User manual OMRON MY DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON MY. We hope that this OMRON MY user guide will be useful to you.

Lastmanuals help download the user guide OMRON MY.


Mode d'emploi OMRON MY
Download
Manual abstract: user guide OMRON MYDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 0. 9 W 0. 9 to 1. 1 VA (60 Hz) Must operate voltage 80% max. voltage Power consumption (approx. ) 1. 0 to 1. 2 VA (60 Hz) 50 Hz AC 6 V* 12 V 24 V 48/50 V* 110/120 V 220/240 V DC 6 V* 12 V 24 V 48 V* 100/110 V 214. 1 mA 106. 5 mA 53. 8 mA 24. 7/ 25. 7 mA 9. 9/10. 8 mA 4. 8/5. 3 mA 151 mA 75 mA 37. 7 mA 18. 8 mA 9. 0/9. 9 mA 60 Hz 183 mA 91 mA 46 mA 21. 1/ 22. 0 mA 8. 4/9. 2 mA 4. 2/4. 6 mA % of rated voltage 110% Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/­20% for rated currents and ±15% for DC coil resistance. Performance characteristic data are measured at a coil temperature of 23°C. [. . . ] of poles 2 4 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC Contact ratings 10 A, 250 VAC (cos=1) 10 A, 30 VDC (L/R=0 ms) 5 A, 250 VAC (cos=1) 5 A, 30 VDC (L/R=0 ms) 10 x 10 3 Operations 100 x 103 MY4Z AC; 50 x 103 UL508 Recognitions (File No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 30 VDC (General purpose) 10 A, 250 VAC (General purpose) 5 A, 250 VAC (General purpose) 5 A, 30 VDC (General purpose) 6 x 10 3 Operations CSA C22. 2 No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC 10 A, 30 VDC 10 A, 250 VAC 5 A, 250 VAC (Same polarity) 5 A, 30 VDC (Same polarity) Contact ratings 6 x 103 Operations IMQ (File No. of poles 2 4 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 10 A, 30 VDC 10 A, 250 VAC 5 A, 250 VAC 5 A, 30 VDC Contact ratings 10 x 103 100 x 103 MY4Z AC; 50 x 103 Operations LR Recognitions (File No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 250 VAC (Resistive) 2 A, 250 VAC (PF0. 4) 10 A, 30 VDC (Resistive) 2 A, 30 VDC (L/R=7 ms) 5 A, 250 VAC (Resistive) 0. 8 A, 250 VAC (PF0. 4) 5 A, 30 VDC (Resistive) 1. 5 A, 30 VDC (L/R=7 ms) 50 x 103 Operations 4 50 x 103 SEV Listings (File No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC 10 A, 250 VAC 10 A, 30 VDC 5 A, 250 VAC 5 A, 30 VDC Contact ratings 10 x 10 3 Operations 100 x 103 MY4Z AC; 50 x 103 4 General-purpose Relay MY New model Engineering Data Maximum Switching Power MY2 Switching current (A) MY4, MY4Z Switching current (A) AC resistive load AC inductive load (cos=0. 4) AC resistive load AC inductive load (cos=0. 4) DC resistive load DC resistive load DC inductive load (L/R=7 ms) DC inductive load (L/R=7 ms) Switching voltage (V) Switching voltage (V) Endurance MY2 (Resistive Loads) Endurance (x10 3 operations) 10000 5000 3000 1000 500 300 30 VDC 30 VDC 250 VAC MY2 (Inductive Loads) Endurance (x10 3operations) 10000 5000 3000 1000 500 300 250 VAC 30 VDC 30 VDC 250 VAC 100 50 30 10 250 VAC 100 50 30 10 Switching current (A) Switching current (A) MY4 (Resistive Loads) Endurance (x10 3 operations) 10000 5000 3000 1000 500 300 MY4 (Inductive Loads) Endurance (x10 3 operations) 10000 5000 3000 250 VAC 30 VDC 1000 500 300 30 VDC 30 VDC 30 VDC 250 VAC 100 100 50 30 10 250 VAC 50 30 10 250 VAC Switching current (A) Switching current (A) General-purpose Relay MY New model 5 MY4Z (Resistive Loads) Endurance (x10 3 operations) 10000 5000 3000 1000 500 300 30 VDC 100 50 30 10 30 VDC 250 VAC MY4Z (Inductive Loads) Endurance (x10 3operations) 10000 5000 3000 1000 500 300 30 VDC 30 VDC 100 50 30 10 250 VAC 250 VAC 250 VAC Switching Current (A) Switching Current (A) Technical and Environmental Properties 2-Pole model Tracking Resistance Environmental Protection Flammability Class Pollution Degree Creepage Distance Clearance Distance Contact Material 600 CTI (base) RT1 Base, Insulator, Spool Case, Indicator, Nameplate, Push Button 2 4. 0 mm 3. 0 mm Ag 1 3. 2 mm 3. 0 mm AgNi + Au 600 CTI (base) RT1 ul 94V-0 ul 94V-2 4-Pole model 6 General-purpose Relay MY New model Typical information for reference only The following data is provided as experimental and/or calculated data for reference only. These figures fall under the category of typical behaviour and the operation of individual relays will vary according to the exact operating conditions. Typical Operate / Release Times AC Type (operate / release time) DC Type (operate / release time) Load reduction Factor 1 2-Pole model 8 ms/8 ms 14 ms/4 ms 4-Pole model 10 ms/10 ms 14 ms/6 ms 0. 8 For AC inductive loads (such as solenoids, contactors coils, etc. ) the reduction factor corresponding to cos(p. f. ) (cosine of the power factor) is multiplied by the rated current in order to identify the maximum allowable current. This approximation is not valid for loads with high inrush currents such as electric motors or fluorescent lamps. Reduction factor 0. 6 0. 4 1 0. 8 0. 6 0. 4 0. 2 cos(p. f. ) Multiple Contact DC Switching Capacity Switching capacity of DC resistive load 100 Effect of temperature on coil voltages MY2/4 Operating range (DC and AC type) vs ambient temperature 2 1 10 1. 5 Switching Current (A) MY4 U/Un 2 1 1. 0 4 contacts 3 contacts 2 contacts in series MY2 1: Max coil voltage permitted. 2: Min pick-up voltage with coil at ambient temperature 0, 1 20 0. 5 40 60 80 100 120 140 160 180 200 220 0 10 20 30 40 50 60 70 80 Switching Voltage (Vdc) Ambient temperature (°C) This graph can be used to estimate the number of contacts that can be This graph shows the typical relationship between the maximum / miniused to switch DC resistive loads mum coil and pick-up voltage and ambient temperature General-purpose Relay MY New model 7 Dimensions Note: All units are in millimeters unless otherwise indicated. 2-Pole Models MY2N 2. 6 Eight, 1. 2 dia. × 2. 2 long holes 0. 5 28 max. 36 max. 6. 4 21. 5 max. 4-Pole Models MY4N 2. 6 Eight, 1. 2 dia. × 2. 2 long holes 0. 5 28 max. 36 max. 6. 4 21. 5 max. Models with Test Button MY2IN 2. 6 6. 3 8 Eight, 1. 2 dia. × 2. 2 long holes 28 max. 80. 5 5 14. 2 36 max. 21. 5 max. MY4IN 2. 6 6. 3 8 Fourteen, 1. 2 dia. × 2. 2 long holes 0. 5 28 max. 14. 2 80. 5 5 36 max. Dielectric withstand voltage 2, 000 VAC, 1 min Insulation resistance (see note 2) Less than 1, 000 M 10 General-purpose Relay MY New model s Dimensions Note: All units are in millimeters unless otherwise indicated. Socket Dimensions Terminal arrangement/ Internal connections (top view) 38. 2 max. 36. 5 max. Mounting holes PYF08S 23. 2 max. --- 85 max. (5. 3) PYF08A-E Two, 4. 2 x 5 mounting holes Two, M3, M4, or 4. 5-dia. holes Eight, M3 x 8 sems screws 72 max. (TOP VIEW) 23 max. 31 max. Note: Track mounting is also possible. [. . . ] holes PY14/PY14-Y1 (See note) Fourteen, 3 x 1. 2 elliptical holes 25. 5 max. 29. 5 max. 42 max. 20 max. 24 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14QN/ PY14QN-Y1 (See note) 29. 5 max. 41. 5 max. 42 max. 22 max. 24 max. Note: The PY14QN-Y1 includes sections indicated by dotted lines. PY14-02 25. 5 max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON MY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON MY will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag