User manual OMRON NS5-SQ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON NS5-SQ. We hope that this OMRON NS5-SQ user guide will be useful to you.

Lastmanuals help download the user guide OMRON NS5-SQ.


Mode d'emploi OMRON NS5-SQ
Download

You may also download the following manuals related to this product:

   OMRON NS5-SQ SETUP MANUAL (7009 ko)
   OMRON NS5-SQ PROGRAMMING MANUAL (13107 ko)

Manual abstract: user guide OMRON NS5-SQ

Detailed instructions for use are in the User's Guide.

[. . . ] V098-E1-05 NS15-TX_, NS12-TS_, NS10-TV_, NS8-TV_, NS5-SQ_, NS5-TQ_, NS5-MQ_ Programmable Terminals Host Connection Manual: Host Link OPERATION MANUAL Introduction This manual describes the configuration and settings required for communicating with the host devices used by NS-series Programmable Terminals for Host Link communications. First familiarize yourself with the contents of the manuals related to NS-series Programmable Terminals (the NS-series Setup Manual, NS-series Programming Manual, and the CX-Designer online help), and then use this manual for Host Link communications. 1 1-1 Overview This section provides an overview of connecting an NS-V1/V2 PT to an OMRON Programmable Controller that supports Host Link communications. The NS-V1/V2 PT is connected 1:1 to the CPU Unit or a Host Link Unit of an OMRON PLC. Host Link communications are used to read and display or write the words and settings in the host PLC. [. . . ] In the following, the words allocated in the DM area and the settings are shown. Allocation DM area word Port 1 Port 2 Writing Value Settings D32000 D32001 D32002 D32003 D32010 D32011 D32012 D32013 8000 0000 0007 0000 0000 Host link mode, 2 stop bits, even parity, data length 7 bits Communications speed 9600 bps. 0 for host link 1-3-2 Connecting to an RS-422A/485 Port at the Host Compatible Host Units Some models and series of OMRON PLCs have the RS-422A type host link function built in. With the CS-series and CQM1H, the host link method can be used by installing a serial Communications Board. In addition, some C200HX/HG/HE(-Z)E devices have an integral CPU Unit that can be connected in the host link method by installing a Communications Board. With the CPM2A and CPM2C, an RS-422A type of 1:1 NT Link can be created through a CPM1-CIF11 RS-422A Adapter. 19 Check the model and series of the PLC and the type of the installed Board or Unit before making a connection. The PLC Units that provide an RS-422A Host Link interface and that can be connected to an NS-series PT port to which an RS-232C/RS422A Link Adaptor (NS-AL002) is connected are listed in the following table. PLC Series CPU Units with Built-in Host Link Function CS Series CPU Units Connectable with Host Link Units or Expansion Communications Board CS1G-CPU42/43/44/45-EV1 CS1H-CPU63/64/65/66/67-EV1 CS1G-CPU42H/43H/44H/45H CS1H-CPU63H/64H/65H/66H/ 67H Host Link Unit/ Communications Board CS1W-SCB41-V1 CJ Series CJ1G-CPU44/CPU45 CJ1G-CPU42H/43H/44H/45H CJ1H-CPU65H/66H/67H CJ1H-CPU65H/66H/67H-R CJ2H-CPU64/65/66/67/68(-EIP) CJ1M-CPU11/12/13/21/22/23 CJ2M-CPU11/12/13/14/15 /31/32/33/34/35 CP1H-XA40DR-A/XA40DT-D/XA 40DT1-D/X40DR-A/X40DT-D/X40 DT1-D/Y20DT-D CP1L-L14DR-A/L14DR-D/L14DTD/L14DT1-D/L20DR-A/L20DR-D/ L20DT-D/L20DT1-D/M30DR-A/M 30DR-D/M30DT-D/M30DT1-D/M4 0DR-A/M40DR-D/M40DT-D/M40 DT1-D CJ1W-SCU41-V1 CP1W-CIF11 C Series C1000H-CPU01-EV1 C2000H-CPU01-EV1 C200HS-CPU01/03/21/23/31/33-E C120-LK202-EV1 C200H-LK202-EV1 C200HE-CPU11/32/42-E C200HE-CPU11/32/42-ZE C200HG-CPU33/43/53/63-E C200HG-CPU33/43/53/63-ZE C200HX-CPU34/44/54/64-E C200HXCPU34/44/54/64/65/85-ZE C200HE-CPU32/42-E C200HE-CPU32/42-ZE C200HG-CPU33/43/53/63-E C200HG-CPU33/43/53/63-ZE C200HX-CPU34/44/54/64-E C200HXCPU34/44/54/64/65/85-ZE C1000H-CPU01-EV1 C2000H-CPU01-EV1 C1000H-CPU01-EV1 C1000HF-CPUA1-EV1 C2000H-CPU01-EV1 C500-LK203 C500-LK201-EV1 C200HW-COM03/06-EV1 20 PLC Series CPU Units with Built-in Host Link Function CPM1-10/20CDR-@+CPM1-CIF11 CPM1A-10/20/30/40CD@-@+CPM1-CIF11 CPM2A-30/40/60CD-@+CPM1-CIF11 (Peripheral port connection) CPM2C-10/20-@ (See note 1. ) CPU Units Connectable with Host Link Units or Expansion Communications Board Host Link Unit/ Communications Board C Series CQM1H-CPU51/61 CV Series (See note 2. ) CVM1 Series (See note 2. ) SRM1 CV500-CPU01-EV1 CV1000-CPU01-EV1 CV2000-CPU01-EV1 CVM1-CPU01-EV2 CVM1-CPU11-EV2 CVM1-CPU21-EV2 SRM1-C02-V2+CPM1-CIF11 CV500-CPU01-EV1 CV1000-CPU01-EV1 CV2000-CPU01-EV1 CVM1-CPU01-EV2 CVM1-CPU11-EV2 CVM1-CPU21-EV2 CQM1H-SCB41 CV500-LK201 CV500-LK201 Note 1: Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect. 2: CPU Units of CVM1/CV-series PLCs without the suffix -EV@ cannot be connected. The RS-485 interface (2-wire method) provided by NS-series PTs is for connecting to an OMRON Temperature Controller. Do not connect it to an NS-series PT or PLCs using RS-485. Settings at the Host When using the RS-422A type host link method, the settings shown below must be made at the host (depending on the unit, some of these settings may not be necessary, or settings not shown here may be necessary). Item Setting at Host I/O port Communications speed Transfer code Parity 1-to-1/1-to-N Command level Unit # RS-422A Set the same baud rate as set at the NS-series PT (See note 1. ) ASCII, 7 data bits, 2 stop bits Even 1-to-N (See note 2. ) Level 1, 2, 3 00 Note 1: Set the Host Link communications speed (baud rate) to 9600 bps or 19200 bps with the Communications Setting menu item in the CX-Designer and the System Menu for the NS-series PT. For details, refer to 1-4 Settings for Host Link. 2: The 1-to-N setting enables using a BCC (Block Check Character). It is not actually possible to connect more than one NS-series PT in a single Host Link. The setting methods for each type of unit are described in the following. 21 Connecting to a C Series Host Link Unit C200H/C200HS/C200HE(-Z)E/C200HG(-Z)E/C200HX(-Z)E Rack-mounted Type: C200H-LK202-V1 Setting the Front Switches Set each switch with a flat blade screwdriver so that the values or symbols in the setting value window agree with the following: · Unit # (SW1, SW2) Set these switches to 0. · Command level, parity, and transfer code (SW4) Set this switch to 2. · Communications speed (SW3) Set this switch to 5 to select 9600 bps. Set this switch to 6 to select 19200 bps. Setting the Rear Switches · Terminator setting (selector switch) Set this switch to ON. Terminator · 1-to-1/1-to-N protocol selection (selector switch) Set this switch to 1-to-N (OFF). 22 C1000H/C2000H Rack-mounted Type: C500-LK201-EV1 Setting the Front Switches · Mode selector (key switch) Set this to Host link. Setting the Rear Switches · I/O port selection (selector switch) Set this to RS-422A. I/O port Synchronization · Unit # (DIP SW1) Set SW1-1 to SW1-5 to OFF (0). Terminator · Synchronization (selector switch) Set this to Internal. 0V · Communications speed (DIP SW2-1 to SW2-4) Set these switches to 0010 to select 19200 bps. Set these switches to 1010 to select 9600 bps. (0: OFF 1: ON) · 1-to-1/1-to-N selection (DIP SW2-6) Set SW2-6 to OFF (0) (1-to-N). · Command level (DIP SW2-7, SW2-8) Set these switches to ON (1). (Levels 1, 2, and 3 are enabled. ) · CTS selection (selector switch) Set this always to 0 V (ON). · Terminator setting (selector switch) Set this switch to ON. 23 C1000H(F)/C2000H Rack-mounted Type: C500-LK203 Setting the Rear Switches · I/O port selection (selector switch) Set this to RS-422A. 5V supply I/O port · Unit #, parity, and transfer code (DIP SW1-1 to SW1-7) Set SW1-1 to SW1-7 to OFF (0). Synchronization · Synchronization (selector switch) Set this to Internal. Terminator 0V · Communications speed (DIP SW2-1 to SW2-4) Set these switches to 0010 to select 19, 200 bps. [. . . ] These settings are made from the NS-V1/V2 PT's System Menu. 32 (1) Press the Comm. Tab in the System Menu to display the Communications Setup Screen. Button in the System Menu to display the screen, and then press the and Screen Switching Buttons to display the screen for page (2/3). (2) Press the drop-down menu button and set Host Link as the communications method for serial port A or B. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NS5-SQ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON NS5-SQ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag