User manual OMRON V680

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON V680. We hope that this OMRON V680 user guide will be useful to you.

Lastmanuals help download the user guide OMRON V680.


OMRON V680 : Download the complete user guide (2160 Ko)

You may also download the following manuals related to this product:

   OMRON V680 BROCHURE (876 ko)
   OMRON V680 MANUAL 2 (2287 ko)
   OMRON V680 DATASHEET (6163 ko)

Manual abstract: user guide OMRON V680

Detailed instructions for use are in the User's Guide.

[. . . ] Z262-E1-02A Amplifier and Antennas V680-HA63A V680-HS52 V680-HS63 ID Tags V680-D1KP52MT V680-D1KP66T V680-D1KP66MT V680 Series USER'S MANUAL Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. · Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. · Read and understand this manual before attempting to use the RFID System and use the RFID System correctly. [. . . ] (When V680-HS63-W or V680-HS52-W is connected) IP40 (IEC 60529) (When V680-HS63-R or V680-HS52-R is connected) V680-HA63A Ambient operating temperature Ambient storage temperature Ambient operating humidity Insulation resistance Dielectric strength Degree of protection 12. 8 dia. 40 25 9. 5 dia. 25 Connector 15 35. 6 3. 5 25 Connector Round, vinyl-insulated cable (5. 8 dia. ), standard length: 5 m, (41/0. 16 dia) 2 conductors, (17/0. 08 dia. ) 8 conductors Case material Cable 15 dia. Section 2 Amplifier Dielectric strength Shock resistance Dimensions Materials Weight Cable length 10 to 500 Hz, 1. 5-mm double amplitude, acceleration:100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each 500 m/s2, 3 times each in 6 directions (Total: 18 times) 25 × 40 × 65 mm (Not including protrusions. ) PC Approx. 650 g (with 10 m cable) Standard lengths of 5 and 10 m Note: The maximum total cable extension is 50 m (including the Amplifier cable). A maximum of two extension cables can be connected. Dimensions Operation indicator 13. 7 65 18 51 36 PC resin PVC 24 RFID System User's Manual Section 2 Specifications and Performance Nomenclature Antenna connection port RUN COMM NORM ERR Operation indicators Section 2 Amplifier LV6/7D LV5/7A LV4/76 LV3/72 LV2/71 LV1/70 Controller connector Antenna Connection Port The Antenna connection port is connected a V680-series Antenna. Controller Connector The Controller connector is connected to Antenna connection port on the Controller. Operation Indicators (LEDs) Name RUN COMM NORM ERR LV6/7D LV5/7A LV4/76 LV3/72 LV2/71 LV1/70 Color Green Lit when the power is ON. Meaning Green Lit when communications with a Tag are normal in Normal Communications Mode. Red Yellow Yellow Yellow Yellow Yellow Yellow Lit when an error occurs in communications with a Tag in Normal Communications Mode. Normal Communications Mode: Lit when a Tag communications error occurs. The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment. Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does not indicate a malfunction. RFID System User's Manual 25 Section 2 Specifications and Performance Cables Specifications Item Model V700-A43/V700-A44 Number of conductors 10 Insulation resistance Dielectric strength 5 M min. (at 500 VDC) between terminals and sheath 500 VAC, 1 min 6 dia. Connector (Controller end)) Connector (Amplifier end) Connection label (Unit: mm) Casing material PVC 26 RFID System User's Manual 15. 5 dia. 15 dia. Section 2 Amplifier Dimensions Item Model V700-A43 Approx. 10m Approx. 20 m Approx. 1, 350 g Length (L1) Weight 51 L1±100 49 Section 2 Specifications and Performance Tags Specifications and Dimensions V680-D1KP52MT · General Specifications Item Memory capacity Memory type Data backup time Memory longevity Ambient operating temperature when communicating Ambient operating temperature when not communicating Ambient storage temperature Ambient operating humidity Degree of protection Vibration resistance Shock resistance Dimensions Materials Weight Metal countermeasures Model 1, 000 bytes (user area) EEPROM 10 years after writing (85°C or less) 100, 000 times per block (25°C) -25 to 85°C (with no icing) V680-D1KP52MT Section 2 Tags -40 to125°C (with no icing) -40 to 125°C (with no icing) 35% to 95% IP68 (IEC 60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) 10 to 2, 000 Hz, 1. 5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) 8 dia. 0. 5 g Yes · Dimensions R0. 2 8 -0. 1 dia. 0 5 -0. 1 (Unit : mm) 0 Case material Fill resin PPS resin Epoxy resin When embedding the V680-D1KP52MT into a metal surface, use the V680-HS52 Antenna. Transmission will not be possible if the V680-HS63 Antenna is used. The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. RFID System User's Manual 27 Section 2 Specifications and Performance V680-D1KP66T/66MT · General Specifications Item Memory capacity Memory type Data backup time Memory longevity Ambient operating temperature when communicating Ambient operating temperature when not communicating Ambient storage temperature Ambient operating humidity Degree of protection Vibration resistance Shock resistance Dimensions Materials Weight Metal countermeasures Model V680-D1KP66T 1, 000 bytes (user area) EEPROM 10 years after writing (85°C or less) 100, 000 times per block (25°C) -25 to 85°C (with no icing) V680-D1KP66MT Section 2 Tags -40 to125°C (with no icing) -40 to 125°C (with no icing) 35% to 95% IP68 (IEC 60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) 10 to 2, 000 Hz, 1. 5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) 34 × 34 × 3. 5 mm Case: PPS resin Approx. 7. 5 g Yes The V680-D1KP66MT is designed to be mounted directly to metal. The V680-D1KP66T and V680D1KP66MT markings are shown in the following diagrams. V680-D1KP66MT V680-D1KP66T V680-D1KP66MT XXXXXX V680-D1KP66T XXXXXX MADE IN JAPAN MADE IN JAPAN The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. 28 RFID System User's Manual Section 2 Specifications and Performance · Dimensions V680-D1KP66T/66MT Four, R4 25+0. 2 Four, R3 Mounting Hole Dimensions Two, M3 34 32 25+0. 2 Two, 3. 5 dia. Two, 6 dia. 25+0. 2 Section 2 Tags 32 34 3. 5+0. 1 25+0. 2 Case material PPS resin V600-A86 Attachment Four, R5. 5 25+0. 2 Two, 4 dia. Two, M3 37 34 15 25+0. 2 16 25+0. 2 25+0. 2 15 34 37 3. 5 10 4 Case material PPS resin Tag Heat Resistivity · Storing Tags under high temperatures will adversely affect the performance of the internal parts and the service life of the Tags. · An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after testing under the following test conditions. Heat cycle High temperatures -10°C/+150°C, 30 minutes each for 1, 000 cycles -100°C/+180°C, 30 minutes each for 200 cycles +150°C, 1, 000 hours +180°C, 200 hours LTPD: Lot tolerance percent defective The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing. RFID System User's Manual 29 Section 2 Specifications and Performance Memory Map Address Data 0000 0001 Section 2 Tags tion Setting Area). H H H H 0002 0003 User area 03DF 03E7 H H 1 byte EEPROM is used as memory in the Tags. The memory capacity available to the user is 1, 000 bytes, including 0000H to 0003H (the Write ProtecThe access to the memory is executed at every block. 1 block is 8 bytes (8 addresses). 30 RFID System User's Manual Section 2 Specifications and Performance Write Protection Function The write protection function prevents important data, such as product information, stored in memory in a Tag from being inadvertently overwritten. After important data has been written to memory, it can be write-protected using the following method. The write protect function setting can be switched with switches 4 to 7 (Write Protect Function Setting) of the V680CA5D [. . . ] 3, Yushiroken EEE-30Y Note: The above results are from tests conducted a room temperature (23°C). Even if the chemicals do not affect the ABS or epoxy resins at room temperature, they may affect the resins at higher or lower temperatures. Check the chemicals carefully in advance. 60 RFID System User's Manual Section 5 Chemical Resistance Chemical Resistance of Tags Applicable Models V680-D1KP66T/66MT Chemical Hydrochloric acid Sulfuric acid 37% 10% 98% 50% 30% 3% At room temperature A A A A A A B A A A A A A A A A A A A A A At 90°C A A B A A A C B A A A B A A A A B B A A A Chemical Sodium hypochlorite Phenol solution Glacial acetic acid Acetic acid Oleic acid Methyl alcohol Ethyl alcohol Ethyl acetate Sebacic acid diethylhexyl Acetone Diethyl ether n-heptane 2-2-4 trimethylpentane Benzene Toluene Aniline Mineral oil Gasoline Insulating oil Dichloroethylene Carbon tetrachloride 95% 95% 5% At room temperature A A A A A A A A A A A A A A A A A A A A A At 90°C A A A A A A A A Nitric acid 60% 40% 10% Section 5 Chemical Resistance of Tags A A A A A A A A A A A A A Hydrogen fluoride solution 40% Chromic acid Hydrogen peroxide solution 40% 28% 3% Sodium hydroxide solution 60% 10% 1% Ammonia solution Sodium chloride Sodium carbonate 28% 10% 10% 20% 2% A: Has no adverse effect, B: May cause discoloration, swelling, etc. , C: Causes deformation, cracks, etc. The above table shows the extent of changes in PPS resin exposed to each chemical at room temperature and at 90°C. If actual chemicals, concentrations, and temperatures are different from those shown in the tables, always conduct tests under the actual conditions in which the Tags are to be used. RFID System User's Manual 61 Section 5 Chemical Resistance Applicable Model V680-D1KP52MT PPS resin is used for case material and epoxy resin for filling material. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V680

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V680 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag