User manual OMRON K8AB-PH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON K8AB-PH. We hope that this OMRON K8AB-PH user guide will be useful to you.

Lastmanuals help download the user guide OMRON K8AB-PH.


Mode d'emploi OMRON K8AB-PH
Download
Manual abstract: user guide OMRON K8AB-PH

Detailed instructions for use are in the User's Guide.

[. . . ] (value when rated operating voltage changes quickly from 0% to 100%) (Relays are normally ON and turn OFF for phase sequence or loss phase errors. ) Automatic reset 45 to 65 Hz 100 k min. Power (PWR): Green LED, Relay output (RY): Yellow LED One SPDT relay (6 A at 250 VAC, resistive load) Phase sequence, phase loss operating time Resetting method Input frequency Input impedance Indicators Output relays 2 Phase-sequence Phase-loss Relay K8AB-PH Cat. N145-E1-01 Specifications Ambient operating temperature Storage temperature Ambient operating humidity Storage humidity Altitude Voltage fluctuation range Input frequency Output relays Resistive load Inductive load Minimum load -20 to 60°C (with no condensation or icing) -40 to 70°C (with no condensation or icing) 25% to 85% 25% to 85% 2, 000 m max. 85% to 110% of rated input voltage 50/60 Hz ±5 Hz (AC power supply) 6 A at 250 VAC (cos = 1) 6 A at 30 VDC (L/R = 0 ms) 1 A at 250 VAC (cos = 0. 4) 1 A at 30 VDC (L/R = 7 ms) 10 mA at 5 VDC Maximum contact voltage 250 VAC Maximum contact current 6 A AC Maximum switching capacity Mechanical life Electrical life Terminal screw tightening torque Crimp terminals Insulation resistance 1, 500 VA 10, 000, 000 operations Make: 50, 000 times, Break: 30, 000 times 1. 2 N·m Two solid wires of 2. 5 mm2, two crimp terminals of 1. 5 mm2 with insulation sleeves, can be tightened together 20 M (at 500 V) between charged terminals and exposed uncharged parts 20 M (at 500 V) between any charged terminals (i. e. , between input, output, and power supply terminals) Terminal section: IP20, Rear case: IP40 Munsell 5Y8/1 (ivory) ABS resin (self-extinguishing resin) UL94-V0 200 g Mounted to DIN Track or via M4 screws 22. 5 (W) x 90 (H) x 100 (D) mm Overvoltage Category III, Pollution Degree 2 EN60255-5/-6 EN60664-1 EMI: EN61326 Industrial applications Electromagnetic interference wave CISPR11 Group 1, Class A: CISPR16-1/-2 Terminal interference wave voltage CISPR11 Group 1, Class A: CISPR16-1/-2 EMS: EN61326 Industrial applications Electrostatic discharge EN61000-4-2: 8 kV (in air) Radiating radio-frequency electromagnetic field EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz) Burst EN61000-4-4: 1 kV (I/O signal line), 2 kV (power line) Surge EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted RF EN61000-4-6: 3 V (0. 15 to 80 MHz) Power frequency magnetic field immunity EN61000-4-8: 30 A/m Voltage dip/short interruptions EN61000-4-11: 0. 5 cycle, 0. 180° each, polarity 100% (rated voltage) Degree of protection Case color Case material Weight Mounting Dimensions Installation environment Application standards Safety standards EMC Cat. [. . . ] Make sure that no weight rests on the product after installation. 10. To enable an operator to turn off this product easily, install switches or circuit breakers that conform to relevant requirements of IEC60947-1 and IEC60947-3, and label them appropriately. Precautions for Correct Use For Proper Use 1. Do not use the product in the following locations. · Places subject to radiant heat from heat generating devices. · Places subject to vibrations or physical shocks. Make sure to use setting values appropriate for the controlled object. Failure to do so can cause unintended operation, and may result in accident or corruption of the product. Do not use thinner or similar solvent for cleaning. When discarding, properly dispose of the product as industrial waste. Only use this product within a board whose structure allows no possibility for fire to escape. About Installation 1. When wiring, use only recommended crimp terminals. Do not block areas around the product for proper dissipation of heat. (If you do not secure space for heat dissipation, life cycle of the product will be compromised. ) 3. To avoid electrical shocks, make sure that power is not supplied to the product while wiring. To avoid electrical shocks, make sure that power is not supplied to the product when performing DIP switch settings. Noise Countermeasures 1. Do not install the product near devices generating strong high frequency waves or surges. When using a noise filter, check the voltage and current and install it as close to the product as possible. In order to prevent inductive noise, wire the lines connected to the product separately from power lines carrying high voltages or currents. Do not wire in parallel with or on the same cable as power lines. Other measures for reducing noise include running lines along separate ducts and using shield lines. To avoid faulty operations, malfunctions, or failure, observe the following operating instructions. 1. When turning on the power, make sure to realize rated voltage within 1 second from the time of first supply of electricity. Make sure to use power supply for operations, inputs, and transformer with the appropriate capacity and rated burden. [. . . ] Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K8AB-PH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K8AB-PH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag