User manual ONGA PPP POOL PUMP RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ONGA PPP POOL PUMP RANGE. We hope that this ONGA PPP POOL PUMP RANGE user guide will be useful to you.

Lastmanuals help download the user guide ONGA PPP POOL PUMP RANGE.


Mode d'emploi ONGA PPP POOL PUMP RANGE
Download
Manual abstract: user guide ONGA PPP POOL PUMP RANGE

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual PPP Pool Pump Range Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of the product. An earth leakage or residual current protection device must be fitted to all installations. L300086- 1104 20 1 Onga Product Warranty (Continued) Relax - you've bought an Onga . . . Congratulations on your decision to purchase an Onga product. Onga is one of the best known brands in its field, with a proud local and International reputation. Onga is a brand for reliability, value for money and technological innovation. You will find Onga product wherever people need to move water in 3 broad markets covering: Technologically advanced solutions for moving and treating water in the Home, Garden, Pool and Spa. How to get service: In Australia please contact 1800 664 266 In New Zealand please contact 0800 664 269 Claims under this warranty must give evidence of date of purchase, model and serial number of the product and the claimants name, address and telephone number. [. . . ] Debris or trash that collects in basket will choke off water flow through the pump. Follow instructions below to clean basket: 1. Switch off power to pump, close valves in suction and discharge, and release all pressure from system before proceeding. If necessary, undo drain plug to reduce lid vacuum. Do not use a hammer or similar tool to loosen the lid. If the lid is too tight to undo by hand, use a lever such as a board or long screwdriver positioned between the lid lugs and turn counterclockwise. Ensure all holes in basket are clear, flush basket with water and replace in bowl assembly with large opening at pipe connection port (between ribs provided). If basket is replaced backwards the lid will not fit on casing & bowl. To clean transparent cover, use water and neutral soap only. Clean and inspect lid o'ring; reinstall on bowl assembly. Clean O'ring groove on bowl assembly and replace lid. To help keep cover from sticking, tighten hand tight only. Prime pump (refer priming instructions). Installation (Continued) NOTICE: If the pump is not provided with a supply cord and a plug, or with other means of disconnection from the supply having a contact separation of at least 3mm in all poles, such means for disconnection must be incorporated in the fixed wiring. NOTICE: Use Teflon tape for making all threaded connections to the pump. Do not use pipe dope (glue) as this will cause stress fractures in the pump. Teflon Taping Instructions: Use only new or clean PVC pipe fittings. Wrap male pipe threads with one to two layers (or a sufficient number of layers) of Teflon tape. If leaks occur, remove pipe, clean off old tape, rewrap as previously with one to two additional layers of tape and remake the connection. NOTICE: Support all piping connected with pump. Piping: To reduce friction losses use at least 2" (50mm) PVC pipe. To avoid stress on the pump, support both suction and discharge pipes independently. Place these supports as close to the pump as possible. [. . . ] All suction outlets must have correctly installed, screw-fastened covers in place. Testing and Certification Suction outlet covers must have been tested by a nationally recognised testing laboratory and found to comply with the latest AS1926. 3-2003 Standard or the relevant local standard. Outlets Per Pump Provide at least two hydraulically balanced main drains, with covers, for each swimming pool pump suction line. The centers of the main drains (suction fittings) must be at least 800mm apart. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ONGA PPP POOL PUMP RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ONGA PPP POOL PUMP RANGE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag