User manual OMRON MK-S DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON MK-S. We hope that this OMRON MK-S user guide will be useful to you.

Lastmanuals help download the user guide OMRON MK-S.


Mode d'emploi OMRON MK-S
Download

You may also download the following manuals related to this product:

   OMRON MK-S DATASHEET 2 (1750 ko)

Manual abstract: user guide OMRON MK-SDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] · Standard models are UL, CSA, SEV, DEMKO, NEMKO, SEMKO, TÜV (IEC), and VDE. · Conforming to CENELEC standards. Model Number Structure Model Number Legend Standard Models MK 1 2 3 4 5 6 1. Internal Connection Construction Blank: Standard 2 or 5: Non-standard connection (Refer to Terminal Arrangement/ Internal Connections) 4. [. . . ] This DC coil comes in two types: standard coil polarity and reversed coil polarity. Refer to Terminal Arrangement/Internal Connections. Example: MK2PN1-I 24 VDC Reverse polarity 3. Refer to Terminal Arrangement/Internal Connections for non-standard internal connection. The gold plating thickness depends on the request. Example: MK3P-I AP3 24 VAC Gold plating thickness: 3 µm Accessories (Order Separately) Item Track-mounted Socket Hold-down Clip 8-pin type 11-pin type Model PF083A-E PF113A-E PFC-A1 A-46 General-purpose Relay MK-I/-S Specifications Coil Ratings UL, CSA, DEMKO, NEMKO, SEMKO, SEV, TÜV Rated voltage AC (~) 6V 12 V 24 V 50 V 100 V 110 V 120 V 200 V 220 V 230 V 240 V DC (=) 6V 12 V 24 V 48 V 100 V 110 V Rated current 60 Hz 360 mA 180 mA 88. 0 mA 39. 0 mA 24. 8 mA 21. 0 mA 18. 0 mA 12. 1 mA 11. 0 mA 10. 5 mA 9. 2 mA 255 mA 126 mA 56 mA 29. 5 mA 14. 7 mA 15. 1 mA 50 Hz 404 mA 202 mA 98. 0 mA 46. 3 mA 28. 4 mA 24. 7 mA 20. 2 mA 14. 2 mA 12. 9 mA 12. 3 mA 10. 3 mA 3. 9 16. 9 62. 0 330 1, 010 1, 240 1, 520 4, 520 5, 130 6, 170 6, 450 23. 5 95 430 1, 630 6, 800 7, 300 15% min. 1. 5 W Coil resistance Must operate voltage Must release voltage Max. of rated 90% to110% of voltage voltage rated voltage VDE Rated voltage AC (~) 6V 12 V 24 V 50 V 100 V 110 V 120 V 200 V 220 V 230 V 240 V DC (=) 6V 12 V 24 V 48 V 100 V 110 V Rated current 50 Hz 380 mA 175 mA 91. 0 mA 42. 0 mA 24. 0 mA 21. 5 mA 20. 0 mA 11. 2 mA 10. 2 mA 9. 6 mA 9. 4 mA 225 mA 116 mA 56. 0 mA 29. 0 mA 13. 1 mA 12. 5 mA 60 Hz 325 mA 145 mA 76. 5 mA 36. 0 mA 20. 5 mA 18. 0 mA 17. 0 mA 9. 4 mA 8. 7 mA 8. 1 mA 7. 9 mA 4. 4 19. 0 70. 7 330 1, 150 1, 400 1, 600 5, 110 5, 800 6, 990 7, 400 26. 7 107 440 1, 660 7, 660 8, 720 15% min. 1. 3 W Coil resistance Must operate voltage Must release voltage Max. of rated 90% to110% of voltage voltage rated voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and ±15% for DC coil resistance. Performance characteristic data are measured at a coil temperature of 23°C. ~ indicates AC and = indicates DC (IEC417 publications). For 200 VDC applications, a 100-VDC Relay is supplied with a fixed 6. 8 k, 30 W resistor. Be sure to connect the resistor in series with the coil. For models with the LED indicator built in, add an LED current of approximately 0 through 5 mA to the rated current. General-purpose Relay MK-I/-S A-47 Electromechanical Relays Contact Ratings Load Contact mechanism Contact material Rated load Rated carry current Max. switching power Resistive load (cos = 1) Single Ag 10 A at 250 VAC 10A at 28 VDC 10 A 250 VAC, 250 VDC 10 A 2, 500 VA, 280 W 1, 750 VA 7 A at 250 VAC Inductive load (cos = 0. 4) Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength 50 m max. [. . . ] Use Y-shaped terminals. PF083A-E (Conforming to EN 50022) Terminal Arrangement Eight, M3. 5 x 7 sems 7 4 Two, M4 or two 4. 5-dia. 35. 4 33±0. 2 Mounting Holes 33 41 max. 3. 5 2 21 max. PF113A-E (Conforming to EN 50022) Eleven, M3. 5 x 7 sems 7 4 Two, M4 or two 4. 5-dia. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON MK-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON MK-S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag