User manual OMRON K3HB-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON K3HB-S. We hope that this OMRON K3HB-S user guide will be useful to you.

Lastmanuals help download the user guide OMRON K3HB-S.


Mode d'emploi OMRON K3HB-S
Download

You may also download the following manuals related to this product:

   OMRON K3HB-S DATASHEET (1383 ko)

Manual abstract: user guide OMRON K3HB-S

Detailed instructions for use are in the User's Guide.

[. . . ] N128-E1-01D K3HB-S/-X/-V/-H Digital Indicators USER'S MANUAL Preface Thank you for purchasing the K3HB. This manual describes the functions, performance, and application methods needed for optimum use of the K3HB. Please observe the following items when using the K3HB. · This product is designed for use by qualified personnel with a knowledge of electrical systems. · Read this manual carefully and make sure you understand it well to ensure that you are using the K3HB correctly. [. . . ] J Use the U [UP] and S [SHIFT] Keys to change the timing delay. · Units: ms for the K3HB-S, 100 ms for the K3HB-X/V/H K Press the M [MODE] Key to switch to the next parameter. L Press the L [LEVEL] Key for at least 1 s to return to RUN level. L 1 on-t 0000 US L 1 on-t 0020 M L 1 off-t 0 S L 1 off-t 0000 Functions and Operations US L 1 off-t 0010 M L 1 s min. L 1 z-lim off 123. 4 5-35 Section 5 Functions and Operations 5. 12 Eliminating Drift Near "0" Input adjustment level The zero limit function makes all measurement values "0" for inputs lower than a set value. Explanation of Functions Zero-limit If the input value is less than the set value, the measurement value becomes "0. " This function is effective to eliminate display drift and displacement near "0. " L1 z-lim (Z-LIM) Set the following parameter for zero-limit. The zero-limit value can be set only when zero-limit has been enabled. Parameter Zero-limit z-lim Zero-limit value lim-p Set value on/off 0 to 99 Meaning of set value on: Enabled off: Disabled 0 to 99 * L1 lim-p (LIM-P) * The decimal point depends on the "decimal point position" setting. Parameter Setting Procedure A Press the L [LEVEL] Key for at least 3 s in RUN level to move to the initial setting level. · "L 0" is displayed on the level/bank display to indicate the initial setting level. B Press the L [LEVEL] Key again once (less than 1 s) to move to the input adjustment level. · "L 1" is displayed on the level/bank display. C Press the M [MODE] Key several times to switch the PV display to "z-lim. " L 3 s min. L 0 Displays "L 0. " Functions and Operations L Less than 1 s L 1 tmg-h nomal Displays "L 1. " M S L 1 z-lim off D Press the S [SHIFT] Key to make the SV display flash. · The setting can be changed when the SV display starts to flash. E Use the U [UP] Key to change the set value to "on. " · Change the set value to "off" to disable the setting. F Press the M [MODE] Key to switch to the next parameter "lim-p. " · The set value is registered. L 1 z-lim off U L 1 z-lim on M L 1 lim-p 0 5-36 5. 12 Eliminating Drift Near "0" G Press the S [SHIFT] Key to make the SV display flash. · The setting can be changed when the SV display starts to flash. H Use the U [UP] and S [SHIFT] Key to change the zero-limit value. M L 1 lim-p 00 US L 1 lim-p 0010 I Press the M [MODE] Key to switch to the next parameter. · The set value is registered. M L 1 s min. L 1 step off J Press the L [LEVEL] Key for at least 1 s to return to RUN level. 1234. 5 Functions and Operations 5-37 Section 5 Functions and Operations 5. 13 Averaging Inputs Input adjustment level X V S H The averaging function smooths the displays and outputs for input values with dramatic fluctuations, such as spike noise. Explanation of Functions Average processing There are two types of averaging: "simple" and "moving. " Select one type. The number of samples ("averaging times") can also be specified for the input values to be averaged. Simple average is used when the display refresh period is to be lengthened. Moving average is used to remove periodic noise superimposed on input signals. [. . . ] The setting to be changed will flash. To next parameter. Appendices A-25 Appendices Sampling and Comparative Output Response Times The K3HB-S sampling and comparative output response times depend on the calculations, timing hold type, and, for simple averaging, the averaging times. Refer to the following description for details. Output Refresh Period The K3HB-S repeats input reads, calculation, and judgement output processing. The output refresh period differs depending on whether there are one or two inputs, as outlined below. One input 0. 5 ms Input Input A or Input B Output Input read Output refresh Output Output Output Output 0. 5 ms Input 0. 5 ms Input Input Input Input Every 0. 5 ms Every 0. 5 ms Two inputs 0. 5 ms Input Input A Input B Output Input read Output Output Output Output Output 0. 5 ms Input 0. 5 ms Input Input Input Input Input Input A: every 1 ms Input B: every 1 ms Output refresh Every 0. 5 ms Appendices A-26 Sampling and Comparative Output Response Times Output Response Time The comparative output response time is the sum of the data processing time and the output (relay or transistor) response time. One input 0. 5 ms 0. 5 ms 0. 5 ms Data processing time R R R R Output response time (See note 1. ) Two inputs 0. 5 ms 0. 5 ms 0. 5 ms 0. 5 ms Data processing time R R R R R Output response time (See note 1. ) (Note 1. ) For transistor outputs For one input: OFF ON 1 ms and ON OFF 1. 5 ms For two inputs: OFF ON 2 ms and ON OFF 2. 5 ms For relay outputs The relay operation time of 10 ms is added to the transistor output response times. Operation Timing Examples Example 1 The Unit operates as shown in the diagram to the right for the settings shown in the table below. Calculation Timing hold mode Averaging times (n) A Normal Once Output Output Output Output Output Output Comparative output response time 0. 5 ms + output response time (See note 1. ) 0. 5 Input 0. 5 Input 0. 5 Input 0. 5 Input 0. 5 Input Input Example 2 The Unit operates as shown in the diagram to the right for the settings shown in the table below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K3HB-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K3HB-S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag