User manual OMRON RX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON RX. We hope that this OMRON RX user guide will be useful to you.

Lastmanuals help download the user guide OMRON RX.


Mode d'emploi OMRON RX
Download

You may also download the following manuals related to this product:

   OMRON RX DATASHEET (1845 ko)
   OMRON RX DATASHEET 1 (1633 ko)
   OMRON RX DATASHEET 2 (2618 ko)

Manual abstract: user guide OMRON RX

Detailed instructions for use are in the User's Guide.

[. . . ] I560-E2-03-X RX Customised to your machine Model: RX 200 V Class Three-Phase Input 0. 4 to 55 kW 400 V Class Three-Phase Input 0. 4 to 132 kW USER'S MANUAL Introduction Introduction Thank you for choosing the general-purpose Inverter RX Series. This User's Manual (hereinafter called "this manual") describes the parameter setting methods required for installation/wiring and operation of the RX model, as well as troubleshooting and inspection methods. This manual should be delivered to the actual end user of the product. After reading this manual, keep it handy for future reference. [. . . ] A044, A244, A344 0. 00 Hz Unit 4 Functions ·Enabled when "21" (ZS) is allocated to any of multi-function output terminals 11 to 15 (C021 to C025) or the relay output terminal (C026). When "VC", "special VP", "free V/F", "sensorless vector control", or "0-Hz sensorless vector control" is selected as the control method, this function works for the Inverter's output frequency. When the control method is "sensor vector control", this function works for the motor rotation frequency. Alarm Code Output (AC0 to AC3) ·This function outputs a 3-bit or 4-bit code signal to indicate the cause of an Inverter trip. Parameter No. Function name 00: Disabled C062 Alarm code selection 01: 3-bit code 02: 4-bit code 00 Data Default setting Unit ·If "01" (3-bit) or "02" (4-bit) is selected in alarm code selection C062, multi-function output terminals 11 to 13, or 11 to 14, are forced to output an alarm code. The following table shows the output alarm codes. Multi-function output terminals 14 AC3 0 0 13 AC2 0 0 12 AC1 0 0 11 AC0 0 1 With 4-bit code selected Factor code Normal Normal Trip cause With 3-bit code selected Factor code Normal Trip cause Normal E01 to E03, Overcurrent protection E04 E05, E38 Overload protection Overload protection in a low speed range Overvoltage/Incoming overvoltage protection Undervoltage protection Momentary power interruption protection IGBT error Braking resistor overload protection E01 to E03, Overcurrent protection E04 E05 Overload protection Overvoltage/Incoming overvoltage protection Undervoltage protection Momentary power interruption protection IGBT error Other errors 0 0 1 0 0 0 0 0 0 0 1 1 1 1 1 0 0 1 1 1 0 1 0 1 E07, E15 E09 E16 E30 E06 E07, E15 E09 E16 E30 4-99 4-2 Function Mode Multi-function output terminals 14 AC3 1 1 1 1 1 1 1 1 13 AC2 0 0 0 1 1 1 1 1 12 AC1 0 0 1 0 0 0 1 1 11 AC0 0 1 0 0 1 1 0 1 With 4-bit code selected Factor code E08, E11 E23, E25 E10 E12, E13 E35, E36 E14 E20 E21 E24 E50 to E79 Trip cause EEPROM error, CPU error, GA communication error, Main circuit error CT error External trip, USP error, Thermistor error, Brake error Grounding protection Abnormal temperature due to the cooling fin's speed drop Abnormal temperature Input phase loss protection Network error, Options 1, 2 Errors 0 to 9 With 3-bit code selected Factor code Trip cause 4 Functions Output Signal Logic Operation ·This function performs output signal logic operations inside the Inverter. ·All output signals are operation targets. However, the logic operation outputs (LOG1 to LOG6) are not subject to operations. Parameter No. Function name Multi-function output terminal selection Data 33: LOG1 (Logic operation output [C142, C143, C144]) 34: LOG2 (Logic operation output 2 [C145, C146, C147]) 35: LOG3 (Logic operation output 3 [C148, C149, C150]) 36: LOG4 (Logic operation output 4 [C151, C152, C153]) 37: LOG5 (Logic operation output 5 [C154, C155, C156]) 38: LOG6 (Logic operation output 6 [C157, C158, C159]) Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 1. Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 2. 00: AND 01: OR 02: XOR Default setting Unit C021 to C025 05 C026 Relay output (AL2, AL1) function selection C142/C145/C148/ C151/C154/C157 C143/C146/C149/ C152/C155/C158 C144/C147/C150/ C153/C156/C159 Logic output signal selection 1 Logic output signal selection 2 Logic output signal operator selection 00 00 00 4-100 4-2 Function Mode ·You can select from three types of operators (AND, OR, and XOR). Output signal 1 Output signal 2 LOGx (AND) LOGx (OR) LOGx (XOR) 4 ·The setting parameters vary depending on the logic operation output selected. Refer to the following table to set the necessary parameters. Selected signal Operand 1 selection C142 C145 C148 C151 C154 C157 Operand 2 selection C143 C146 C149 C152 C155 C158 Operator selection C144 C147 C150 C153 C156 C159 Functions 33: Logic operation output 1 (LOG1) 34: Logic operation output 2 (LOG2) 35: Logic operation output 3 (LOG3) 36: Logic operation output 4 (LOG4) 37: Logic operation output 5 (LOG5) 38: Logic operation output 6 (LOG6) (Example) To output a logic output 1 (LOG1) signal through AND operation of "RUN signal" (00: RUN) and "over set frequency arrival signal" (02: FA2) to multi-function output 2 ·Multi-function input 2 selection (C002) : 33 (LOG1) ·Logic output signal 1 selection 1 (C142) : 00 (RUN) ·Logic output signal 1 selection 2 (C143) : 02 (FA2) ·Logic output signal 1 operator selection (C144): 00 (AND) Capacitor Life Warning Signal ·This function determines estimated service life of the capacitor on the PCB, based on the Inverter's internal temperature and ON time. ·Life assessment monitor d022 shows the status of this signal. ·If this function is activated, it is recommended that the main circuit board and logic board be replaced. Parameter No. C021 to C025 C026 Function name Multi-function output terminal selection Relay output (AL2, AL1) function selection Data 39: WAC (Capacitor life warning signal (on PCB)) Default setting 05 Unit 4-101 4-2 Function Mode Network Error ·Enabled only when ModBus-RTU is selected for RS485 communication. ·If a reception timeout error occurs, this signal is output until reception of the next data. ·Set a time before reception timeout in communication error timeout C077. ·For details, refer to "4-4 Communication Function". Parameter No. C021 to C025 C026 C077 Function name Multi-function output terminal selection Relay output (AL2, AL1) function selection Communication error timeout Data 32: NDc (network communication disconnection detection) 0. 00 to 99. 99: Set a time before reception timeout. Default setting 05 Unit 4 0. 00 s Functions External controller Inverter Monitor timer Communication trip time (C077) Communication disconnection detection signal (NDc) Cooling Fan Speed Drop Signal ·This signal is output when detecting that the Inverter's built-in cooling fan rotation speed is reduced to 75% or less. ·If "01" is selected in cooling fan control b092, this signal is not output even while the fan is stopped. ·While this signal is output, check the cooling fan for clogging. ·Life assessment monitor d022 shows the status of this signal. Parameter No. [. . . ] 4-137 SF1 to SF7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18 signal during RUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-96 sink logic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22 slide switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON RX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON RX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag