User manual OMRON K8AB-TH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON K8AB-TH. We hope that this OMRON K8AB-TH user guide will be useful to you.

Lastmanuals help download the user guide OMRON K8AB-TH.


Mode d'emploi OMRON K8AB-TH
Download

You may also download the following manuals related to this product:

   OMRON K8AB-TH BROCHURE (214 ko)

Manual abstract: user guide OMRON K8AB-TH

Detailed instructions for use are in the User's Guide.

[. . . ] · Reduce the number of models by using multi-input support for thermocouple or Pt100 sensor input. Selecting Functions and Modes · The following settings are provided: alarm mode (upper limit/lower limit), enable/disable latch, °C/°F, relay output non-fail safe/fail safe, setting protection. Terminal Wiring with Ferrules · Wire with 2 × 2. 5 mm2 solid wire or 2 × 1. 5 mm2 wiring ferrules. Model Number Structure Model Number Legend K8AB-TH1Setting Range 1: Low-temperature range (0 to 399°C: setting in increments of 1°C) 2: High-temperature range (0 to 1800°C max. : setting in increments of 10°C) 4. [. . . ] The protection function can be released by pressing the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the input to the external input terminal for at least 5 s. The power indicator will light while the protection is being reset. Dimensions Note: All units are in millimeters unless otherwise indicated. Temperature Monitoring Relay K8AB-TH Mounting Hole Dimensions Two, M4 screws or two, 4-dia screws 22. 5 100 5 102 90 5 Note: Pull out and use the hooks when mounting using screws. 6 Temperature Monitoring Relay K8AB-TH Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. Do not use the product where subject to flammable or explosive gas. Otherwise, minor injury from explosion may occasionally occur. Never disassemble, modify, or repair the product or touch any of the internal parts. Minor electric shock, fire, or malfunction may occasionally occur. Loose screws may occasionally result in fire. Tighten terminal screws to the specified torque of 0. 54 to 0. 55 N·m. Set the parameters for the Temperature Monitoring Relay so that they are appropriate for the system being monitored. If they are not appropriate, unexpected operation may occasionally result in equipment damage or accidents. Use the following procedure to make the Temperature Monitoring Relay settings. · Make settings for the Temperature Monitoring Relay so that they are appropriate for the system being monitored. 14. Approximately 30 minutes is required for the correct temperature to be detected after turning the power supply to the Temperature Monitoring Relay ON. Turn the power supply ON at least 30 minutes prior to actually starting monitoring. 15. To avoid inductive noise, keep the wiring for the Temperature Monitoring Relay's terminal block away from power cables carrying high voltages or large currents. Also, do not wire power lines together with or parallel to Temperature Monitoring Relay wiring. Using shielded cables and using separate conduits or ducts is recommended. 16. Attach a surge suppressor or noise filter to peripheral devices that generate noise (in particular, motors, transformers, solenoids, magnetic coils or other equipment that have an inductance component). When a noise filter is used at the power supply, first check the voltage or current, and attach the noise filter as close as possible to the Temperature Monitoring Relay. [. . . ] Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K8AB-TH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K8AB-TH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag