[. . . ] Conforms to International Standards ISO/IEC 18000-3 (ISO/IEC 15693) V680 RFID DeviceNet ID Slave V680-HAM42-DRT ID Flag Sensors V680-HAM91/HAM81 RFID with Open Network Compatibility! V680-HAM42-DRT Read and write up to 58 bytes. Use the DeviceNet open network for easier, more-flexible information management on factory sites. The RFID System Can Be Used Just Like a Sensor. V680-HAM91/HAM81 Read or write 16 bits at a time with one unit. Useful in applications from simple line sorting or product identification to managing work progress or inspection data. V680 DeviceNet ID Slave V680-HAM42-DRT V680-series DeviceNet-compatible Slaves for RFID Systems. Read and Write Up To 58 Bytes. · V680-series DeviceNet-compatible Slaves for RFID systems. [. . . ] The address shift can be set from the host, eliminating the need to change the address set on the front panel. Prevents data stored in the ID Tag from being overwritten. Noise Check Write Protection Operating Modes Mode Function AUTO MODE 1 TRIGGER MODE 1 Reading 16 bits Verification Check Wire-saving Mode (See note 2. ) Writing 8 bits (1 byte) 16 bits (2 bytes) Parity check output (See note 3. ) Noise check function Address shift function Standard modes V600-HAR91/81 and HAM91/81-compatible modes AUTO MODE 2 TRIGGER MODE 2 () (See note 1. ) V600-HAR92-compatible modes AUTO MODE 3 TRIGGER MODE 3 Individual bits (BIT SET or BIT CLEAR) Note 1. If an error occurs, the error code will not be output to the data output lines (OD0 to OD15). The V600-compatible modes are for compatibility with the previous V600 Series. Not all functions are supported in these modes. 10 V680-HAM42-DRT, V680-HAM91/-HAM81 Performance Specifications ID Tag (1-kbyte Memory) Transmission Recommended combination ID Tag V680-D1KP52MT Read/Write Antenna V680-HS51 Read distance Function Transmission distance (unit: mm) 0. 5 to 6. 5 mm (axial deviation ±2) ID Tag and Read/Write Antenna mounting conditions V680-D1KP52MT Write distance 0. 5 to 6. 0 mm (axial deviation ±2) Metallic V680HS51 Non-metallic (Resin, plastic, wood, etc. ) V680-HS52 Read distance 0. 5 to 9. 0 mm (axial deviation ±2) V680-D1KP52MT V680-HS52 Write distance 0. 5 to 8. 5 mm (axial deviation ±2) Non-metallic Non-metallic (Resin, plastic, wood, etc. ) V680-D1KP52MT (embedded in metallic surface: steel) V680-HS51 Read distance 0. 5 to 3. 5 mm (axial deviation ±2) V680HS51 Metallic V680-D1KP52MT Metallic Write distance 0. 5 to 3. 0 mm (axial deviation ±2) V680-HS52 Read distance 0. 5 to 4. 5 mm (axial deviation ±2) Metallic V680-HS52 Write distance 0. 5 to 4. 0 mm (axial deviation ±2) Non-metallic V680-D1KP52MT V680-D1KP52MT V680-HS63 Read distance 0. 5 to 12. 0 mm (axial deviation ±2) V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) Write distance 0. 5 to 9. 5 mm (axial deviation ±2) Non-metallic V680D1KP52MT Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 × 100 mm). The transmission distance may be reduced if the V680-D1KP66T or V680-D1KP58HT is mounted onto a metallic surface. Z221) for details. V680-HAM42-DRT, V680-HAM91/-HAM81 11 Recommended combination ID Tag V680-D1KP66T Read/Write Antenna V680-HS52 Function Read distance Transmission distance (unit: mm) 1. 0 to 17. 0 mm (axial deviation ±2) (See note 2. ) 1. 0 to 17. 0 mm (axial deviation ±2) (See note 2. ) ID Tag and Read/Write Antenna mounting conditions V680-D1KP66T V680-HS52 Write distance Non-metallic Non-metallic (Resin, plastic, wood, etc. ) V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) V680-HS63 Read distance 5. 0 to 30. 0 mm (axial deviation ±10) (See note 2. ) 5. 0 to 25. 0 mm (axial deviation ±10) (See note 2. ) 5. 0 to 47. 0 mm (axial deviation ±10) (See note 2. ) 5. 0 to 42. 0 mm (axial deviation ±10) (See note 2. ) Metallic Write distance V680D1KP66T Non-metallic V680-HS65 Read distance V680-HS65 Non-metallic (Resin, plastic, wood, etc. ) Write distance V680D1KP66T V680-D1KP66MT (flush-mounted on metallic surface: steel) V680-HS52 Read distance 1. 0 to 16. 0 mm (axial deviation ±2) V680-D1KP66MT Write distance 1. 0 to 14. 0 mm (axial deviation ±2) V680-HS52 Non-metallic Metallic V680-HS63 Metallic V680-HS63 Read distance 5. 0 to 25. 0 mm (axial deviation ±10) Write distance 5. 0 to 20. 0 mm (axial deviation ±10) V680D1KP66MT Non-metallic V680-HS65 Read distance 5. 0 to 25. 0 mm (axial deviation ±10) V680-HS65 Metallic Write distance 5. 0 to 20. 0 mm (axial deviation ±10) Metallic V680D1KP66MT 12 V680-HAM42-DRT, V680-HAM91/-HAM81 Recommended combination ID Tag V680-D1KP66T-SP Read/Write Antenna V680-HS52 Function Read distance Transmission distance (unit: mm) 1. 0 to 15. 0 mm (axial deviation ±2) ID Tag and Read/Write Antenna mounting conditions V680-D1KP66T-SP Non-metallic (Resin, plastic, wood, etc. ) Write distance 1. 0 to 15. 0 mm (axial deviation ±2) Non-metallic V680HS52 V680-HS63 Read distance 5. 0 to 25. 0 mm (axial deviation ±10) V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) Write distance 5. 0 to 20. 0 mm (axial deviation ±10) Non-metallic V680D1KP66T-SP V680-HS65 Read distance 5. 0 to 42. 0 mm (axial deviation ±10) V680-HS65 Non-metallic (Resin, plastic, wood, etc. ) Write distance 5. 0 to 37. 0 mm (axial deviation ±10) Metallic V680D1KP66T-SP Note 1. When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 × 100 mm). Z221) for details. V680-HAM42-DRT, V680-HAM91/-HAM81 13 ID Tag (2-kbyte Memory) Transmission Recommended combination ID Tag V680-D2KF52M Read/Write Antenna V680-HS51 Read distance Write distance V680-HS52 Read distance Write distance V680-D2KF52M (embedded in metallic surface: steel) V680-HS51 Read distance Write distance V680-HS52 Read distance Write distance V680-D2KF52M V680-HS63 Read distance Function Transmission distance (unit: mm) 0. 5 to 5. 5 mm (axial deviation ±2) 0. 5 to 5. 5 mm (axial deviation ±2) Metallic ID Tag and Read/Write Antenna mounting conditions V680-D2KF52M Non-metallic (Resin, plastic, wood, etc. ) V680HS51 0. 5 to 8. 0 mm (axial deviation ±2) 0. 5 to 8. 0 mm (axial deviation ±2) Non-metallic V680-D2KF52M V680-HS52 Non-metallic (Resin, plastic, wood, etc. ) 0. 5 to 3. 5 mm (axial deviation ±2) V680HS51 Metallic 0. 5 to 3. 5 mm (axial deviation ±2) 0. 5 to 3. 0 mm (axial deviation ±2) Metallic V680-D2KF52M Metallic V680-HS52 0. 5 to 3. 0 mm (axial deviation ±2) Non-metallic V680-D2KF52M V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) 0. 5 to 9. 5 mm (axial deviation ±2) Write distance 0. 5 to 9. 5 mm (axial deviation ±2) Non-metallic V680D2KF52M V680-D2KF67 V680-HS52 Read distance Write distance 1. 0 to 17. 0 mm (axial deviation ±2) (See note. ) 1. 0 to 17. 0 mm (axial deviation ±2) (See note. ) 7. 0 to 30. 0 mm (axial deviation ±10) (See note. ) 7. 0 to 30. 0 mm (axial deviation ±10) (See note. ) Non-metallic V680-D2KF67 V680-HS52 Non-metallic Non-metallic (Resin, plastic, wood, etc. ) V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) V680-HS63 Read distance Write distance V680D2KF67 V680-HS65 Read distance 5. 0 to 42. 0 mm (axial deviation ±10) (See note. ) 5. 0 to 42. 0 mm (axial deviation ±10) (See note. ) Metallic V680-HS65 Non-metallic (Resin, plastic, wood, etc. ) Write distance V680D2KF67 14 V680-HAM42-DRT, V680-HAM91/-HAM81 Recommended combination ID Tag Read/Write Antenna V680-D2KF67M (flush- V680-HS52 mounted on metallic surface: steel) Function Read distance Write distance Transmission distance (unit: mm) 1. 0 to 16. 0 mm (axial deviation ±2) 1. 0 to 16. 0 mm (axial deviation ±2) 6. 0 to 25. 0 mm (axial deviation ±10) ID Tag and Read/Write Antenna mounting conditions V680-D2KF67M Metallic V680-HS52 Non-metallic Iron V680-HS63 Metallic V680-HS63 Read distance Write distance 6. 0 to 25. 0 mm (axial deviation ±10) Non-metallic V680D2KF67M V680-HS65 Read distance 5. 0 to 25. 0 mm (axial deviation ±10) V680-HS65 Metallic Write distance 5. 0 to 25. 0 mm (axial deviation ±10) Metallic V680D2KF67M ID Tag (8-/32-Kbyte Memory) Transmission Recommended combination ID Tag V680-D8KF68/ -D32KF68 Read/Write Antenna V680-HS63 Read distance Function Transmission distance (unit: mm) 5. 0 to 45. 0 mm (axial deviation ±10) (See note. ) 5. 0 to 45. 0 mm (axial deviation ±10) (See note. ) Metallic ID Tag and Read/Write Antenna mounting conditions V680-HS63 Non-metallic (Resin, plastic, wood, etc. ) Write distance V680D@KF68 V680-HS65 Read distance 5. 0 to 75. 0 mm (axial deviation ±10) (See note. ) V680-HS65 Non-metallic (Resin, plastic, wood, etc. ) Write distance 5. 0 to 75. 0 mm (axial deviation ±10) (See note. ) Metallic V680D@KF68 V680-D8KF68/ V680-HS63 -D32KF68 (Special attachment provided; flush-mounted on metallic surface: steel) Read distance 5. 0 to 35. 0 mm (axial deviation ±10) V680-HS63 V680-A81 (ID Tag Attachment) Metallic Write distance 5. 0 to 35. 0 mm (axial deviation ±10) Metallic V680D@KF68 V680-HS65 Read distance 5. 0 to 55. 0 mm (axial deviation ±10) V680-HS65 V680-A81 (ID Tag Attachment) Metallic Write distance 5. 0 to 55. 0 mm (axial deviation ±10) V680D@KF68 Metallic Note: When mounting the V680-HS65, be sure to attach the Mounting Brackets at the base of the Antenna. The enclosed Mounting Brackets do not need to be used, however, if the mounting brackets on the Antenna are metal plates and their dimensions are larger than the dimensions of the Antenna (100 × 100 mm). Note: The transmission distance may be reduced if the V680-D1KP66T or V680-D1KP58HT is mounted onto a metallic surface. Z221) for details. V680-HAM42-DRT, V680-HAM91/-HAM81 15 Characteristic Data (Typical) Transmission Range 1-kbyte Memory ID Tag The values given for communications ranges are reference values. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system. (unit: mm) V680-HS52 (embedded in non-metallic material) & V680-D1KP52MT Read Y 50 40 30 20 10 -50 -40 -30 -20 -10 X Y V680-HS52 (embedded in non-metallic material) & V680-D1KP52MT (embedded in metallic surface: steel) Write Read Y 50 40 30 20 10 X Y Write 0 10 20 30 40 X -50 -40 -30 -20 -10 0 10 20 30 40 X V680-HS51 (embedded in metallic material) & V680-D1KP52MT Read Y 50 40 30 20 10 -50 -40 -30 -20 -10 X Y V680-HS51 (embedded in metallic material) & V680-D1KP52MT (embedded in metallic surface: steel) Write Y Y Read Write 50 40 30 20 10 -50 -40 -30 -20 -10 X 0 10 20 30 40 X 0 10 20 30 40 X V680-HS63 (mounted on non-metallic material) & V680-D1KP52MT Read Y 50 40 30 20 10 X Y V680-HS52 (embedded in non-metallic material) & V680-D1KP66T Write Y 50 40 30 20 10 X Y Read Write -50 -40 -30 -20 -10 0 10 20 30 40 X -50 -40 -30 -20 -10 0 10 20 30 40 X V680-HS63 (mounted on non-metallic material) & V680-D1KP66T Read Write V680-HS65 (mounted on metallic material) & V680-D1KP66T Read Write Y 50 40 30 20 10 -50 -40 -30 -20 -10 0 10 20 30 40 X -100 -80 -60 -40 -20 X Y Y 100 80 60 40 20 0 20 40 60 80 X 16 V680-HAM42-DRT, V680-HAM91/-HAM81 V680-HS52 (embedded in non-metallic material) & V680-D1KP66T-SP Read Y 50 40 X Y V680-HS63 (mounted on non-metallic material) & V680-D1KP66T-SP Write Y 50 40 X Y Read Write 30 20 10 -50 -40 -30 -20 -10 -50 -40 -30 -20 -10 30 20 10 0 10 20 30 40 X 0 10 20 30 40 X V680-HS65 (mounted on metallic material) & V680-D1KP66T-SP Read Y 100 80 60 40 20 Write V680-HS52 (embedded in non-metallic material) & V680-D1KP66MT (flush-mounted on metallic surface: steel) Read Y 50 40 30 20 10 -50 -40 -30 -20 -10 X Y Write -100 -80 -60 -40 -20 0 20 40 60 80 X 0 10 20 30 40 X V680-HS63 (mounted on non-metallic material) & V680-HS65 (mounted on metallic material) & V680-D1KP66MT (flush-mounted on metallic surface: steel) V680-D1K66MT (flush-mounted on metallic surface: steel) Read Y 50 40 30 20 10 -50 -40 -30 -20 -10 -100 -80 -60 -40 -20 X Y Write Y 100 80 60 40 20 Read Write 0 10 20 30 40 X 0 20 40 60 80 X V680-HAM42-DRT, V680-HAM91/-HAM81 17 2-kbyte Memory ID Tag The values given for communications ranges are reference values. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system. V680-HS52 (embedded in non-metallic material) & V680-D2KF52M Read Y 60 50 40 30 20 10 X Y V680-HS52 (embedded in non-metallic material) & V680-D2KF52M (embedded in metallic surface: steel) Read Y 60 50 40 30 20 10 X Y Write Write -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X V680-HS51 (embedded in metallic material) & V680-D2KF52M Read Y 50 40 30 20 10 -50 -40 -30 -20 -10 X Y V680-HS51 (embedded in metallic material) & V680-D2KF52M (embedded in metallic surface: steel) Write Y 50 40 30 20 10 -50 -40 -30 -20 -10 X Y Read Write 0 10 20 30 40 X 0 10 20 30 40 X V680-HS63 (mounted on non-metallic material) & V680-D2KF52M Read Y 60 50 40 X Y V680-HS52 (embedded in metallic material) & V680-D2KF67 Write Y 60 50 40 30 20 10 X Y Read Write 30 20 10 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X V680-HS63 (mounted on non-metallic material) & V680-D2KF67 Read Y 60 50 40 30 20 10 X Y V680-HS65 (mounted on metallic material) & V680-D2KF67 Write Y 90 80 70 60 50 40 30 20 10 Read Write -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X -100 -80 -60 -40 -20 0 20 40 60 80 X 18 V680-HAM42-DRT, V680-HAM91/-HAM81 V680-HS52 (embedded in non-metallic material) & V680-D2KF67M (flush-mounted on metallic surface: steel) Read Y 60 50 40 30 20 10 X Y V680-HS63 (mounted on non-metallic material) & V680-D2KF67M (flush-mounted on metallic surface: steel) Read Y 60 50 40 30 20 10 X Y Write Write -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 X V680-HS65 (mounted on metallic material) & V680-D2KF67M (flush-mounted on metallic surface: steel) Read Y 90 80 70 60 50 40 30 20 10 Write -100 -80 -60 -40 -20 0 20 40 60 80 X V680-HAM42-DRT, V680-HAM91/-HAM81 19 8-/32-Kbyte Memory ID Tag The values given for communications ranges are reference values. The communications distance will depend on the ID Tags, ambient temperature, surrounding metal, noise, and other factors. Test operation completely when installing a system. V680-HS63 (mounted on metallic material) & V680-D8KF68/-D32KF68 (Horizontal-facing ID Tag) Read Y 70 60 50 40 30 20 10 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 X X Y V680-HS63 (mounted on metallic material) & V680-D8KF68/-D32KF68 (Vertical-facing ID Tag) Read Y 70 60 50 40 30 20 10 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 X X Y Write Write V680-HS63 (mounted on metallic material) & V680-D8KF68/-D32KF68 Flush-mounted on metallic surface: steel (Horizontalfacing ID Tag) When the V680-A81 ID Tag Attachment is mounted. Read Y 70 60 50 40 30 20 10 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 X X Y V680-HS63 (mounted on metallic material) & V680-D8KF68/-D32KF68 Flush-mounted on metallic surface: steel (Vertical-facing ID Tag) When the V680-A81 ID Tag Attachment is mounted. Read Y 70 60 50 X Y Write Write 40 30 20 10 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 X V680-HS65 (mounted on metallic material) & V680-D8KF68/-D32KF68 (Horizontal-facing ID Tag) Read Y 110 100 90 80 70 60 50 40 30 20 10 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X Write V680-HS65 (mounted on metallic material) & V680-D8KF68/-D32KF68 (Vertical-facing ID Tag) Read Y 110 100 90 80 70 60 50 40 30 20 10 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X Write Y Y X X V680-HS65 (mounted on metallic material) & V680-D8KF68/-D32KF68 Flush-mounted on metallic surface: steel (Horizontal-facing ID Tag) When the V680-A81 ID Tag Attachment is mounted. Read Y 110 100 90 80 70 60 50 40 30 20 10 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X Write V680-HS65 (mounted on metallic material) & V680-D8KF68/-D32KF68 Flush-mounted on metallic surface: steel (Vertical-facing ID Tag) When the V680-A81 ID Tag Attachment is mounted. Read Y 110 100 90 80 70 60 50 40 30 20 10 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X Write Y Y X X 20 V680-HAM42-DRT, V680-HAM91/-HAM81 Processing Times (for reference purposes only) Communications times between the Antenna and ID Tag, plus the processing time for the Amplifier. V680-HAM42-DRT (DeviceNet ID Slave) 1-Kb Memory Tag V680-D1KP@ (V680-HS Antenna) Communications speed setting Normal mode Read Data Fill High-speed mode Read Data Fill Command Communications time (ms) 4-byte Access Mode 26-byte Access Mode 58-byte Access Mode 67 95 143 85 128 137 210 117 186 V600-compatible Mode 67 105 --------- Write (with verification) 105 63 17. 5 × number of processed blocks + 89. 2 Write (with verification) 89 14. 8 × number of processed blocks + 71. 7 2-Kb Memory Tag V680-D2KF@ (V680-HS [. . . ] IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V680 RFID

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V680 RFID will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag