield lines. Example of Countermeasures for Inductive Noise on Input Lines + Signal input Digital Indicator 2 conductors with shield 4. If a noise filter is used for the power supply, check the voltage and current, and install the noise filter as close to the product as possible. Reception interference may occur if the product is used close to a radio, television, or wireless. Power supply input Line filter Signal input Digital Indicators K3HB-X/-V/-H/-S 31 Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K3HB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K3HB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag