User manual OMRON PRT1-SCU11

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON PRT1-SCU11. We hope that this OMRON PRT1-SCU11 user guide will be useful to you.

Lastmanuals help download the user guide OMRON PRT1-SCU11.


Mode d'emploi OMRON PRT1-SCU11
Download

You may also download the following manuals related to this product:

   OMRON PRT1-SCU11 DATASHEET (64 ko)

Manual abstract: user guide OMRON PRT1-SCU11

Detailed instructions for use are in the User's Guide.

[. . . ] W01E-EN-02 PRT1-SCU11 PROFIBUS-DP Gateway to Host Link/Compoway-F OPERATION MANUAL PRT1-SCU11 PROFIBUS DP Gateway Operation Manual Revised September 19, 2005 iv Notice: OMRON products are manufactured for use by a trained operator and only for the purposes described in this manual. The following conventions are used to classify and explain the precautions in this manual. Always heed the information provided with them. Indicates information that, if not heeded, is likely to result in serious injury or loss of life. [. . . ] Description (1/2 W) E5ER E5AR 2 2 1 1 Use a 220 (1/2 W) terminator. RR+ Shield Note The E5AR/E5ER supports baud rates of 9. 6, 19. 2 and 38. 4 kbits/sec. Ensure that the PRT1-SCU11 baud rate setting (DIP-switch 1 and 2) is set to the correct setting. 26 Wiring the RS-422A / RS-485 Devices Section 2-3 2-3-6 Connection for R88A-MCW151-E Host Link Communications The R88A-MCW151-E uses Host link communications over 4-wire RS-422A. The figure below shows the connection between one PRT1-SCU11 and 1 to 15 R88A-MCW151-E units. PRT1-SCU11 Signal Pin RS422A R1 Interface R+ 2 FG SS+ Phoenix Connector Switch SW1: OFF Switch SW2: ON 3 4 5 R88A-MCW151-E unit Pin Signal RS422A 1 RDInterface 2 RD+ 3 4 5 FG SDSD+ RS-422A Port Connector DIP switch SW2 Pin 1 OFF Pin 2 OFF Pin 3 OFF R88A-MCW151-E unit Pin Signal RS422A 1 RDInterface 2 RD+ 3 4 5 FG SDSD+ RS-422A Port Connector DIP switch SW2 Pin 1 OFF Pin 2 OFF Pin 3 ON Note 1. If the PRT1-SCU11 is connected on one end of the transmission circuit, the termination resistor must be enabled on the Unit, by setting Switch 2 to ON. The R88A-MCW151-E connected at one end of the transmission circuit, must also have its termination resistor enabled, by setting Pin 3 of DIPswitch SW2 to ON. The R88A-MCW151-E supports baud rates of 9. 6, 19. 2 and 38. 4 kbits/sec. Ensure that the PRT1-SCU11 baud rate setting (DIP-switch 1 and 2) is set to the correct setting. 27 Wiring the RS-422A / RS-485 Devices Section 2-3 2-3-7 Connection for E5AK/E5EK K-Format Communication The E5AK/E5EK Intelligent Digital Controllers use the K-Format communications over either 4-wire RS-422A or 2-wire RS-485. Both are supported, through dedicated communication option units. Refer to the E5AK/E5EK User Manuals for more information on these dedicated communication units. RS-422A Connection to E5AK/E5EK The RS-422A connection can be either one-to-one or one-to-N. Up to 15 E5AK/E5EK units can be connected in a one-to-N system. The figure below shows the connection between one PRT1-SCU11 and 1 to 15 E5AK/E5EK Intelligent Digital Controller units. The table below shows the pin numbers used on the E5AK and E5EK units for connection of communication signals. Refer to the E5AK/E5EK User Manuals for more information on Wiring. PRT1-SCU11 RS-422 Interface RS-422 RR+ SS+ FG E5AK / E5EK (1) (See table below) RS-422 SDB SDA RDB RDA Terminator 220 , 1/2W SDB SDA RDB RDA E5AK / E5EK (15) (See table below) RS-422 RS-422A Signal SDB (Transmission line) SDA (Transmission line) RDB (Receiver line) RDA (Receiver line) E5AK Pin number 31 32 20 19 E5EK Pin number 21 22 20 19 RS-485 Connection to E5AK/E5EK The E5AK/E5EK Intelligent Digital Controllers can also communicate over RS-485, using the dedicated communication option for RS-485. Refer to the E5AK/E5EK User Manuals for more information on the RS-485 dedicated communication unit. The RS-485 connection can be either one-to-one or one-to-N. Up to 15 E5AK/ E5EK units can be connected in a one-to-N system. The figure below shows the connection between one PRT1-SCU11 and 1 to 15 E5AK/E5EK Intelligent Digital Controller units. Refer to the E5AK/E5EK User Manuals for more information on Wiring 28 Wiring the RS-422A / RS-485 Devices Section 2-3 PRT1-SCU11 RS-485 Interface RS-485 RR+ SS+ FG E5AK / E5EK (1) (See table below) RS-485 A (2) B (2) A (1) B (1) Terminator 220 , 1/2W E5AK / E5EK (15) (See table below) RS-485 A (2) B (2) A (1) B (1) RS-485 Signal A (2) B (2) A (1) B (1) E5AK Pin number 32 31 19 20 E5EK Pin number 22 21 19 20 Note The E5AK/E5EK supports baud rates of 9. 6, and 19. 2 kbits/sec. Ensure that the PRT1-SCU11 baud rate setting (DIP-switch 1 and 2) is set correctly. 2-3-8 Connection for F7 Inverter Memobus Communication The F7 Inverter use the Memobus communications over either 4-wire RS422A or 2-wire RS-485. RS-422A Connection to F7 Inverter The RS-422A connection can be either one-to-one or one-to-N. Up to 15 F7 Inverter units can be connected in a one-to-N system. The figure below shows the connection between one PRT1-SCU11 and 1 to 15 F7 Inverter units. [. . . ] Page 11: Added text and version table to Specifications section. Page 11: Changed `modules' to `units' Page 11: Changed I/O words to bytes. Page 12: Reformatted specification table, added new protocols. Page 19: Improved text of section 2-1-3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON PRT1-SCU11

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON PRT1-SCU11 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag