User manual OMRON WD30-ME01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON WD30-ME01. We hope that this OMRON WD30-ME01 user guide will be useful to you.

Lastmanuals help download the user guide OMRON WD30-ME01.


Mode d'emploi OMRON WD30-ME01
Download
Manual abstract: user guide OMRON WD30-ME01

Detailed instructions for use are in the User's Guide.

[. . . ] M071-E1-01A WD30-ME/-SE/-ME01/-SE01 DeviceNet Wireless Units OPERATION MANUAL Notice (1) This manual may not be copied, reproduced, or reprinted, in whole or in part, without permission. (2) The specifications listed within this manual may be revised without prior notice. (3) The information in this manual was compiled with the utmost care. However, if you should find any errors or inconsistencies, please contact the OMRON business office. [. . . ] · The purpose of each test is as follows. Test Installation test Content/Purpose Adjusts the installation position (confirmation of receiving wave, etc. ) and the setup conditions (selection of available frequencies). Both master and slave stations require the switch Checks the wireless communication status with each slave station in a system in operation. This is a switch operation from the master station. Test timing At installation At advance on-site test Confirmation test At confirmation after installation At maintenance and inspection Wireless channel monitor Obtains the receiving wave level of the frequency band (all At installation channels) to allow for the selection of the available channels At advance on-site test (frequency band). 72 Installation Test Section 5-2 5-2 Installation Test This test is for adjusting the installation position (confirmation of receiving wave, etc. ) and the setup conditions (selection of unused frequencies, selection of transmission output, etc. ) at installation. Both master and slave stations require the switch operation. 5-2-1 Preparation · The DeviceNet master and DeviceNet slave do not need to be connected for the installation test. · Set the WNODE switch of the wireless master station to "00" and the WNODE switch of a wireless slave station to "01" to "64", avoiding duplication. · Since both the wireless master stations and wireless slave stations require the transmission power supply, connect them to the power supply via the DeviceNet cable prepared for a micro-connector. 5-2-2 Test procedure Master station W NODE 901 901 X10 X1 901 SW2 RUN TEST SET 78 W CH 901 X10 X1 SW3 ON 12345678 1. Set the mode select switch of the wireless master station to "TEST", and the WNODE switch to the WNODE number of the wireless slave station to be tested. "01" is used for this example. Set SW3 to "bit 4 = ON". 78 78 78 456 23 23 23 Slave station W NODE 901 901 78 78 X10 SW2 RUN TEST SET 78 W CH 901 78 X10 SW3 ON 12345678 Master station MS NS WS Slave station MS NS WS N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 X10 X1 SW1 ON 1234 X10 X1 SW1 ON 1234 Master station MS NS WS Slave station MS NS WS N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 X10 X1 X10 X1 SW1 ON 1234 SW1 ON 1234 456 456 456 456 456 456 23 456 23 23 456 456 2. Set the mode select switch of the wireless slave station to "TEST". X1 901 X1 23 23 3. Turn on the communication power supplies of the wireless master station and all wireless slave stations. The system is in test operation status. 23 23 23 456 23 456 456 456 456 456 4. The LED display shows the receiving wave level "L1 to L9", if the wireless master station and the wireless slave station to be tested have been installed within the distance where both stations can receive the electric wave from each other. 73 Installation Test Section 5-2 If the WS LED lights green, this means that the wireless communication link has been established. Position the devices so that the WS LED lights green. If the electric wave is weak, adjust the position of the wireless slave station so that receiving wave level is stabilized in L5 or higher. Master station MS Slave station WS MS NS WS NS The LED display shows the receiving wave level "L0" if the devices have been installed N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 outside the distance where they cannot receive the electric wave from each other. Set the WNODE switch of the wireless master station to the WNODE number ("00" for this example) of the wireless slave station to be tested next, and then press SW2. Repeat this procedure till the communication with all wireless slave stations is established and stabilized. 23 ON 23 X10 X1 X10 SW1 1234 SW1 ON 1234 Master station W NODE 901 901 78 78 78 456 X10 SW2 RUN TEST SET 78 X10 SW3 ON 12345678 74 456 456 456 456 456 456 456 X1 W CH 901 23 23 X1 901 X1 23 23 Confirmation Test Section 5-3 5-3 Confirmation Test This test is for checking the wireless communication status with each slave station in the system in operation after installation. The test can be implemented by the switching operation from the master station. 5-3-1 Preparation · The DeviceNet master does not need to be connected for the confirmation test. (The DeviceNet slave needs to be connected. ) · The confirmation test is employed for the inspection work after installation. Thus, the system registration is assumed to be completed beforehand. · Leave the mode select switches of the wireless slave stations in the "Run" position. 5-3-2 Test procedure Master station W NODE 901 901 X10 X1 901 SW2 RUN TEST SET 78 W CH 901 X10 X1 SW3 ON 12345678 1. Set the mode select switch of the wireless master station to "TEST", and the WNODE switch to the WNODE number of the wireless slave station to be tested. [. . . ] characteristics 7 Produced connection size 8 Consumed connection size 9 Expected packet rate 12 Watchdog time-out action 13 Produced connection path length 14 Produced connection path 15 Consumed connection path length 16 Consumed connection path Service DeviceNet service 0E Get_Attribute_Single 10 Set_Attribute_Single 0100H 0400H 0800H 0000H 0000H No 0000H Parameter option No No 159 Appendix B Connection-related Devices Model List Basic unit Model WD30-ME WD30-SE WD30-ME01 WD30-SE01 Specifications DeviceNet wireless master station (pencil antenna) Manufacturer OMRON DeviceNet wireless slave station (pencil antenna) OMRON DeviceNet wireless master station (magnet-base antenna) OMRON DeviceNet wireless slave station (magnet-base antenna) OMRON Configurator Model 3G8F5-DRM21 3G8E2-DRM21 WS02-CFDC1-E Specifications ISA board compatible configurator Manufacturer OMRON PCMCIA card compatible configurator OMRON Installation disk (CD-ROM) OMRON Connection cable for DeviceNet Model DCA1-5CNC01F1 DCA1-5CNC02F1 DCA1-5CNC03F1 DCA1-5CNC05F1 DCA1-5CNC10F1 Specifications Manufacturer Connection cable for DeviceNet Cable OMRON with connector at one side (socket side) Power supply for communication Model S82K-03024*1 S82J-0224*2 S82J-2224 S82J-5224 S82J-6224 Specifications Switching power supply Switching power supply Manufacturer OMRON OMRON *1: type of 30W or above *2: type of 25W or above Connector with terminating resistors Model DRS2-1 DRS2-2 Specifications Manufacturer Shielded terminating resistors (plug) OMRON Shielded terminating resistors (socket) OMRON T-branch connector Model DCN2-1 Specifications Shielded T-branch connector Manufacturer OMRON 161 Appendix C Current Consumption List Current Consumption List Model WD30-ME/-ME01 WD30-SE/-SE01 *1 Total current consumption Max. 350mA *1 The wireless unit receives the total power supply from the communication power supply via the dedicated DeviceNet cable. Thus, the total power supply listed here does not distinguish the internal circuit area from the communication area. Taking the maximum current at startup into consideration, however, use a power supply of at least 350mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON WD30-ME01

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON WD30-ME01 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag