User manual OMRON R5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON R5. We hope that this OMRON R5 user guide will be useful to you.

Lastmanuals help download the user guide OMRON R5.


Mode d'emploi OMRON R5
Download
Manual abstract: user guide OMRON R5

Detailed instructions for use are in the User's Guide.

[. . . ] Please read this Instruction Manual thoroughly before using. ⷠPlease keep this Instruction Manual at hand for your future reference. Before Using this Monitor Correct Use of this Monitor How to Care for this Monitor What You should know about Blood Pressure . Please follow the instructions of your doctor. [. . . ] Measurement is over and blood pressure values and pulse are displayed. when the measurement is over , a mark flashes , and the cuff deflates automatically. Then a mark turns on and blood pressure and pulse rate are displayed simultaneously. * If a measurement cannot be made or the blood pressure values are displayed abnormally high (low), refer to Page 15. * If the Velcro tape comes off during the measurement, wrap the wrist cuff snugly as shown in Page 7 and measure again after fastening the Velcro tape. Blood pressure measurement is complete now. press the START/STOP button to turn off the power. To make another measurement, repeat the procedure in Step 1 above. * Even if you forget to turn off the power, the monitor will turn off automatically in approximately 2 minutes. The R5 Blood Pressure Monitor can record up to seven measurements. The measurement values can be recalled after completion of the measurement or even when the power is off. Each time the "M" button is pressed, the previous measurement values are displayed. When all the stored measurement results are displayed, the display of the present measurement result or the first measurement result will resume (if the memory is recalled when the power is off. ) * Immediately after completion of the measurement, the memory may not be called even by pressing the "M" button. In that case, leave the finger from the "M" button and press it again to call the memory. * You can recall up to seven measurements. After reading the blood pressure values and pulse rate stored in the monitor, press the START/STOP button to turn off the power. * Even if you forget to turn off the power, the monitor will turn off automatically in approximately 2 minutes. * The stored measurements will remain in the memory even when the batteries are removed for battery replacement. To delete the memory (Everything in the memory will be deleted. ) (1) Press the "M" button while the power is off to call the measured data. (2) Press the START/STOP button for more than 2 seconds while pressing the "M" button. [. . . ] * In some very rare cases, some error may be caused by the physical natures. : OMRON Automatic Wrist Blood Pressure Monitor Model : R5 Display : Digital display Measurement : Oscillometric method Measurement Range : Pressure; 0 to 280 mmHg Pulse rate; 40 to 180 beats/min Accuracy : Pressure; Within ±4 mmHg Pulse rate; Within ±5% of reading Inflation : Automatic inflation by pumping Deflation : Automatic rapid deflation Pressure Detection : Electrostatic capacity semiconductor pressure sensor Power supply : Two AAA batteries (LR03) Battery Life : Approximately 400 measurements when using alkaline batteries at the room temperature of 22°C and by using three times a day and inflating to 170 mmHg Operating Temperature : +10°C to +40°C, 30 to 85% RH and Humidity Storage temperature : -20°C to +60°C, 10 to 95% RH and humidity Measurable circumference of wrist : 135 to 215 mm Weight of Main Unit : Approximately 130 g (not including batteries) External Dimensions : 54 (W) x 68 (H) x 32. : Internal power supply appliance type B : Storage case, two AAA alkaline batteries, Instruction manual * Specifications may be changed without prior notice. What you should know about Blood Pressure Blood pressure values measured at home tend to be lower than those measured at the doctor's office. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON R5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON R5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag