User manual OMRON NE1A-SCPU02 07-2009

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON NE1A-SCPU02. We hope that this OMRON NE1A-SCPU02 user guide will be useful to you.

Lastmanuals help download the user guide OMRON NE1A-SCPU02.


Mode d'emploi OMRON NE1A-SCPU02
Download

You may also download the following manuals related to this product:

   OMRON NE1A-SCPU02 2006 (6083 ko)

Manual abstract: user guide OMRON NE1A-SCPU0207-2009

Detailed instructions for use are in the User's Guide.

[. . . ] Z906-E1-07 DeviceNet Safety NE1A Series: NE1A-SCPU01(-V1)(-EIP)/ -SCPU02(-EIP) Safety Network Controller OPERATION MANUAL NE1A Series Safety Network Controller: NE1A-SCPU01(-V1)(-EIP)/-SCPU02(-EIP) Operation Manual Revised July 2009 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. !WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. [. . . ] When the input condition to the Reset Set Flip-Flop function block is turned ON, that ON status is maintained (latched) in the function block and the ON output is maintained at the Output Enable signal. The ON status is maintained in the function block, so the Output Enable signal stays ON even if the input condition goes from ON to OFF. The signal maintained in the function block is turned OFF when the function block's RESET condition is turned ON. Fault Present Output Setting A Fault Present output can also be used in programming. To enable this output, select the Fault Present checkbox on the Out Point Tab Page of the function block properties dialog box. Error Handling and Error Resetting Error condition Input and Reset are active simultaneously. Behavior for error detection Output Enable Fault Present OFF ON (safety state) Resetting the error condition Make one of the signals inactive. Timing Table Input RESET Output Enable Fault Present 150 Command Reference: Logic Functions Section 8-4 8-4-7 Diagram Comparator Unit Ver. 1. 0 or Later Input1 Output Enable Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8 Output Enable Default Maximum Number of Inputs General Description This function can be used with unit version 1. 0 or later (including Controllers that support EtherNet/IP). The Comparator function block compares the specified input signals (up to 8 inputs) with the comparison data set in the Configurator, and turns ON the Output Enable signal when all of the input signals match the comparison data. The Output Enable signal will be turned OFF when the input signals no longer match the comparison data. From 1 to 8 inputs can be set for the input signals. Set Parameters Parameter Comparison Data Setting range Default setting 00000000 to 11111111 00000001 (Input 1 is ON. ) (Individual bits correspond to Input 1 to Input 8) Optional Input Settings The number of inputs can be increased on the In/Out Setting Tab Page in the function block property dialog box. Parameter Number of inputs Setting range 1 to 8 Default setting 1 151 Command Reference: Logic Functions Truth Table Section 8-4 Truth Table for Comparator Evaluation (CD = Comparison Data): Input signals to Comparator Output signals from Comparator Input 7 × Input 8 × Output Enable 0 Input 1 CD for Input 1 × Input 2 × Input 3 × Input 4 × Input 5 × Input 6 × CD for Input 2 × × × × × × × 0 × CD for Input 3 × × × × × × 0 × × × × × CD for Input 4 × × × × × 0 CD for Input 5 × × × × 0 × × × × × × × × × CD for Input 6 × × × 0 CD for Input 7 × × 0 × × × × × × = CD for Input 1 = CD for Input 2 = CD for Input 3 = CD for Input 4 = CD for Input 5 = CD for Input 6 = CD for Input 7 CD for Input 8 = CD for Input 8 0 1 0: OFF; 1: ON Note "= CD for Input n" indicates that the Comparator input signals are the same as the comparison data. " CD for Input n" indicates that the Comparator input signals are not the same as the comparison data. "×" indicates that the status is not applicable (the input signals and comparison data may or may not be the same). 152 Command Reference: Logic Functions Timing Chart Section 8-4 Output Enable 1 2 The horizontal broken lines in the above diagram represent the comparison data for each input. Output Enable turns ON when all of the input signals match the comparison data. Output Enable turns OFF when any of the input signals does not match the comparison data. 153 Command Reference: Function Blocks Section 8-5 8-5 8-5-1 Command Reference: Function Blocks Reset Diagram Reset Monitored Input Output Enable Default Maximum Number of Inputs General Description The Output Enable signal will turn ON if the Reset signal is correctly input while the input condition to the Reset function block is ON. This function block can be used to prevent the machine from automatically reset, e. g. , when the power to the NE1A-series Controller is turned ON, when the operating mode is changed (from IDLE Mode to RUN Mode), or when a signal from a safety input device turns ON. Conditions for Output Enable Turning ON · The Monitored Input and all enabled optional inputs must be ON. And the Reset signal must be input correctly. Conditions for Static Release Turning ON The Monitored Input and all enabled optional inputs must be ON. Conditions for Reset Required Indication Turning ON If the following condition is met, the Reset Required Indication will become a 1-Hz pulse output. · The Monitored Input and all enabled optional inputs must be ON. If the Reset Signal is set to Low-High-Low, the Reset Required Indication will turn ON when the next condition is met. · The Reset signal turns ON. Set Parameters The Reset Signal can be set in NE1A-series Controllers with unit version 1. 0 or later (including Controllers that support EtherNet/IP). Parameter Reset Signal Setting range · Low-High-Low · Rising Edge Unit Ver. 1. 0 or Later Default setting Low-High-Low 154 Command Reference: Function Blocks Section 8-5 Low-High-Low Monitored Input Reset Output Enable Rising Edge Monitored Input Reset Output Enable 350 ms min. Number of Inputs Setting The number of inputs can be increased on the In/Out Setting Tab Page in the function block property dialog box. Parameter Number of inputs Setting range 2 to 8 (Optional Input Settings) Default setting 2 Optional Output Settings The outputs shown below can be used in the program. [. . . ] Pages 88 and 92: Information added on error latch time setting. Page 103: Information changed on number of inputs and outputs setting. Page 103: Information changed on output points setting. Pages 113, 118, 121, 124, and 128: Information changed on optional output setting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NE1A-SCPU02

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON NE1A-SCPU02 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag