User manual OMRON Z500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON Z500. We hope that this OMRON Z500 user guide will be useful to you.

Lastmanuals help download the user guide OMRON Z500.


Mode d'emploi OMRON Z500
Download
Manual abstract: user guide OMRON Z500

Detailed instructions for use are in the User's Guide.

[. . . ] Various data processing and calculation functions are performed automatically. Lower system construction cost Higher measurement accuracy Shorter measurement time Four types of monitor screens Measurement data can be displayed on 4 types of monitor screens. These screens enable analysis and evaluation of measurement data from various viewpoints. Profile monitor Time-series change of profile (data on cross section height) can be checked on a 3D gray scale image. Image monitor Both measurement data and profile image can be checked at the same time. Digital monitor Two or more measurement data can be checked at the same time. Trend monitor Time-series change of measurement data can be checked. B-46 Displacement sensors / Width-measuring Sensors System configuration Power Supply Synchronization Sensor Console Z300-KP (cable length: 2 m) Linear Sensor Controller K3AS Controller Z500-MC10E Z500-MC15E Programmable Controller Sensor Extension Cable Z309-SC1R (cable length: 1. 5 m, 3 m, 6 m, 8 m or 13 m) Monitor Cable F150-VM (cable length: 2 m) BNC Jack (Provided with F150-VM) Monitor Liquid Crystal Monitor F150-M05L (pin input) Sensor Z500-SW2T (cable length: 2 m) Z500-SW6 (cable length: 0. 5 m) Z500-SW17(cable length: 2 m) (Up to 2 Sensors can be connected. ) Ordering Information Name Sensor Item Model Z500-SW2T Z500-SW6 Z500-SW17 Controller Console Liquid Crystal Monitor Sensor Extension Cable Monitor Cable Z500-MC10E Z500-MC15E Z300-KP F150-M05L Z309-SC1R (See note) F150-VM Cable length: 2 m Cable length: 2 m Cable length: 0. 5 m Cable length: 2 m NPN input/output PNP input/output ---- ---- Cable length: 1. 5 m, 3 m, 6 m, 8 m or 13 m Remarks Note: Specify the required cable length when ordering. Z500 B-47 Z500 Rating/Performance Sensor Z500-SW2T/-SW6/-SW17 Model Z500-SW2T Diffuse reflection Mirror reflection Z500-SW6 Diffuse reflection Mirror reflection Z500-SW17 Diffuse reflection Mirror reflection Measurement mode Item Distance to measurement center Measurement range 5. 2 mm ±0. 8 mm 20 mm (with beam cover 50 mm attached: 16 mm) ±5 mm 44 mm ±4 mm 100 mm ±20 mm 94 mm ±16 mm Light source Visible-light semiconductor laser Visible-light semiconductor laser (See note 10) (Wavelength 658 nm, 15 mW max. , Class 3B) (Wavelength 650 nm, 1 mW max. , Class 2) Reference distance: 20 µm × 4 mm TYP. (Measurement region: 2 mm) ±0. 1 %F. S. (See note 3) 9. 94 ms Lit while laser is ON. [. . . ] The linearity varies with the type of workpiece. Error with respect to the theoretical line representing the displacement output for measurement of OMRON standard white alumina ceramics. The linearity varies with the type of workpiece. Z500-SW17 120 mm Digital output 80 mm 80 mm ±0. 1 % max. Distance 120 mm 5 . Displacement conversion value for peak-to-peak of displacement output. These figures are for measurement of OMRON standard quartz glass (mirror reflec- B-48 Displacement sensors / Width-measuring Sensors tion mode) or OMRON standard SUS blocks (diffuse reflection mode) at the measurement center. In strong magnetic fields, it may not be possible to maintain resolution performance characteristics. These figures are for when the Sensor is connected to the Z500-MC10E/MC15E, the average number of measurements is 16. Measurement data are sent to PC via RS-232C cable for calculation of their average values. Displacement conversion value for peak-to-peak of displacement output (for measurement of OMRON standard white alumina ceramic at the measurement center). In strong magnetic fields, it may not be possible to maintain resolution performance characteristics. With the Z500-MC10E/MC15E, at an average number of measurements of 64. Measurement data are sent to PC via RS-232C cable for calculation of their average values. Value for measurement with the space between the Sensor and the workpiece (white alumina ceramic) secured with an aluminum jig. 10. Higher power laser type (Class 3B) is also available. For further information, please contact us. Z500 B-49 Z500 Controller Z500-MC10E/MC15E Model Item Input/Output Type Number of Sensors that can be mounted 2 Number of scenes Light intensity tracking function Measurement item Region specification PerforTrigger function mance specifications Results output 16 Automatic (The light intensity tracking range can be specified)/Fixed (Select from 31 stages)/ Multiple (The light intensity range can be specified) Select from the following 8 types: Height, Step: 2 pts, Step: 3 pts, Edge position, With, Edge center, Peak/Bottom, Define Region specification of line beam and displacement direction is possible. Free/External 1/External 2/Auto · Judgment output RS-232C output Terminal block output · Measurement value output (measurement value) RS-232C output Analog output 11 input points: TRIGGER, LD-OFF, RESET, D10 to D17 21 output points: DO0 to DO19, GATE 1CH (for pin jack or overscan monitor) The full scale for output can be divided into a maximum of 40, 000 gradations. Resolution (See note): 0. 25 mV (±5 V), 0. 4 µA (4 to 20 mA) 21. 6 to 26. 4 VDC 1 A max. between all DC external terminals and GR terminal (100 VDC megger) (with internal surge absorber removed) 1000 VAC, 50/60 Hz between all DC external terminals and GR terminal (with internal surge absorber removed) 10 mA max. 1500 Vp-p; pulse width: 0. 1 µs/1 µs, Rising edge: 1-ns pulse 10 to 150 Hz (double amplitude: 0. 1 mm) for 8 min. each in X, Y, and Z directions 200 m/s2, 3 times each in 6 directions Operating: 0 to +50 °C, Storage: -15 to +60 °C (with no icing or condensation) Operating and storage: 35 to 85 %RH (with no condensation) No corrosive gases Ground the Z500's ground terminal to less than 100 . [. . . ] Do not expose your eyes directly to the laser radiation. Ensure that the laser beam path is terminated during use. If a mirror or shiny surface is positioned in the laser beam path, ensure that the reflected beam path is also terminated. If the Unit must be used without terminating the laser beam path, position the laser beam path so that it is not at eye level. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON Z500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON Z500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag