User manual OMRON SENSOR SUPPORT SOFTWARE S3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON SENSOR SUPPORT SOFTWARE S3. We hope that this OMRON SENSOR SUPPORT SOFTWARE S3 user guide will be useful to you.

Lastmanuals help download the user guide OMRON SENSOR SUPPORT SOFTWARE S3.


Mode d'emploi OMRON SENSOR SUPPORT SOFTWARE S3
Download
Manual abstract: user guide OMRON SENSOR SUPPORT SOFTWARE S3

Detailed instructions for use are in the User's Guide.

[. . . ] E31E-EN-01 SensorSupportSoftware S3 Software Description OPERATION MANUAL TABLE OF CONTENTS SECTION 1 General. . 1-1 1-2 1-3 1-4 1-5 1-6 1-7 Validity . . 5 6 6 6 7 7 7 8 SECTION 2 Safety notes. . 9 10 SECTION 3 Program installation . [. . . ] The teach buttons C and D are each activated when the Connector pin 2 function has been set to Switching output 2 (see Section 8-2-23-1 Pin assignments). 38 Display window for new sensor settings New settings of E3NT-L 8-2-1-2 Setting switching points Section 8-2 Switching points A to D can be set in the Switching distances box. Actuating the key minimum distance the display changed to the maximum distance. Switching points B and D and the sliders B and D can only be set if the mode of the Outputs 1 or 2 has been set to window evaluation. The Teach buttons C and D are each activated if the Connector pin 2 function has been set to Switching output 2 (see Section 8-2-2-3-1 Pin assignments). The distance that is currently measured by the sensor is indicated by a bar graph and as a numeric value under min/max. The switching points can be set in several ways: · By means of sliders A to D The positions of the sliders can be altered by dragging with the mouse. The resulting set switching distance is displayed under the sliders as a numeric value for the relevant switching point. · Number input in the case of Switching distances A to D When Switching distance is selected, the switching distance of the relevant switching point can be entered as a number. The resulting set switching distance is set on the relevant slider. The numeric value can be increased or reduced with the adjacent Increment and Decrement buttons. 39 Display window for new sensor settings New settings of E3NT-L Section 8-2 8-2-2 In-/outputs tab In the In-/outputs tab, all parameters of the sensor that are related to inputs and outputs can be set in three submenu tabs. 8-2-2-1 Output 1 submenu tab The output parameters for Output 1 are set in the Output 1 submenu. 40 Display window for new sensor settings New settings of E3NT-L 8-2-2-1-1 Function Section 8-2 The mode of the output is set in the Function box: Background suppression BGS (factory default) The background suppression mode can be set separately for both outputs. Measured objects are detected as from the blind zone up to the setted or teached switching point SA Objects in the background, behind the setted or teached switching point SA, are ignored. Foreground suppression FGS The foreground suppression mode can be set separately for both outputs. Measured objects are detected as from the setted or teached switching point SA up to the maximum sensing distance. Objects in the foreground, between the sensor and the setted or teached switching point SA, are ignored. Window evaluation The window evaluation mode can be set separately for both outputs. Measured objects are only detected in the measurement window between the two setted or teached switching points (switching zone). Objects outside of this measurement window in the foreground and in the background are ignored. 8-2-2-1-2 Switching inversion Switching inversion of the output is set in the Switching inversion box. This parameter can be set separately for both outputs. Light-On (factory default) The output is active when one measured object is detected. Dark-On The output is active when no measured object is detected. 41 Display window for new sensor settings New settings of E3NT-L 8-2-2-1-3 On-switching mode Section 8-2 The on delay of the output is set in the On-switching mode box. This parameter can be set separately for both outputs. [. . . ] · Keylock With the key lock function, the push buttons on the sensor can be locked to prevent unintentional changing of the settings. The lock can be switched on and off on the sensor. When the key lock is active, changes can only be made after the Minus and Plus buttons are pressed simultaneously for 4 seconds. This temporarily suppresses the key lock. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON SENSOR SUPPORT SOFTWARE S3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON SENSOR SUPPORT SOFTWARE S3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag