User manual OMRON WT30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON WT30. We hope that this OMRON WT30 user guide will be useful to you.

Lastmanuals help download the user guide OMRON WT30.


Mode d'emploi OMRON WT30
Download

You may also download the following manuals related to this product:

   OMRON WT30 DATASHEET (405 ko)

Manual abstract: user guide OMRON WT30

Detailed instructions for use are in the User's Guide.

[. . . ] N138-E1-01 WT30 FA Wireless SS Terminal Notice (1) This manual may not be copied, reproduced, or reprinted, in whole or in part, without permission from OMRON. (2) The specifications listed within this manual may be revised without prior notice. (3) The information in this manual was compiled with the utmost care. However, if you should find any errors or inconsistencies, please contact the OMRON business office. [. . . ] Received Signal Strength Indicator Red indicators Field strength Number of indicators lit RUN mode TEST mode Field strength monitor test Installation/confirmation test Weak 0 1 Unstable communications range Range in which specified channel can be used. Unstable communications range The received signal strength is indicated using 10 levels. Check the communications status, referring to the field strength level. 42 456 456 X1 Yellow indicators Medium Green indicators Strong 2 3 4 5 6 7 8 9 Stable communications range Range in which specified channel cannot be used. Stable communications range Using Unregistered Communications Partners Section 3-4 3-4-2 Operation Settings 1, 2, 3. . . Before turning ON the power, set the function setting switch as required. ON 12345678 90 Bit 1: Hold/clear I/O data if communications errors occur Bit 2: Input hold/normal mode Bit 3: Input filter (100 ms/10 ms) I/O Slave Station Settings 2. Set the node number of the I/O Slave Station using the node setting switch. W NODE 901 78 23 901 Setting range: 01 to 64 78 456 23 X10 3. Set the same frequency channel used by the Serial Master Station using the channel setting switch. 78 78 X10 4. Change the setting for the mode setting switch to RUN mode, and then turn ON the power. RUN TEST SET Serial Master Station Settings 1, 2, 3. . . Before turning ON the power set the function setting switch as required. ON 12345678 90 Bit 1: Hold/clear I/O data if communications errors occur Bit 2: OFF (scan list disabled) Note When the scan list is disabled, communications are performed with the number of I/O Slave Stations set using the node setting switch. Example 1: If the node setting switch is set to 2, communications will be performed with up to 02 I/O Slave Stations. Example 2: If the node setting switch is set to 64, communications will be performed with up to 64 I/O Slave Stations. Set the number of I/O Slave Stations to be connected using the node setting switch. Polling will be performed for the number of I/O Slave Stations set here. For example, if the number is set to 2, communications will be performed with only 2 Stations even if 3 or more Stations actually exist. W NODE 901 901 Setting range: 01 to 64 78 78 X10 456 456 456 X1 W CH 901 901 23 Setting range: 01 to 34, 51 to 83 23 23 456 456 X1 X1 23 43 Using Unregistered Communications Partners Section 3-4 3. Set the frequency channel using the channel setting switch. W CH 901 901 Setting range: 01 to 34, 51 to 83 78 78 456 23 23 X10 4. Change the setting for the mode setting switch to RUN mode, and then turn ON the power. 3-4-3 Confirming Connection Status Confirm the communications status between the I/O Slave Stations and Serial Master Station using the RSSI (received signal strength indicator) display. To confirm the status from the Serial Master Station, specify the I/O Slave Station to be monitored using the node setting switch. Be sure to turn ON the power to the I/O Slave Station in RUN mode before the Serial Master Station. I/O Slave Stations 1, 2, 3. . . Confirm that the mode setting switch on the I/O Slave Station is set to RUN mode. 2. Confirm that the MS and WS indicators on the I/O Slave Station are lit green. MS: Module status indicator WS: Wireless status indicator MS 3. Check the strength of the received signal from the Serial Master Station indicated using 10 levels on the RSSI display. Number of LEDs lit: Field strength: Few Weak Many Strong Serial Master Station 1, 2, 3. . . Confirm that the mode setting switch on the Serial Master Station is set to RUN mode. 44 456 X1 RUN TEST SET RUN TEST SET WS RUN TEST SET Registering the Communications Partner Section 3-5 2. Confirm that the MS and WS indicators on the Serial Master Station are lit green. MS: Module status indicator WS: Wireless status indicator MS WS 3. [. . . ] = WNODE (Sum total of cycle times for all I/O Slave Stations) = WNODE (10 ms × n stations) Using Relay Stations The wireless communications delay is doubled when a Relay Station is used. = WNODE (10 ms × n stations × 2) Example 1: Using one Master Station, four I/O Slave Stations, and an input filter of 10 ms. 10 × 4 × 2 + 10 = 90 ms Example 2: Using one Master Station, one Relay Station, four I/O Slave Stations, and an input filter of 10 ms. 10 × 4 × 2 × 2 + 10 = 170 ms The calculations shown here indicate theoretical values and should be considered as a rough guide only. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON WT30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON WT30 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag