User manual OMRON ZS-DSU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON ZS-DSU. We hope that this OMRON ZS-DSU user guide will be useful to you.

Lastmanuals help download the user guide OMRON ZS-DSU.


Mode d'emploi OMRON ZS-DSU
Download
Manual abstract: user guide OMRON ZS-DSU

Detailed instructions for use are in the User's Guide.

[. . . ] Z210-E2-01 ZS-DSU (Ver 1. 0) Smart Sensors Data Storage Unit USER'S MANUAL Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 , Í, ¶, ß, É `æ 1 Í `æ 2 Í `æ 3 Í `æ 4 Í Introduction APPLICATION CONSIDERATIONS (Please Read) Section 1 FEATURES Section 2 INSTALLATION & CONNECTION Section 3 SETUP Section 4 EXTERNAL I/O Section 5 APPLICATION SETTING EXAMPLES Section 6 APPENDIX User's Manual Smart Sensor Data Storage Unit ZS-DSU Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] FUN Mode-[LOGGING]-[TRIGGER]-[START]-[WINDOW] Setting SOURCE UPPER LOWER MODE Description Select the source to be used as the logging start trigger. Range: SourceA to J Sets the upper limit value of the specified range. Range: -999. 999 to 999. 999 Sets the lower limit value of the specified range. Range: -999. 999 to 999. 999 Select either of the measured value inside or outside the specified range is to be used as the start trigger. Range: IN, OUT (default: IN) Section3 SETUP Measured value Specified range At IN At OUT DELAY Logging start Logging start Set the delay time when you want to start logging a little before or a little after the start trigger. Range: -9999 to 9999 (ms) (default value: 0 ms) -9999ms Delay time +9999ms Measured value Specified range At -9999ms At 9999ms Start trigger Logging start Logging start User's Manual ZS-DSU 3-19 Section3 Setting the Logging Conditions I/O RESULT Set this item when you want to apply a trigger by the input result (e. g. trigger input) from a controller on a specific CH assigned as the source or by the output result (HIGH/ PASS/LOW/, etc. ). FUN Mode-[LOGGING]-[TRIGGER]-[START]-[I/O] Setting SOURCE I/O SEL Description Select the source to be used as the logging start trigger. Range: SourceA to J Select which I/O signal on the channel assigned as the selected source is to be used as the start trigger. Range: IN0 to IN3, OUT0 to OUT4 Sets the change in state of the signal, from ON to OFF or from OFF to ON, to be taken as the trigger. Range: OFF ON, ON OFF (default value: OFF ON) Section3 SETUP ACTIVE ON OFF At OFF At ON ON Logging start OFF Logging start DELAY Set the delay time when you want to start logging a little before or a little after the start trigger. Range: -9999 to 9999 (ms) (default value: 0 ms) -9999ms Delay time +9999ms Measured value Start trigger At -9999ms At 9999ms Logging start Logging start 3-20 ZS-DSU User's Manual Section3 Setting the Logging Conditions HOUR This item is for setting the time (hours, minutes, seconds) that logging is to be started. The system clock must be set on the ZS-DSU beforehand. Setting the System Clock p. 3-34 FUN Mode-[LOGGING]-[TRIGGER]-[END]-[HOUR] <When set at 9:00:00> 8:00 8:30 9:00 9:30 Section3 SETUP Logging start Setting the end trigger Set the conditions for ending logging. Select one of "BUTTON, EXT, DATA, WINDOW, I/O, HOUR, TIME, QUANT" as the end trigger. When [LOGING]-[TRIGGER]-[END] is selected, the first No. that is blinking indicates the current end trigger. The default value is [BUTTON]. BUTTON This setting item is for inputting the end trigger by key operation on the ZS-DSU. Logging ends when the UP key is pressed. FUN Mode-[LOGING]-[TRIGGER]-[END]-[BUTTON] The UP key is pressed Logging end User's Manual ZS-DSU 3-21 Section3 Setting the Logging Conditions EXT INPUT SLOPE This item is for setting the external input signal as the logging end trigger. FUN Mode-[LOGGING]-[TRIGGER]-[END]-[EXT] Setting EDGE Description Select at which timing, ON or OFF, of the timing signal that logging is to end. Range: OFF ON, ON OFF (default value: OFF ON) Delays end of logging by about 1. 2 ms at most from input of the external trigger. Section3 SETUP Timing input At OFF At ON ON OFF ON Logging end OFF Logging end 1. 2ms 1. 2ms DATA SLOPE This item is for setting the change in the state of the data (measured value) as the logging end trigger. When the data falls above or below this preset trigger level value, this is taken to be the end trigger. FUN Mode-[LOGING]-[TRIGGER]-[END]-[DATA] Setting ASSIGN EDGE Description Select the source to be used as the logging end trigger. [. . . ] Answer This changes according to the number of assigned sources and mode. p. 3-26 Can I use third-party Memory Cards?Operation of some types has been verified. Contact your OMRON representative. Glossary Term Memory Card CSV file Explanation Storage media for saving logging data CompactFlash is used on the Data Storage Unit. An abbreviation for text delimited with commas. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZS-DSU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZS-DSU will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag