User manual OMRON LY DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON LY. We hope that this OMRON LY user guide will be useful to you.

Lastmanuals help download the user guide OMRON LY.


Mode d'emploi OMRON LY
Download
Manual abstract: user guide OMRON LYDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] For PTF08-E and PTF14A-E, see "Track Mounted Socket. " 2. PTF@A (-E) Sockets have met UL and CSA standards: UL 508/CSA C22. 2. Mounting Plates for Sockets Socket model PT08 PT08QN PT11 PT11QN PT14 PT14QN PYP-1 PTP-1-3 PTP-1 For 1 Socket ----PTP-10 For 10 Sockets --PTP-12 --For 12 Sockets For 18 Sockets PYP-18 ----- Socket-Hold-down Clip Pairings Relay type Poles Front-connecting Sockets Socket model Standard, bifurcated contacts oper- 1, 2 ation indicator, built-in diode 3 4 CR circuit 2 PTF08A-E, PTF08A PTF11A PTF14A-E, PTF14A PTF08A-E, PTF08A Y92H-3 Clip model PYC-A1 Back-connecting Sockets Socket model PT08(QN), PT08-0 PT11(QN), PT11-0 PT14(QN), PT14-0 PT08(QN), PT08-0 PYC-1 Clip model PYC-P Specifications Coil Ratings Single- and Double-pole Relays Rated voltage Rated current Coil resistance Coil inductance (reference value) Arm. OFF 12. 2 46 180 788 3, 750 4, 430 12, 950 18, 790 40 160 650 2, 600 11, 000 0. 04 H 0. 17 H 0. 69 H 3. 22 H 14. 54 H 19. 20 H 54. 75 H 83. 50 H 0. 16 H 0. 73 H 3. 20 H 10. 6 H 45. 6 H Arm. ON 0. 08 H 0. 33 H 1. 30 H 5. 66 H 24. 6 H 32. 1 H 94. 07 H 136. 40 H 0. 33 H 1. 37 H 5. 72 H 21. 0 H 86. 2 H 10% min. [. . . ] Performance characteristic data are measured at a coil temperatures of 23°C. AC coil resistance and impedance are provided as reference values (at 60 Hz). Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. General-purpose Relay LY A-33 Electromechanical Relays Contact Ratings Relay 1-pole Load Resistive load (cos = 1) 110 VAC 15 A 24 VDC 15 A 15 A 250 VAC 125 VDC 15 A Inductive load (cos=0. 4, L/R=7 ms) 110 VAC 10 A 24 VDC 7 A Single contact 2-, 3- or 4-pole Resistive load (cos = 1) 110 VAC 10 A 24 VDC 10 A 10 A 250 VAC 125 VDC 10 A Inductive load (cos=0. 4, L/R=7 ms) 110 VAC 7. 5 A 24 VDC 5 A Resistive load (cos = 1) 110 VAC 5A 24 VDC 5 A 7A 250 VAC 125 VDC 7A Bifurcated contacts 2-pole Inductive load (cos=0. 4, L/R=7 ms) 110 VAC 4 A 24 VDC 4A Rated load Rated carry current Max. switching power Failure rate (reference value)* 1, 700 VA 360 W 100 mA, 5 VDC 1, 100 VA 170 W 1, 100 VA 240 W 100 mA, 5 VDC 825 VA 120 W 550 VA 120 W 10 mA, 5 VDC 440 VA 100 W *Note: P level: 60 = 0. 1 x 10-6/operation, reference value Characteristics Item Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength Vibration resistance Shock resistance Endurance All except Relays with bifurcated contacts 50 m max. Mechanical: Electrical: 18, 000 operations/hr 1, 800 operations/hr (under rated load) Relays with bifurcated contacts 100 M min. (at 500 VDC) 1, 000 VAC, 50/60 Hz for 1 min between contacts of same polarity 2, 000 VAC, 50/60 Hz for 1 min between contacts of different polarity Destruction: Malfunction: Destruction: Malfunction: Mechanical: Electrical: 10 to 55 to 10 Hz, 0. 5 mm single amplitude (1. 0 mm double amplitude) 10 to 55 to 10 Hz, 0. 5 mm single amplitude (1. 0 mm double amplitude) 1, 000 m/s2 200 m/s2 AC: 50, 000, 000 operations min. (at 18, 000 operations/hr) DC: 1, 00, 000, 000 operations min. (at 18, 000 operations/hr) Single-, three-, and four-pole: 200, 000 operations min. (at 1, 800 operations/hr under rated load) Double-pole: 500, 000 operations min. (at 1, 800 operations/hr under rated load) Ambient temperature* Operating: Single- and double-pole standard, bifurcated-contact Relays: ­25°C to 55°C (with no icing) (­25°C to 70°C if carry current is 4 A or less) All other Relays: ­25°C to 40°C (with no icing) (­25°C to 55°C if carry current is 4 A or less) Operating: 5% to 85% Single- and double-pole: approx. 70 g Ambient humidity Weight Note: 1. The values given above are initial values. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element used. A-34 General-purpose Relay LY Endurance Under Real Loads (reference only) LY1 Rated voltage 100 VAC Load type AC motor AC lamp Conditions Operating frequency Electrical life 50, 000 operations 100, 000 operations 25, 000 operations 100, 000 operations 1, 500, 000 operations 800, 000 operations 400 W, 100 VAC single-phase with 35-A in- ON for 10 s, OFF for 50 s rush current, 7-A current flow 300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s 3-A current flow 500 W, 100 VAC with 78-A inrush current, 5-A current flow Capacitor (2, 000 µF) AC solenoid 24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 6 s rent flow 50 VA with 2. 5-A inrush current, 0. 25-A current flow 100 VA with 5-A inrush current, 0. 5-A current flow ON for 1 s, OFF for 2 s LY2 Rated voltage 100 VAC Load type AC motor AC lamp Capacitor (2, 000 µF) Conditions Operating frequency Electrical life 200, 000 operations 80, 000 operations 10, 000 operations 150, 000 operations ON for 1 s, OFF for 2 s 1, 000, 000 operations 500, 000 operations 200 W, 100 VAC single-phase with 25-A in- ON for 10 s, OFF for 50 s rush current, 5-A current flow 300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s 3-A current flow 24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s rent flow 24 VDC with 20-A inrush current, 1-A current flow AC solenoid 50 VA with 2. 5-A inrush current, 0. 25-A current flow 100 VA with 5-A inrush current, 0. 5-A current flow LY4 Rated voltage 100 VAC Load type AC motor Conditions 200 W, 200 VAC triple-phase with 5-A inrush current, 1-A current flow 750 W, 200 VAC triple-phase with 18-A inrush current, 3. 5 A current flow AC lamp Capacitor (2, 000 µF) 300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s 3-A current flow 24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s rent flow 24 VDC with 20-A inrush current, 1-A cur- ON for 1 s, OFF for 2 s rent flow AC solenoid 50 VA with 2. 5-A inrush current, 0. 25-A current flow 100 VA with 5-A inrush current, 0. 5-A current flow ON for 1 s, OFF for 2 s Operating frequency ON for 10 s, OFF for 50 s Electrical life 500, 000 operations 70, 000 operations 50, 000 operations 5, 000 operations 200, 000 operations 1, 000, 000 operations 500, 000 operations General-purpose Relay LY A-35 Electromechanical Relays Approved Standards UL 508 Recognitions (File No. of poles 1 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 15 A, 30 VDC (Resistive) 15 A, 240 VAC (General use) TV-5, 120 VAC 1/2 HP, 120 VAC 15 A, 28 VDC (Resistive) 15 A, 120 VAC (Resistive) 12 A, 240 VAC (General use) 1/2 HP, 120 VAC 10 A, 30 VDC (Resistive) 10 A, 240 VAC (General use) 1/3 HP, 240 VAC 6 x 103 25 x 103 6 x 103 25 x 103 6 x 103 Operations 2 3 and 4 CSA 22. 2 No. of poles 1 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 15 A, 30 VDC (Resistive) 15 A, 120 VAC (General use) 1/2 HP, 120 VAC TV-5, 120 VAC 15 A, 30 VDC (Resistive) 15 A, 120 VAC (Resistive) 1/2 HP, 120 VAC TV-3, 120 VAC 10 A, 30 VDC (Resistive) 10 A, 240 VAC (General use) 6 x 103 25 x 103 6 x 103 Operations 2 3 and 4 SEV Listings (File No. of poles 1 2 to 4 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 15 A, 24 VDC 15 A, 220 VAC 10 A, 24 VDC 10 A, 220 VAC 6 x 103 Operations TÜV (File No. of poles 1 to 4 Coil ratings 6 to 125 VDC 6 to 240 VAC Contact ratings LY1, LY1-FD 15 A, 110 VAC (cos=1) 10 A, 110 VAC (cos=0. 4) LY2, LY2-FD, LY3, LY3-FD, LY4, LY4-FD 10 A, 110 VAC (cos=1) 7. 5 A, 110 VAC (cos=0. 4) 100 x 103 Operations VDE Recognitions (No. of poles 1 Coil ratings 6, 12, 24, 50, 110, 220 VAC 6, 12, 24, 48, 110 VDC Contact ratings 10 A, 220 VAC (cos=1) 7 A, 220 VAC (cos=0. 4) 10 A, 28 VDC (L/R=0 ms) 7 A, 28 VDC (L/R=7 ms) 7 A, 220 VAC (cos=1) 4 A, 220 VAC (cos=0. 4) 7 A, 28 VDC (L/R=0 ms) 4 A, 28 VDC (L/R=7 ms) 200 x 103 Operations 2 LR Recognitions (No. [. . . ] The PTF@A (-E) can be track-mounted or screw-mounted. For the LY@-CR (CR circuit built-in type) model, this figure should be 88. PTF@A (-E) PT@ Sockets PTF08A-E PTF11A PTF14A-E PT08 PT11 PT14 PT08QN PT11QN PT14QN PT08-0 PT11-0 PT14-0 Mounting Plates for Back-connecting PYP-1 Two, 3. 4-dia. holes PTP-1-3 49 42±0. 1 7. 7 PTP-1 59 Four, 3. 4-dia. holes R5 PYP-18 21. 6 7. 7 42±0. 1 49 492 17 x 27. 4 = 465. 8±0. 6 4. 5 3. 4 R1. 7 72 elliptical holes 5. 1 42 49 42±0. 1 49 28 t=1. 6 R5 Four, 3. 4-dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON LY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON LY will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag